ALORAIR Storm LGR Extreme Installation and Operations Manual

ALORAIR Storm LGR Extreme Installation and Operations Manual

Brand: ALORAIR

Model: Storm LGR Extreme

Contact: Alorair Solutions INC. | Add: 14752 Yorba Ct Chino CA 91710 | Tel: 1-888-990-7469 | E-mail: sales@alorair.com

Certifications: cULus Listed, Intertek

Safety Instructions

  • Do not adjust or alter the unit in any way.
  • The use of unauthorized parts will void your warranty. Contact your approved distributor for assistance.
  • Always unplug the unit prior to removing the cover.
  • Inspect the power cord prior to use and do not use if it is damaged.
  • The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet.

Identification

Prior to installation, record the serial number and date of purchase. The data label on the side of your unit has this information.

Model Number: Storm LGR Extreme

Serial Number: _________________________

Date of Purchase: _________________________

For additional questions concerning your dehumidifier:

  • Contact your installing contractor
  • Contact Alorair Solutions: sales@alorair.com, 888-990-7469

Electrical Supply

Power Supply: 115V, 60 Hz AC, Single Phase

Outlet Requirement: 3-Prong, GFCI

Circuit Protector: 15 Amp

WARNING: Using a 240V outlet may cause serious injury from electric shock.

To reduce risk of injury:

  1. Always disconnect machine from electrical power before servicing.
  2. Only plug unit into a grounded electrical circuit.
  3. Do not use an extension cord.
  4. Do not use a plug adapter.

How the Storm Extreme Works

The Storm LGR Extreme dehumidifier utilizes its integral humidistat to monitor the conditioned space. Once conditions are outside the desired setpoint, the compressor energizes and air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air, so the water vapor turns into liquid condensation. The air is then reheated through the condenser coil and distributed back into the room.

Guidelines

Operation Notes

  • Always make sure that the unit is operated, transported, and stored on a stable surface.
  • For maximum efficiency, operate the unit with all windows and doors closed.
  • Do not place the unit anywhere that may block the inlet or outlet airflow.

Drain Hose Notes

  • Storm LGR Extreme is equipped with an external drain line connection, making it easy to plug in.
  • The drain line can be directed outside or into any sink, drain, etc.
  • For more effective draining, uncoil the entire hose before using.
  • Never place the end of the hose higher than 15 feet.
  • Always ensure that the drain hose is not blocked prior to use.

Transportation Notes

  • Always secure the dehumidifier during transportation.
  • If the unit is transported vertically, return it to a normal horizontal position and let sit for 30 minutes prior to use.

Parts Diagram

The dehumidifier has the following components:

  • Handle
  • Air outlet
  • Air inlet
  • Air Filter
  • Temp/RH sensor
  • Control Panel
  • Condensate Drain Line Quick Connect
  • Power Cable

(Diagrams illustrating the unit's exterior and connection points are provided in the original document.)

Control Panel Guide

The control panel features several buttons for operating the dehumidifier:

  • Power Button: Used to turn the dehumidifier on and off. Can also be pressed to return to the main screen from a sub-menu.
  • Set Button: Used to confirm selections and set the humidity level. Pressing it increases the humidity level by 5% (range 35%-90%), with a default of 50%.
  • Manual Drain Button: Press to remove water from the integral pump reservoir, typically before moving or storing the machine.
  • Menu Button: Cycles through different display interfaces and nine sub-menus (Job Hours, Life Hours, Inlet/Outlet Temperatures, Humidistat Mode, Humidity Setpoint, Temperature Measurement, Language, Coil Temperature, Compressor Current).

Using the Display - Main Screen

1. Power On and Off

To power on the machine, press the power button once. The display will show:

UNIT ON 00 HRS

To power off the machine, press the power button while on the main display screen. The display will show:

UNIT OFF

2. Setting Up the Unit

Once the machine powers on, the display shows:

UNIT ON | 00.0 HRS | INLET 00°C 00%
  • UNIT ON: Indicates the unit is powered on.
  • 00.0 HRS: Describes the time the machine has been running since power on. This includes defrosting time but not standby time. It can be reset and accumulates up to 99.9 hours before resetting to zero.
  • INLET 00°C 00%: Displays the temperature and humidity of the inlet air. Temperature measurement (°F/°C) can be switched in a sub-menu.
  • When in a sub-menu, press the power key to return to the main menu.

3. Defrosting Screen

When the unit enters defrosting mode, it shows "Defrost 000", indicating a countdown until defrosting is finished. After completion, it returns to the main interface. If you are in a sub-menu, the countdown will not be visible until you return to the main interface.

