1 APPLICATION & SAFETY INSTRUCTION
IP 65 & IP 67 RATED
APPLICATION: The powerCON TRUE1 system is certified as appliance couplers with breaking capacity according to IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1. It serves to supply power to an appliance and from an appliance to other equipment. To be installed by qualified person only. Appliance couplers according to IEC 60320-1 are suitable to be used in cord sets and interconnection cord sets according to IEC 60799.
Connector Types
POWER IN: APPLIANCE INLET models include NAC3MPX-TOP, NAC3MPX-WOT-TOP, NAC3MPX-TRUE1. These use CONNECTOR type NAC3F-TRUE1-S, NAC3F-TRUE1-L.
POWER OUT: APPLIANCE OUTLET models include NAC3FPX-TOP, NAC3FPX-WOT-TOP, NAC3FPX-ST-TOP, NAC3FPX-TRUE1. These use PLUG CONNECTOR type NAC3M-TRUE1-S, NAC3M-TRUE1-L.
POWER IN / POWER OUT Combination: APPLIANCE INLET / APPLIANCE OUTLET models include NAC3PX-TOP, NAC3PX-TRUE1. These use CONNECTOR type NAC3F-TRUE1-S, NAC3F-TRUE1-L and PLUG CONNECTOR type NAC3M-TRUE1-S, NAC3M-TRUE1-L.
Compliance, Ratings, and Cable Specifications
Products are in compliance with: | IEC 60320-1 EN IEC 60320-1 | UL 60320-1 CSA C22.2 No. 60320-1 |
Ratings: | 16A 250V AC | 20A 250V AC |
Conductor cross section: | 1.5 - 2.5 mm² | 14 - 12 AWG |
CABLE LIST
Approved cables: | 3 x 1.5 mm² | 3 x 2.5 mm² |
H07RN-F | -S | -L |
H05VV-F | -S | -S |
Approved cables: | 14/3 AWG | 12/3 AWG |
SOOW | -L | -L |
SJOOW | -S | -L |
2 ASSEMBLY INFORMATION
Step A: Cable Preparation and Chuck/Bushing Placement
Place the bushing (1) and chuck (2) over the cable. Important: Chuck and Bushing cannot be placed over the cable after the assembly of the insert. For easier assembly, use a cable lubricant.
Prepare cable as shown. This involves stripping the outer jacket to 24 mm and the insulation to 9 mm.
Step B: Contact Insertion and Wiring
Slide the cable into the contacts and clamp with the screw using Torx size T8. Torque Value: 0.7 Nm (6.2 inch pound / 0.52 lb.ft).
Typical Wiring
IEC 60320-1 EN IEC 60320-1 | UL 60320-1 CSA C22.2 No. 60320-1 | |
N | blue | black |
L | brown | white |
Ground | green/yellow | green |
Step C: Insert and Housing Assembly
Position chuck (1) on insert (2). Slide insert (2) with chuck (1) together into housing (3). Important: Align the chuck by positioning the nose into the keyway. Slide bushing (4) over chuck (1). Push and turn simultaneously.
3 FOR DISASSEMBLY
Use the Neutrik tool HTLACB. Position the tool on the surfaces and open the clamping sleeve.
4 SAFETY INFORMATION
CAUTION
To ensure protection category, do not expose the connection to bending forces (e.g., do not attach loads to the cable, no free-dangling cable windings, etc.).
SAFETY WARNING
For safety reasons, appliance couplers must be replaced in case of any broken parts or excessive wear and tear.
5 Application and Safety Instructions
A Assembly
- When assembling and processing the product, ensure the use of appropriate personal protective equipment.
- Neutrik components must only be assembled with designated and specified components.
- Replacement parts are suitable only when used in combination with the designated components. The product's characteristics are guaranteed only in the intended combination.
B Application
- The product is exclusively intended for installation in electronic equipment or similar devices.
- The product is not intended for use in medical applications.
