PRODUCT MANUAL NAC3FPX-TRUE1 | powerCON TRUE1 Chassis APPLIANCE OUTLET

1 APPLICATION & SAFETY INSTRUCTION

IP 65 & IP 67 RATED & airtightness

APPLICATION:

POWER IN

APPLIANCE INLET NAC3MPX-TRUE1

[Image description: A black electrical connector with a blue locking collar, labeled NAC3MPX-TRUE1.]

Compatible Connectors:

  • CONNECTOR: NAC3F-TRUE1-S, NAC3F-TRUE1-L, NAC3FX-W-TOP, NAC3FX-W-TOP-L
  • PLUG CONNECTOR: NAC3M-TRUE1-S, NAC3M-TRUE1-L, NAC3MX-W-TOP, NAC3MX-W-TOP-L

POWER OUT

APPLIANCE OUTLET NAC3FPX-TRUE1

[Image description: A black electrical connector with a blue locking collar, labeled NAC3FPX-TRUE1. This is the main product.]

Compatible Connectors:

  • CONNECTOR: NAC3F-TRUE1-S, NAC3F-TRUE1-L, NAC3FX-W-TOP, NAC3FX-W-TOP-L
  • PLUG CONNECTOR: NAC3M-TRUE1-S, NAC3M-TRUE1-L, NAC3MX-W-TOP, NAC3MX-W-TOP-L

POWER IN / POWER OUT Combination

APPLIANCE INLET / APPLIANCE OUTLET NAC3PX-TRUE1

[Image description: A black electrical connector with a blue locking collar, labeled NAC3PX-TRUE1, showing both inlet and outlet functionality.]

Compatible Connectors:

  • CONNECTOR: NAC3F-TRUE1-S, NAC3F-TRUE1-L, NAC3FX-W-TOP, NAC3FX-W-TOP-L
  • PLUG CONNECTOR: NAC3M-TRUE1-S, NAC3M-TRUE1-L, NAC3MX-W-TOP, NAC3MX-W-TOP-L

2 ASSEMBLY INSTRUCTION

Step 1: Wiring

[Diagram description: A diagram showing how to wire a connector. It highlights flat tabs for FASTON® connectors measuring 6.35 mm x 0.8 mm (1/4" x 0.03"). The diagram also shows 'N' and 'L' terminals for neutral and live connections.]

NOTE: To be only used flat connectors according to IEC 61210.

Step 2: Assembly

A Insert the receptacle from the front into the panel.

B Position the screw and fasten it. (Recommended screw look at Point 3.b)

C ⚠️ ATTENTION: Tightening torque MA = 40 - 50 Ncm. POZIDRIV® #1

ℹ️ NOTE: Lubricate sealing lip with silicon from time to time.

[Image description: A diagram illustrating the assembly process. Part A shows inserting the connector into a panel. Part B shows fastening a screw. Part C shows a warning symbol for tightening torque and a POZIDRIV #1 screwdriver icon.]

3 Additional information

A Panel Cutout (Rear Side)

Rz ≤ 16

[Diagram description: A circular panel cutout diagram with dimensions. The diameter is specified as ≥ Ø 28.7 mm [1.13"]. Two smaller holes for screws are shown with a diameter of > Ø 3.2 mm [.126"]. The center-to-center distance for the screw holes is 24.4±0.1 mm [.961±0.003"].]

B Recommended screw

M3 stainless steel countersunk type

[Diagram description: A diagram of a countersunk screw with a length of 5.3-6.0 mm [.201 -0.236"] and an angle of 90°.]

2x ? Screws

4 Application and Safety Instructions

A Assembly

B Application

C Operation

D Cleaning

E Damages

5 Compatibility information

The products are suitable for use with the products listed below. When used with other products, the suitability and safety must be assessed before commissioning and appropriate safety measures must be taken if necessary.

