PRODUCT MANUAL powerCON TRUE1 NAC3F-TRUE1-S NAC3F-TRUE1-L

1 APPLICATION & SAFETY INSTRUCTION

IP 65 & IP 67 RATED

APPLICATION:

  • The powerCON TRUE1 system is certified as appliance couplers with breaking capacity according to IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1.
  • It serves to supply power to an appliance and from an appliance to other equipment.
  • To be installed by qualified person only.
  • Appliance couplers acc. to IEC 60320-1 are suitable to be used in cord sets and interconnection cord sets acc. to IEC 60799.

Product Categories:

  • POWER IN: APPLIANCE INLET NAC3MPX-TOP, NAC3MPX-WOT-TOP, NAC3MPX-TRUE1
  • POWER OUT: APPLIANCE OUTLET NAC3FPX-TOP, NAC3FPX-WOT-TOP, NAC3FPX-ST-TOP, NAC3FPX-TRUE1
  • POWER IN / POWER OUT Combination: APPLIANCE INLET / APPLIANCE OUTLET NAC3PX-TOP, NAC3PX-TRUE1

Connectors:

  • CONNECTOR: NAC3F-TRUE1-S, NAC3F-TRUE1-L
  • PLUG CONNECTOR: NAC3M-TRUE1-S, NAC3M-TRUE1-L

Compliance:

Products are in compliance with:

StandardRatingConductor cross section
IEC 60320-1, EN IEC 60320-116A 250V AC1.5 - 2.5 mm²
UL 60320-1, CSA C22.2 No. 60320-120A 250V AC14 - 12 AWG

CABLE LIST:

Approved cables3 x 1.5 mm²3 x 2.5 mm²
H07RN-F-S-L
H05VV-F-S-S
Approved cables14/3 AWG12/3 AWG
SOOW-L-L
SJOOW-S-L

2 ASSEMBLY INFORMATION

A. Cable Preparation and Insertion:

Place the bushing (1) and chuck (2) over the cable. Important: Chuck and Bushing cannot be placed over the cable after the assembly of the insert. For easier assembly, please use a cable lubricant.

Prepare cable as shown, stripping 24 mm [0.94"] and exposing 9 mm [0.35"] of conductor. This applies to IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1 standards.

B. Contact Clamping:

Slide the cable into the contacts and clamp with the screw using a Torx size T8. Torque Value: 0.7 Nm (6.2 inch pound / 0.52 lb.ft).

Typical Wiring:

  • IEC/EN: L (brown), N (blue), Ground (green/yellow).
  • UL/CSA: L (black), N (white), Ground (green).

C. Insert and Housing Assembly:

Position chuck (1) on insert (2). Slide insert (2) with chuck (1) together into housing (3). Important: Align the chuck by positioning the nose into the keyway. Slide bushing (4) over chuck (1). Push and turn simultaneously.

2 ASSEMBLY INFORMATION (Continued)

D. Final Tightening:

Hold the connector with the NEUTRIK tool (5) HTLACA and tighten bushing with the NEUTRIK tool (6) HTLACB as shown. For exact mounting, use a torque wrench with a 27 mm (1 1/8 inch) hex bit (7) and tighten to 2.5 Nm (22 inch pound / 1.8 lb-ft). Important: Ensure the black O-ring is covered by the bushing to achieve IP protection (8).

3 FOR DISASSEMBLY

1. Use the Neutrik tool HTLACB. 2. Position the tool on the surfaces and open the clamping sleeve.

4 SAFETY INFORMATION

CAUTION:

To ensure protection category, do not expose the connection to bending forces (e.g., do not attach loads to the cable, avoid free-dangling cable windings). [Force]

SAFETY WARNING:

For safety reasons, appliance couplers must be replaced if any parts are broken or show excessive wear and tear.

5 Application and Safety Instructions

A. Assembly:

  • Ensure the use of appropriate personal protective equipment during assembly.
  • Neutrik components must only be assembled with designated and specified components.
  • Replacement parts are suitable only when used in combination with designated components. Product characteristics are guaranteed only in the intended combination.