Display during defrosting: UNIT ON | DEFROST 00HRS | 000

If you power off the machine while it is defrosting, the screen will show "Wait for Defrost", indicating the unit will power off after defrost is completed.

Display when waiting for defrost: WAIT FOR DEFROST 000

4. Compressor

This screen indicates the time until the compressor starts running.

Display: PLEASE WAIT | COMP DELAY 000

5. Pump

This screen shows the remaining time before the pump has completed working. The countdown starts at 14 seconds.

Display: PUMP PURGING 00

Using the Display Sub-Menus

1. Job Hours

This screen allows you to clear the job hours. Select ">" to clear the hours. This action clears hours on the main screen, and "RESET" will no longer display on the sub-menu. "RESET" reappears after hours accumulate again.

Display example: JOB HOURS | RESET?>

2. Life Hours

"Life Hours" describes the total working time of the dehumidifier. These hours cannot be cleared.

Display example: LIFE HOURS | 00000 0HRS

3. Inlet/Outlet Temperatures

"INLET 00.00%" describes the temperature of the air inlet.

"OUTLET 00°00%" describes the temperature of the air outlet.

Display example: INLET 00° 00% | OUTLET 00° 00%

4. Humidistat Mode

"Humidistat set point 00%": Used to set the humidity in dehumidification mode. Press the ">" button to set humidity. The range is 25%-80% and CO %. Each press increases humidity by 5%. Settings take effect if not changed within 5 seconds.

Display example: HUMIDISTAT SETPOINT 25%

To switch to continuous operation mode, press the ">" button to lower humidity below 25%. The display will show CO %, indicating continuous mode.

Display example: HUMIDISTAT SETPOINT CO%

In continuous mode, the dehumidifier runs regardless of ambient humidity. To end continuous operation, switch off the device or switch back to the humidity display (25%-80%) using the ">" button.

5. Temperature Measurement

This screen switches temperature measurement between °C and °F. Press the ">" button to switch.

Display example: TEMP UNITS C>

6. Language

Choose your preferred language. Press the (>) button to switch between German, Spanish, and English.

Display example: LANGUAGE ENGLISH

7. Coil Temperature

This screen shows the current temperature of the coils. If the temperature is below zero, it will show "-".

Display example: COIL TEMP -0 0° C

Maintenance Instructions

Before Use

  • Check the power cord for signs of damage (e.g., fraying). Replace if damaged.
  • Check the filter for dirt or obstructions. Clean or replace as necessary.
  • Check the coils for signs of buildup. Clean if needed.

Cleaning the Machine Body

Use a soft, damp cloth to clean the exterior. Do not use soap or solvents.

Filter Maintenance

  1. Unplug the unit.
  2. Slide out the filter.
  3. Check the filter for dirt and buildup.
  4. For MERV-8 filters: Replace as necessary. Checking filters at least 1x/year is recommended.

Removing the Housing

  1. Remove the screws on the housing.
  2. Remove the screws on the air inlet grill and air outlet grill.

Coil Maintenance

  • Once per year, clean the coils with an approved coil cleaner.
  • Use a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.

Pump Maintenance

Pump Access:

Remove the screws on the housing, lift off the pump. Unplug the pump drain line, then remove the screws holding the pump in place.

Cleaning the Pump Reservoir:

Once screws are removed, lift off the pump top and set aside. Use a paper towel to wipe the base of the pump.

Error Codes

If there is an issue with the dehumidifier, one of the following error codes may appear:

Display Error Code Description
E1 E1 Error Humidity sensor has an error. Unit will not operate, but manual pump button can still be used.
LO LO Error Temperature sensor detects incoming air below operating range (33°F). Unit will not operate, but manual pump button can be used. If actual temperature is much higher than 33°F, replace the sensor.
HI HI Error Temperature sensor detects incoming air above operating range (105°F). Unit will not operate, but manual pump button can be used. If actual temperature is much lower than 105°F, replace the sensor.
E5 E5 Error Code Indicates a refrigerant leak. Unit runs for 30 minutes to verify, then powers off.
E4 E4 Error Code Indicates an issue with the pump. Appears when a high water level for the pump is detected.

