AlorAir Storm PRO & ULTRA Dehumidifier User Manual
Congratulations on purchasing a Storm Pro / Storm Ultra dehumidifier! This manual provides installation and operation instructions.
Identification
Model Name: Storm Pro Storm Ultra
Serial Number: ____________________
Date of Purchase: ____________________
Customer Service
For additional questions concerning the operation of your dehumidifier, please:
- Contact your installing contractor.
- Contact AlorAir Solutions: 1-888-990-7469
- E-mail: sales@alorair.com
Features
- Storm Pro: 85 pints per day at AHAM
- Storm Ultra: 90 pints per day at AHAM
- Only 58 dBA
- Automatic Humidistat
- Built-in Pump with Overflow Protection
- Self Monitoring System
- Eco-Friendly R410A Refrigerant
- Easy Access to Internal Components
- Auto Restart After a Power Outage
- The Unit can be Ducted on the Supply/Outlet, if Necessary
How Your Storm Dehumidifier Works
The Storm Pro / Storm Ultra dehumidifier utilizes its integral humidistat to monitor the conditioned space. When conditions are outside the desired setpoint, the compressor energizes, and air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air, causing water vapor to turn into liquid condensation. The air is then reheated through the condenser coil and distributed back into the room.
Electrical Supply
WARNING: 240 Volts may cause serious injury from electric shock.
Power Supply: 115V, 60 Hz AC Only 1 Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp Time Delay Fuse or Circuit Breaker
- Disconnect electrical power before servicing.
- Only plug unit into grounded electrical outlet.
- Do not use an extension cord.
- Do not use a plug adapter.
Installation
Place the unit in your desired location. The inlet of the machine should be at least 8" from any obstructions. If the unit has been transported in a horizontal position, allow it to sit in an upright position for at least 30 minutes before operating.
WARNING: Do not use dehumidifier in an environment where corrosive or high VOC materials are applied.
Unit Overview
Storm Pro Dehumidifier
Front View
Components: Front Cover, Air Filter, Air Inlet, Handle, Wheel
Rear View
Components: Air Outlet, LCD Display, Tubing & Cord Rack, Drain Tube Connection
Storm Ultra Dehumidifier
Front View
Components: Front Cover, Air Filter, Air Inlet, Handle, Wheel
Rear View
Components: Air Outlet, LCD Display, Tubing & Cord Rack, Drain Tube Connection
LCD Display Instructions
When the machine is powered on but not working:
(After power on, the buzzer makes a sound)
Boot display: The LOGO interface will disappear after 2 seconds. Enter the following interface.
The machine displays when it is not working (Power off state but have electricity).
Main interface display of dehumidification state:
000 JOB HRS: Refers to the working time, defined as the time from starting up to shutting down, including defrost time and standby time. The submenu has a reset function. If not, working time is accumulated. Total time 9999 hours, automatically resets after restart, and displays units in hours (rounded off).
000 LIFE HRS: Refers to the total working time in hours. (Press the mode key + select confirmation key, and total working time will be cleared after 3 seconds.)
IN/OUT 00°F 00% 00 gr/lb: Indicates the temperature, humidity, and moisture content of the air inlet and outlet (gr/lb - grain per pound).
Set 00%: Indicates set humidity.
- If the main interface does not operate for 10 minutes, the screen will go out. Press any key to wake up.
- Other icons light up or flicker when opened.
- The total working time is the accumulation of each working time in hours. (Press the mode key + select confirmation key, and the total working time will be cleared after 3 seconds.)
Dehumidification status submenu interface display
3.1 NAME
Device name displayed on the screen: Alorair Dehumidifier. You can change the device name on the APP application.
3.2 JOB HOURS
Indicates: "Do I need to clear out this time?" Press ">" to clear. When completed, the working time of the main interface and this interface will be reset and start again. After accumulation (9999), clean up and round.
3.3 COIL TEMP
Displays the current temperature of the coil. When it is below zero, the "-" symbol is displayed in front. "-" is not required on zero.
3.4 WIFI HOTSPOT
Factory setting is "OFF". Press ">" to enable wifi hotspot and switch ON/OFF. The device can transmit data and receive APP commands. The icon flickers when connected on the main interface. After successful connection, the icon displays normally.