B. Application:

  • The product is exclusively intended for installation in electronic equipment or similar devices.
  • The product is not intended for use in medical applications.
  • The product is not intended for use in potentially explosive or flammable environments.
  • Appliance couplers are not intended for use as climbing aids. Caution: Electrical hazards!
  • Rated values are marked on the product and the smallest packaging unit.
  • Ensure connectors are plugged in or protected against moisture with a suitable protective cap in potentially humid environments.

C. Operation:

  • The safety of this product was evaluated according to standard specifications under laboratory conditions.
  • After installation in an electronic device or similar, product safety in the intended application must be ensured by the respective party involved.
  • Before plugging in, check the contact area for dry surfaces.
  • Product surfaces may cause burns at elevated ambient temperatures. Ensure the use of appropriate protective equipment.
  • The customer is responsible for ensuring that the device is de-energized when plugged in with the male contact.
  • Neutrik Products are only allowed to be used with compatible products from Neutrik Group brands.
  • The product is unsuitable for use by vulnerable consumers.
  • Connectors and plug connectors complying with IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1 are suitable for normal use at ambient temperatures not normally exceeding +40 °C, but their average over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of –5 °C.

D. Cleaning:

  • Clean only with dry and lint-free materials or compressed air.
  • The product must not be cleaned while under load. The product may only be cleaned while it is not connected to any voltage and without the use of cleaning agents.

E. Damages:

  • Handle products with care.
  • In case of visible damages, check the suitability of the product for use.
Models: NAC3F-TRUE1-S, NAC3F-TRUE1-L, NAC3 Series Connector, NAC3 Series, Connector

PDF preview unavailable. Download the PDF instead.

BDA 697 V6 - powerCON TRUE1 Cable Connector NAC3F-TRUE1-S & NAC3F-TRUE1-L Corel PDF Engine Version 26.1.0.143 CorelDRAW 2025

Related Documents

Preview Neutrik powerCON TRUE1 NAC3M-TRUE1-S/L Product Manual and Safety Guide
Comprehensive product manual for Neutrik powerCON TRUE1 connectors (NAC3M-TRUE1-S, NAC3M-TRUE1-L), covering application, safety instructions, assembly, disassembly, compatibility, and technical specifications.
Preview Neutrik powerCON TRUE1 NAC3F-TRUE1-S & NAC3F-TRUE1-L Product Manual
Comprehensive product manual for Neutrik powerCON TRUE1 connectors (NAC3F-TRUE1-S, NAC3F-TRUE1-L), detailing application, safety instructions, assembly, disassembly, operation, cleaning, damages, and compatibility. Features IP65/IP67 rating and compliance with IEC, UL, and CSA standards.
Preview Neutrik powerCON TRUE1 NAC3FPX-TRUE1 Chassis Appliance Outlet Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 NAC3FPX-TRUE1 chassis appliance outlet, detailing application, safety instructions, assembly, compatibility, and specifications.
Preview Neutrik powerCON TRUE1 Chassis Appliance Outlet NAC3FPX-TRUE1 Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 chassis appliance outlet (NAC3FPX-TRUE1), detailing application, safety instructions, assembly, compatibility, and specifications. Features IP65/IP67 rating for robust power connections.
Preview Neutrik powerCON TRUE1 NAC3MPX-TRUE1 Chassis Appliance Inlet - Product Manual
Official product manual for the Neutrik powerCON TRUE1 NAC3MPX-TRUE1 chassis appliance inlet connector, detailing application, safety instructions, assembly, compatibility, and technical specifications.
Preview Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP appliance coupler, detailing application, safety instructions, assembly, disassembly, and operation.
Preview Neutrik powerCON TRUE1 TOP NAC3MX-W-TOP Assembly Instructions
Detailed assembly instructions for the Neutrik powerCON TRUE1 TOP NAC3MX-W-TOP connector, including application instructions, connector assignment, and safety information.
Preview Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L Cable Connector Product Manual
Detailed product manual for the Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L appliance coupler, covering application instructions, assembly, disassembly, safety guidelines, and technical specifications.