Fridababy Quick-Read Rectal Thermometer

Tush temp checks in 10 secs.

USER MANUAL

BUTT FIRST, LET ME TAKE A TEMP

Fevers and newborns are not a good mix. Knowing their temp, and knowing it quickly, is. The Quick-Read Rectal Thermometer gives you fast and accurate rectal temperature readings in just 10 seconds. Safe flexible tip and stopper make it parent-proof.

Manufactured for Fridababy LLC, Miami, FL 33137

Love it? Leave a review fridababy.com. Thermometer questions? fussbuster@fridababy.com.

Directions

Method: Rectal

Normal Temperature: 97.3°F - 100.4°F

Fever Range: 100.4°F +

For Rectal Use:

The American Academy of Pediatrics (AAP) recommends that for at least the first year of baby's life (though up to three is best), temp checks should only be done rectally.

  • Before inserting the thermometer, lubricate the silver tip. We suggest coconut oil or other natural lubricants.
  • Lift baby's legs and gently insert the thermometer tip up to the insertion stopper.
  • Do not insert past the point where you feel resistance (usually from baby's lower cheeks).

Call your child's doctor right away if your child has a fever and:

  • Is younger than 3 months (12 weeks) and has a temperature of 100.4°F (38.0°C) or higher.
  • If, at any age, the fever rises above 104°F (40°C) repeatedly.

Operating Instructions

  1. Press the Power Button to turn the thermometer on.
  2. Your last temperature reading will show on the LCD screen.
  3. You'll see "---" [displaying dashes] and either F° or C° [Fahrenheit/Celsius indicator] on the top right of the screen. (See below to CHANGE UNIT.)
  4. Ensure you are in the correct unit settings.
  5. Taking baby's temperature with an 10-Second reading: Insert the thermometer into the rectum. Screen will show a loading "[loading indicator]" while registering the temperature. The thermometer will beep and flash a temperature reading after 10 seconds.
  6. Wait a minimum of one minute before attempting a new measurement.
  7. Press the Power Button to turn off. This can be done at any point during a reading.
  8. Remember to sanitize the thermometer before and after all readings.

Change Unit

To change from Fahrenheit (°F) to Celsius (°C), turn it on. When the last temp reading flashes, hold the button for 3 seconds. Press button once to scroll to next mode. Once on preferred mode, wait for 3 seconds to confirm selection.

Memory Mode

After a test is complete, press and hold the power button for 3 seconds. The display will show "MEM" [memory mode indicator], entering memory mode. Once in memory mode, press the button once to scroll to the next memory reading. Press and hold the button for three seconds to turn off.

Product Illustration

A digital thermometer with a flexible tip, a digital screen displaying temperature and unit, a power button, and a battery cover. Key components include:

  • Insertion stopper
  • Digital screen (°F or °C)
  • Power Button
  • Battery Cover
  • Flexible tip

Features: BPA-free, Water-resistant, Insertion stopper.

Specifications

SpecificationDetails
TypeDigital Thermometer
Measure Range89.6°F - 109.2°F (32.0°C - 42.9°C) (°C/°F chosen by user)
Accuracy±0.2°F (0.1°C) during 95.9°F~107.6°F (35.5°C~42.0°C) at 64.4°F~82.4°F (18°C~28°C) ambient operating range; + 0.4°F (0.2°C) for other measuring and ambient operating ranges. Procedures for determining accuracy are available upon request. *Accuracy: +/- .2F in laboratory testing as stated
Operating modeDirect Mode
DisplayLiquid crystal display, 3 1/2 digits
MemoryFor storing the last 10 values
BatteryOne 3V DC CR2032 battery
Battery lifeApprox 200 hours
Dimension9.3cm x 3.45cm x 1.8cm (LxWxH)
WeightApprox. 26 grams including battery
Ambient operating rangeTemperature: 41°F-104°F (5°C~40°C); Relative humidity: 15% ~ 95%RH
Storage and transportation conditionTemperature: -4°F~131°F (-20°C~55°C); Relative humidity: 15% ~ 95%RH
Ingress Protection RatingIP 27
ClassificationType BF
Model61-088

Battery Replacement

  1. Replace battery when "[battery low icon]" appears in the lower right corner of LCD display.
  2. Turn battery cover counter-clockwise to remove.
  3. Discard battery lawfully. Replace with new 3V DC button type CR2032, or equivalent.
  4. Slide battery chamber back into place and attach battery cover.

Precaution

The performance of the device may be degraded should one or more of the following occur:

  • Operation outside the manufacturer's stated temperature and humidity range.
  • Storage outside the manufacturer's stated temperature and humidity range.
  • Mechanical shock (for example, drop test) or degraded sensor.
  • Patient temperature is below ambient temperature.
  • Portable and mobile RF communications can affect the device. The device needs special precautions regarding EMC according to the EMC information provided in the accompanying documents.
  • Do not use the device in the MR environment.