Compatibility between Chassis Outlets and Connectors
NAC3FPX-TRUE1NAC3MPX-TRUE1NAC3PX-TRUE1
NAC3F-TRUE1-S
NAC3F-TRUE1-L
Not applicableCertified acc. to:
UL 60320-1
EN IEC 60320-1
Certified acc. to:
UL 60320-1
EN IEC 60320-1
NAC3M-TRUE1-S
NAC3M-TRUE1-L
NAC3FX-W-TOP
NAC3FX-W-TOP-L
Certified in combination with
NAC3MPX-TOP & NAC3PX-TOP
Not applicableCertified acc. to:
UL 60320-1
EN IEC 60320-1
NAC3MX-W-TOP
NAC3MX-W-TOP-L
Certified in combination with
NAC3FPX-TOP & NAC3PX-TOP
Tested acc. to:
UL 60320-1
EN IEC 60320-1
Tested acc. to:
UL 60320-1
EN IEC 60320-1
Tested acc. to:
UL 60320-1
EN IEC 60320-1
IP Protection Class by Combination
NAC3FPX-TRUE1NAC3MPX-TRUE1NAC3PX-TRUE1
NAC3M-TRUE1-S
NAC3M-TRUE1-L
IP65 / IP67Not applicableIP65 / IP67
NAC3F-TRUE1-S
NAC3F-TRUE1-L
Not applicableIP65 / IP67IP65 / IP67
NAC3MX-W-TOP
NAC3MX-W-TOP-L
IP65Not applicableIP65
NAC3FX-W-TOP
NAC3FX-W-TOP-L
Not applicableIP65IP65
ultimate POWER CORDSIP65 / IP 66 / IP67IP65 / IP 66 / IP67IP65 / IP 66 / IP67

A UNMATED CONNECTOR (OPEN SEALING CAP)

[Image description: A diagram showing an unmated connector with an open sealing cap. It indicates the connection to a 'DEVICE' and 'CONTACT CHAMBER'. The IP rating is shown as AIRTIGHT ? IP65 / IP66 / IP67.]

B UNMATED CONNECTOR (CLOSED SEALING CAP)

[Image description: A diagram showing an unmated connector with a closed sealing cap. It indicates the connection to a 'DEVICE' and 'CONTACT CHAMBER'. The IP rating is shown as AIRTIGHT ? IP65 / IP66 / IP67.]

5 More Information on the website

C MATED CONNECTOR

[Image description: A diagram showing a mated connector, with a cable attached. It indicates the connection to a 'DEVICE' and 'CONTACT CHAMBER'. The IP rating is shown as IP65 / IP67.]

For more information, visit: https://www.neutrik.com/en/neutrik/products/powercon-r/powercon-r-true1

Models: NAC3FPX-TRUE1, NAC3FPX-TRUE1 PowerCON TRUE1 Power Output Panel Connector, NAC3FPX-TRUE1, PowerCON TRUE1 Power Output Panel Connector, Power Output Panel Connector, Panel Connector, Connector

PDF preview unavailable. Download the PDF instead.

092-315--neutrik-nac3fpx-true1-user-manual Microsoft: Print To PDF

Related Documents

Preview Neutrik powerCON TRUE1 NAC3FPX-TRUE1 Chassis Appliance Outlet Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 NAC3FPX-TRUE1 chassis appliance outlet, detailing application, safety instructions, assembly, compatibility, and specifications.
Preview Neutrik powerCON TRUE1 NAC3MPX-TRUE1 Chassis Appliance Inlet - Product Manual
Official product manual for the Neutrik powerCON TRUE1 NAC3MPX-TRUE1 chassis appliance inlet connector, detailing application, safety instructions, assembly, compatibility, and technical specifications.
Preview Neutrik powerCON TRUE1 NAC3F-TRUE1-S & NAC3F-TRUE1-L Product Manual
Comprehensive product manual for Neutrik powerCON TRUE1 connectors (NAC3F-TRUE1-S, NAC3F-TRUE1-L), detailing application, safety instructions, assembly, disassembly, operation, cleaning, damages, and compatibility. Features IP65/IP67 rating and compliance with IEC, UL, and CSA standards.
Preview Neutrik powerCON TRUE1 NAC3F-TRUE1-S & NAC3F-TRUE1-L Product Manual
Comprehensive product manual for Neutrik powerCON TRUE1 NAC3F-TRUE1-S and NAC3F-TRUE1-L appliance couplers, detailing application, safety instructions, assembly, disassembly, and operation.
Preview Neutrik powerCON TRUE1 NAC3M-TRUE1-S/L Product Manual and Safety Guide
Comprehensive product manual for Neutrik powerCON TRUE1 connectors (NAC3M-TRUE1-S, NAC3M-TRUE1-L), covering application, safety instructions, assembly, disassembly, compatibility, and technical specifications.
Preview Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L Cable Connector Product Manual
Detailed product manual for the Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L appliance coupler, covering application instructions, assembly, disassembly, safety guidelines, and technical specifications.
Preview Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP appliance coupler, detailing application, safety instructions, assembly, disassembly, and operation.
Preview Neutrik TRUE1 2+PE powerCON Connector (Male) NT-NAC3M-TRUE1-S Specifications
Detailed specifications for the Neutrik TRUE1 2+PE powerCON Connector (Male), model NT-NAC3M-TRUE1-S. Features include heavy-duty sealed design, UV resistance, IP65/IP67 rating, and breaking capacity (CBC). Covers physical, electrical, mechanical, and environmental characteristics.