3.5.1 POWER DOWN TIME
The power down time is adjusted according to ">" and increases from 3 to 20 minutes (3-5-10-15-20), which is the stop time of the fan after shutdown, to better drain water. Factory set for 3 minutes. (The other state of the fan is still 15 seconds.)
3.5.2 POWERING DOWN
The screen displays when you press shut down. Indicates: the fan is closed after a few minutes, and the standby page UNIT OFF is displayed after the fan is closed.
3.6 TEMP UNITS
Used for temperature scale switching. Press the ">>" button to switch °F / °C. The symbol of corresponding parts also changes.
3.7 MOISTURE CONTENT UNITS
Used to switch the unit of GPP value with moisture content. Press ">>" to switch LB or Kg. The symbol of corresponding parts also changes.
3.8 HUMIDISTAT SETPOINT
Used for setting dehumidification mode humidity. Press ">>" to set humidity. The adjustment range is between 25% and 80%. Each key rises or falls 5%, which can be recycled. "CO" indicates continuous mode.
When the setting is completed, do not operate for 5 seconds and begin to take effect. (Otherwise, the compressor will be shut down immediately if below ambient humidity at the time of setting.) Humidity below 25% is recyclable in "CO" mode. The main interface displays the set parameters.
Main interface frosting status display
The machine will display this after defrost when running.
When the machine is running normally, "Defrost SHUTDOWN IN 06:00" will occur in the interface after defrosting. It's defrost countdown in seconds. This screen displays only 3 seconds. Displays the previous interface and status after restoration. If it is the home screen, the frost icon will flash.
When the user is operating in the submenu, the machine is in the frosting state. At this point, the frosting interface displays 3 seconds, and returns to the submenu program in the background countdown. When the user returns to the main interface without any operation, the frosting state is displayed in the main interface by icon flicker.
Compressor on waiting interface display
Compressor protection time not shown:
"Compressor ready IN 03:00" indicates: This interface will be displayed when the compressor is in a protected state. Displays the countdown in seconds. If the situation does not occur within 3 minutes, it is not shown.
Water Pump working interface display
Compressor protection time not shown:
"Pump working countdown": Indicates: No matter in which working state and interface, as long as the pump works, this interface appears and counts down to 28 seconds. However, the interface only displays the previous working status and interface after 3 seconds. For example, after 3 seconds, there is a drainage icon on the main interface and it will flash until the drainage is finished.
Interface display in case of failure
Machine running time fault display:
Make fault judgment and take corresponding actions after starting up. Regardless of the state, the fault is executed first and the fault code is displayed on the interface. If there is a fault in the sub-menu operation, immediately return to this interface to display the fault. Multiple faults can be displayed at the same time.
Description of fault display:
- Humidity sensor fault: When the humidity sensor unit fault or signal cannot be transmitted, the fault is judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button can operate.
- Ambient temperature T≤2: When the sensor continuously detects the ambient temperature of inlet air T=2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values, corresponding to the temperature region operation (recoverable). At this time, the interface cannot be operated. The pump button can be operated.
- Ambient temperature T≥45: When the sensor continuously detects the inlet air environment temperature T=45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped. Other values, corresponding to the temperature region operation (recoverable). At this time, the interface cannot be operated. The pump button can be operated.
- When the compressor is started, if the coil temperature value detected is greater than or equal to (ambient temperature -3 degrees) for 30 minutes continuously, it is judged to be fluorine deficient (except defrosting), E5 is displayed, and the machine cannot be stopped for operation (It needs to be powered up again after troubleshooting). After the power is back on, the machine runs continuously for another 30 minutes for judgment. (The temperature probe is broken, the temperature needs to be minimal). The pump button can be operated.
- After the pump works for 28 seconds when the high water level is switched on, E4 fault is judged when the high water level switch is switched on for 3 consecutive seconds, and E4 fault is displayed. The machine stops and cannot be operated (The pump needs to be powered up again after troubleshooting). The pump can be operated.