- The product is not intended for use in potentially explosive or flammable environments.
- Appliance couplers are not intended for use as climbing aids. Caution: Electrical hazards!
- For indoor use only.
- Rated values are marked on the product and the smallest packaging unit.
C Operation
- The safety of this product was evaluated according to standard specifications under laboratory conditions.
- After installation in an electronic device or similar, the product safety in the intended application must be ensured by the respective party involved.
- Before plugging in, check the contact area for dry surfaces.
- Product surfaces may cause burns at elevated ambient temperatures. Ensure the use of appropriate protective equipment.
- The customer is responsible for ensuring that the device is de-energized when plugged in with male contact.
- Neutrik Products are only allowed to use with compatible products from Neutrik Group brands.
- The product is unsuitable for use by vulnerable consumers.
- Connectors and plug connectors complying with this part of IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1 are suitable for normal use at ambient temperatures not normally exceeding +40 °C, but their average over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of -5 °C.
D Cleaning
- Clean only with dry and lint-free materials or compressed air.
- The product must not be cleaned while under load. The product may only be cleaned while it is not connected to any voltage and without the use of cleaning agents.
E Damages
- Handle products with care.
- In case of visible damages, check the suitability of the product for use.
6 Compatibility information
The products are suitable for use with the products listed below. When used with other products, the suitability and safety must be assessed before commissioning and appropriate safety measures must be taken if necessary.
Compatibility Matrix
NAC3FPX-TRUE1 | NAC3MPX-TRUE1 | NAC3PX-TRUE1 | |
NAC3F-TRUE1-S NAC3F-TRUE1-L | Not applicable | Certified acc. to: UL 60320-1 EN IEC 60320-1 | Certified acc. to: UL 60320-1 EN IEC 60320-1 |
NAC3M-TRUE1-S NAC3M-TRUE1-L | Certified acc. to: UL 60320-1 EN IEC 60320-1 | Tested acc. to: UL 60320-1 EN IEC 60320-1 | Tested acc. to: UL 60320-1 EN IEC 60320-1 |
NAC3FX-W-TOP NAC3FX-W-TOP-L Certified in combination with NAC3MPX-TOP & NAC3PX-TOP | Not applicable | Tested acc. to: UL 60320-1 EN IEC 60320-1 | Tested acc. to: UL 60320-1 EN IEC 60320-1 |
NAC3MX-W-TOP NAC3MX-W-TOP-L Certified in combination with NAC3FPX-TOP & NAC3PX-TOP | Certified acc. to: UL 60320-1 EN IEC 60320-1 | Not applicable | Tested acc. to: UL 60320-1 EN IEC 60320-1 |
IP Protection Class
NAC3M-TRUE1-S NAC3M-TRUE1-L | NAC3F-TRUE1-S NAC3F-TRUE1-L | NAC3FPX-TRUE1 | NAC3MPX-TRUE1 | NAC3PX-TRUE1 | NAC3FPX-TOP | NAC3MPX-TOP | NAC3PX-TOP | |
NAC3FPX-TRUE1 | IP65/IP67 | IP65/IP67 | Not applicable | Not applicable | ||||
NAC3MPX-TRUE1 | Not applicable | Not applicable | IP65/IP67 | IP65/IP67 | IP65/IP67 | Not applicable | Not applicable | |
NAC3PX-TRUE1 | IP65/IP67 | IP65/IP67 | IP65/IP67 | IP65/IP67 | IP65/IP67 | IP65/IP67 | IP65/IP67 | IP65/IP67 |
NAC3FPX-TOP | IP65 | IP65 | Not applicable | Not applicable | IP65 | |||
NAC3MPX-TOP | Not applicable | Not applicable | Not applicable | IP65 | IP65 | |||
NAC3PX-TOP | IP65 | IP65 | IP65 | IP65 | IP65 |
MATED CONNECTOR SCF-TRUE1-01: IP65/IP67. MATED CONNECTOR SCNAC-FX: IP65.