Symbol Explanation

  • [DC symbol] Direct Current
  • [Type BF symbol] Type BF Applied Part
  • [consult accompanying documents symbol] Consult Accompanying Documents
  • [batch code symbol] Batch Code
  • [manufacturer symbol] Manufacturer
  • [temperature range symbol] Storage and Transportation Temperature limit: -4°F ~ 131°F (-20°C ~ 55°C)

Cleaning and Disinfection

  • Wipe the thermometer with a soft clean cloth.
  • For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a neutral detergent and wipe thoroughly.
  • Finish by wiping with a soft dry cloth.
  • For disinfection, 75% Ethanol or Isopropyl alcohol can be used.
  • It is recommended that performance should be checked if the device is not performing or after a repair for examination.

Observe the following to prevent damage to the thermometer:

  • Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer.
  • Do not attempt to disinfect the sensing section (tip) of the thermometer by immersing in alcohol or in hot water (water over 122°F/50°C).
  • Do not use ultrasonic washing to clean the thermometer.

Troubleshooting / Error Codes

Performance may be degraded should one or more of the following occur:

  • Operation outside stated temperature and humidity range.
  • Storage outside stated temperature and humidity range.
  • Mechanical shock.
  • Patient temperature is below ambient temperature.
ErrorProblem/CauseSolution
HiThe measured temperature is above 109.2°F (42.9°C).Results are above range; wait several minutes and attempt new measurement.
ErrThe measured temperature is below 89.6°F (32°C).Results are below range; wait one minute and attempt new measurement.
[system error symbol]The system is not functioning properly.Attempt new measurement; if error persists contact Customer Care at fussbuster@fridababy.com.
Dead battery: [battery low icon] flashingCannot be measured.Check battery and replace with a new battery if necessary.

Normal Body Temperature / Fever Indicator

Body temperature can vary from 97°F and 100.0°F and still be considered normal. The medically accepted 'normal' body temperature is 98.6°F. Body temperature is commonly lower upon waking than at any point during the rest of an individual's waking hours. Temperature readings will vary based on the body location point of the reading. Rectal temperature readings between 97°F (36.1°C) and 100.5°F (38.2°C) are considered normal.

A fever is defined as a body temperature that is elevated above the normal for that person. It is important to determine what is normal for an individual before determining if a fever is present. Tracking an individual's temperature on a consistent basis, at the same body site and at the same time every day when the person is well or healthy will help determine an individual's normal temperature.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference; and (2) this device must accept any interference received, including interference that may cause undesirable operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Warning

  • Read instructions thoroughly before using digital thermometer.
  • Choking Hazard: Thermometer battery door and battery may be fatal if swallowed. Do not allow children to use this device without parental supervision.
  • Do not use thermometer in ear. Designed for rectal readings only.
  • Do not place thermometer battery near extreme heat as it may explode.
  • Remove battery from the device for long-term storage.
  • The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the interpretation of results.
  • Do not attempt measurements when the thermometer is wet as inaccurate readings may result.
  • Do not bite the thermometer.
  • Do not attempt to disassemble or repair the thermometer.
  • After each use, disinfect the thermometer.
  • Do not force the thermometer into the rectum.

Battery Disposal

Do not dispose of used batteries in the trash. Consult your local recycling center for the proper way to dispose of batteries in your area. Keep used batteries away from children, pets and excessive heat.

Standards Conformance

This appliance conforms to the following standards:

  • EN 12470-3 - Part 3
  • ISO 80601-2-56 - Part 2-56
  • EN 60601-1-11 - Part 1-11
  • EN 60601-1-2 (EMC)
  • IEC/EN 60601-1 (Safety Standards)
  • ISO 13485 Certified Manufacturing Facility

Contents

  • 1 Thermometer
  • 1 3V Battery (CR2032)
  • 1 Keep-clean case
  • 1 Owner's manual

EMC Information

Portable and mobile RF communications can affect the device. The device needs special precautions regarding EMC according to the EMC information provided in the accompanying documents.

PDF preview unavailable. Download the PDF instead.

Frida Baby Quick-Read Digital Rectal Thermometer ?279058 macOS Version 10.15.2 (Build 19C57) Quartz PDFContext Keynote

Related Documents

Preview Fridababy 3-in-1 True Temp Thermometer User Manual
Comprehensive user manual for the Fridababy 3-in-1 True Temp Thermometer, detailing its features for accurate rectal, oral, and underarm temperature readings, operational instructions, safety warnings, specifications, and troubleshooting tips for parents and caregivers.
Preview Fridababy 3-in-1 True Temp Thermometer User Manual: Accurate Fever Readings
Comprehensive user manual for the Fridababy 3-in-1 True Temp Thermometer, detailing rectal, oral, and underarm temperature readings, features, operation, and troubleshooting.
Preview Fridababy 3-in-1 Thermometer User Manual
User manual for the Fridababy 3-in-1 Ear, Forehead + Touchless Thermometer, detailing its features, operation, specifications, and troubleshooting.
Preview FridaBaby Thermonitor Wireless Thermometer User Guide
Comprehensive guide to using the FridaBaby Thermonitor wireless thermometer, including setup, operation, cleaning, and safety information for accurate fever monitoring.
Preview Fridababy 3-in-1 Ear, Forehead + Touchless Thermometer User Manual
User manual for the Fridababy 3-in-1 Ear, Forehead + Touchless Thermometer (Model AOJ-20A), providing instructions for accurate temperature checks in 1 second with color-coded fever indication and multiple measurement modes.