Preparing the Unit for Use
Setup
- Position the machine so there is a minimum of 8" clearance for the back and sides, or directly to a specific location for spot dry. If the compressor didn't remain vertical during transportation, wait a minimum of 30 minutes before turning the unit on.
- The included drain line attaches to the unit via a quick connection fitting that is located on the base of the unit. The drain line should be routed to a suitable drain or outside. Since the unit has an integral drain pump, the drain line may go up vertically (no more than 15') prior to reaching the final drain location.
- Firmly insert the power cord into the socket on back of the unit under the air outlet.
- Turn on the dehumidifier and use the control panel to set up the dehumidifier as desired.
Optional Duct Installation
Ducting of the unit allows you to condition an adjacent room or focus the discharge to a specific area. The diameter for the supply/discharge ducting is 6". Flex or layflat ducting can be used for this purpose.
Maintenance and Repair
Cleaning the Machine Body
Use a soft, damp cloth to clean the exterior parts of the unit. Do not use any soap or solvents.
Procedure for filter maintenance
The dust and obstacles on the filter should be removed regularly. You may need to clean and replace the filter.
- Unplug the unit.
- Remove the filter by sliding it upward from the bottom by hand to remove it.
- Check for dirt and build-up.
- For MERV-8 or Pre-filter, wash it in warm water or vacuum it. Do not use soap or cleaners. Also, shake it gently and ensure the filters are dry before reinserting it.
Accessing Internal Components
WARNING: Always unplug unit prior to performing any maintenance.
- Remove the bottom two screws on the front of the machine.
- Remove the upper two screws on the back of the machine.
- Take off the casing/Remove the outer shell of the machine.
Integral Pump Maintenance
NOTE: This pump requires routine maintenance that is not covered by your 1 year parts warranty. Only a defective pump will be repaired or replaced under the warranty.
As with all pumps, preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain system. This includes the drain pan, hose to the condensate pump, pump reservoir, pump head, float assembly, and discharge tubing.
The pump is designed with quick connection construction, making it easy to access the pump and components for service and maintenance.
To Remove Pump from Reservoir:
- Unplug the unit.
- Open the back housing as shown on page 12.
- Remove the condensate tube from the pump.
- Use the quick connect fittings to disconnect the main power and float switch electrical cables.
- Use a flathead screw driver to gently pry the pump off the reservoir.
At least once per year, clean your pump system.
Basic Pump Cleaning:
- Press the pump button (PURGE) to drain any water from reservoir.
- Disconnect power to the dehumidifier.
- Mix a 16 oz cleaning solution of one of the following: 1 oz bleach / 15 oz water or 4 oz white vinegar / 12 oz water. Pour the solution into the drain tray at the base of the coils. NOTE: If you get any cleaning solution on the coils, flush with water.
- Allow cleaning solution to soak for 15 minutes.
- Reconnect power to dehumidifier.
- Pour clean water into reservoir so the pump activates twice (about 16-32 oz. water).
- Repeat if needed or refer to Advanced instructions.
Advanced Pump Cleaning:
- a. Use the manual pump button (PURGE), to drain any water from reservoir.
- b. Unplug the unit, and remove pump from reservoir (see page 13).
- c. Use a wet dry vac or paper towels to remove any remaining water from the pump reservoir.
- Fill the pump reservoir with cleaning solution (15 oz water / 1 oz bleach or 12 oz water / 4 oz white vinegar).
- Reassemble the pump and use the manual pump button to flush the mixture through the discharge tubing.
- Mix another batch of cleaning solution then pour it slowly into drain pan under evaporator coil and allow it to clean the hose from pan to pump. This process can be stopped when the pump energizes 1 time. NOTE: If you get any bleach/water mixture on coils, flush with water.
- Pour sufficient clean water through the drain pan so that the pump activates twice (16-32 ounces).
- Reassemble the unit and return it to operational status.
Cleaning the Coils
The coils on your dehumidifier also need to be cleaned once per year. To clean, simply spray with a self-rinsing, foaming coil cleaner (such as WEB Coil Cleaner).
Storing Your Dehumidifier
If you plan on storing your dehumidifier for an extended period of time:
- Turn unit off and allow to dry.