Troubleshooting

Symptom Cause Solution
Display is Blank Poor Connection Verify that both ends of the power cord are plugged in.
Power Outage Reset power.
No Airflow Filter is Dirty Clean the filter.
Air Inlet or Outlet is Blocked Clear the blockage.
Error Code: E1 Humidity Sensor or Communication Error Check that the sensor wire is connected at both ends. If no issues are visible, the sensor may be faulty.
Error Code: E4 Problem with Pump Verify that the pump is properly installed and functioning. If so, unplug the unit for two minutes, then restart.
Error Code: LO Room Temperature is below 33°F Increase the room temperature to be within the operating range (above 33°F). If the error persists, check the sensor.
Error Code: HI Room Temperature is above 105°F Decrease the room temperature to be within the operating range (below 105°F). If the error persists, check the sensor.
E5 Error Code Refrigerant Leak Contact Your Installer for Assistance.

Dehumidifier Storage

If the unit will be stored for an extended period, follow these steps:

  1. Turn off the unit and allow it to dry.
  2. Clean out the pump reservoir.
  3. Wrap and secure the power cord.
  4. Cover the filter mesh.
  5. Store in a clean, dry space.

Limited Warranty

This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:

  • Six (6) Month parts and labor: Includes shipment charges for replacement parts or unit.
  • One (1) year parts and labor: Does not include shipment charge to send defective product back for repair or replacement.
  • Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator): Transportation cost not included.
  • Five (5) years parts on Refrigeration System ONLY (Compressor, Condenser, and evaporator): Transportation cost not included.

This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions in this user guide or furnished with the product. Alorair Solutions Inc. will not provide in-home service during or after the warranty period. The purchaser may be responsible for shipping charges to bring the product to the manufacturer for service.

To receive warranty service, contact ALORAIR at 888-990-7469 or support@alorair.com. A proof of purchase or order number is required. During the applicable warranty period, a product will be repaired or replaced at ALORAIR's sole option.

IMPORTANT NOTICE: Keep the item's packaging in case warranty service is required.

Limited Warranty Exclusions

This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use and shall not cover the following:

  • Damage occurs in uses for which this product was not intended.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product's finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in a SPA or a room with an OUTDOOR POOL invalidates or voids the limited warranty.

Models: RF-DGA85PBC09, RF-DGA85PBC09 Storm LGR Extreme, Storm LGR Extreme, LGR Extreme, Extreme

PDF preview unavailable. Download the PDF instead.

C1L6jWxkEjL Corel PDF Engine Version 21.2.0.706 CorelDRAW 2019

Related Documents

Preview AlorAir Storm Dehumidifier Installation and Operations Manual
This manual provides detailed instructions for the AlorAir Storm SLGR 850X, Storm LGR 850X, and Storm LGR 850 dehumidifiers, covering safety, operation, maintenance, troubleshooting, and warranty information.
Preview Alorair Storm LGR Extreme Dehumidifier: Installation and Operations Manual
Comprehensive guide for the Alorair Storm LGR Extreme dehumidifier, covering installation, operation, maintenance, troubleshooting, error codes, and warranty information.
Preview ALORAIR Storm LGR Extreme Installation and Operations Manual
Comprehensive guide for the ALORAIR Storm LGR Extreme dehumidifier, covering installation, operation, safety instructions, maintenance, troubleshooting, and warranty information.
Preview AlorAir Storm LGR Extreme Dehumidifier: Professional Restoration & Industrial Drying
Discover the AlorAir Storm LGR Extreme, a high-capacity, professional-grade dehumidifier designed for demanding restoration, industrial, and commercial applications. Features APP control, robust construction, and efficient moisture removal for flood recovery, water damage restoration, and more.
Preview Alorair Storm LGR Extreme Dehumidifier: Installation and Operations Manual
Comprehensive installation and operations manual for the Alorair Storm LGR Extreme dehumidifier, covering safety, setup, maintenance, troubleshooting, and warranty information.
Preview AlorAir-R App Quick Start Guide
Comprehensive guide to setting up and using the AlorAir-R mobile application for controlling AlorAir smart dehumidifiers, including account creation, device connection, and feature navigation.
Preview Alorair Storm LGR Extreme Dehumidifier: Installation and Operations Manual
Comprehensive installation and operations manual for the Alorair Storm LGR Extreme dehumidifier. Covers safety, setup, operation, maintenance, troubleshooting, and warranty information.
Preview AlorAir Storm SLGR 850X & LGR 850X Dehumidifier Installation and Operations Manual
This manual provides installation, operation, maintenance, and troubleshooting guidelines for the AlorAir Storm SLGR 850X and Storm LGR 850X dehumidifiers. It covers safety instructions, electrical supply, unit identification, and warranty information.