- Manually drain pump reservoir.
- Wrap and secure the power cord.
- Clean the filter.
- Store in clean, dry environment.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Display is Blank | Poor Connection | Verify that both ends of the Power cord are plugged in. |
Power Outage | Reset power. | |
No Airflow | Filter is Dirty | Clean the filter. |
Air Inlet or Outlet is Blocked | Clear the blockage. | |
Error Code: E1 | Humidity Sensor or Communication Error | Check to ensure that the sensor wire is connected at both ends. If no issues are visible, the sensor may be faulty. |
Error Code: E4 | Problem with Pump | Verify that the pump is properly installed and functioning. If so, unplug the unit for two minutes, then restart. |
Error Code: LO | Room Temperature is below 33.8°F | Increase the room temperature so it is within operating range (above 33.8°F). If error still displays, check sensor. |
Error Code: HI | Room Temperature is above 105°F | Decrease the room temperature so it is within operating range (below 105°F). If error still displays, check the sensor. |
E5 Error Code | Refrigerant Leak | Contact Your Installer for Assistance. |
Pump Alarm-Error Code E4
If an E4 code appears on the display:
- Reset the unit by disconnecting the power cord and then reconnecting it. NOTE: The unit will not function until the code has been cleared.
- Manually check to see if pump is operational by pressing the drain button. Verify that the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.
- If you haven't cleaned the system recently, check the discharge line for an obstruction, then clean the balance of the pump system (see "Maintenance" section for details).
- Replace the hoses and/or pump, if maintenance alone isn't sufficient.
Limited Warranty
This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:
- Six (6) Month parts and labor. This includes the shipments charges for replacement parts or unit.
- One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced.
- Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included.
- Five (5) years parts on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included.
This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Alorair Solutions Inc. will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or support@alorair.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product's finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
File Info : application/pdf, 22 Pages, 5.99MB
DocumentDocumentRelated Documents
![]() |
AlorAir-R App Quick Start Guide Comprehensive guide to setting up and using the AlorAir-R mobile application for controlling AlorAir smart dehumidifiers, including account creation, device connection, and feature navigation. |
![]() |
AlorAir Storm Dehumidifier Installation and Operations Manual This manual provides detailed instructions for the AlorAir Storm SLGR 850X, Storm LGR 850X, and Storm LGR 850 dehumidifiers, covering safety, operation, maintenance, troubleshooting, and warranty information. |
![]() |
AlorAir Storm SLGR 850X/LGR 850X/LGR 850: Installation and Operations Manual Comprehensive installation and operations manual for AlorAir Storm SLGR 850X, Storm LGR 850X, and Storm LGR 850 dehumidifiers, covering safety, operation, maintenance, and troubleshooting. |
![]() |
Alorair Storm LGR Extreme Installation and Operations Manual Comprehensive installation and operations manual for the Alorair Storm LGR Extreme dehumidifier, covering safety, setup, operation, maintenance, troubleshooting, and warranty information. |
![]() |
Alorair Storm SLGR 1600X Dehumidifier: Installation, Operation & Service Manual Comprehensive owner's manual for the Alorair Storm SLGR 1600X dehumidifier, covering installation, operation, maintenance, troubleshooting, and warranty information. |
![]() |
Alorair Storm LGR Extreme Dehumidifier: Installation and Operations Manual Comprehensive guide for the Alorair Storm LGR Extreme dehumidifier, covering installation, operation, maintenance, troubleshooting, error codes, and warranty information. |
![]() |
AlorAir Storm SLGR 1250X Installation and Operations Manual This manual provides comprehensive installation, operation, maintenance, and troubleshooting guidance for the AlorAir Storm SLGR 1250X dehumidifier. It covers safety instructions, electrical supply, unit functionality, parts identification, LCD display usage, and warranty information. |
![]() |
AlorAir Storm SLGR 850X & LGR 850X Dehumidifier Installation and Operations Manual This manual provides installation, operation, maintenance, and troubleshooting guidelines for the AlorAir Storm SLGR 850X and Storm LGR 850X dehumidifiers. It covers safety instructions, electrical supply, unit identification, and warranty information. |