AlorAir Storm SLGR 850X, Storm LGR 850X, Storm LGR 850 Installation and Operations Manual
Restoration & Moisture & Ventilation
Brand: AlorAir
Manufacturer: AlorAir Solutions INC.
Address: 14752 Yorba Ct Chino CA 91710 US
Tel: 888-990-7469
Email: sales@alorair.com
Safety Instructions
- Do not adjust or alter the unit in any way.
- The use of unauthorized parts will void your warranty. Contact your approved distributor for assistance.
- Always unplug the unit prior to removing the cover.
- Inspect the power cord prior to use and do not use if it is damaged.
- The unit should only be used with a 115V/60Hz circuit protected by a GFCI outlet.
Identification
Prior to installation of the unit, write down the serial number and date of purchase. You will need this information if you need assistance in the future. The data label on the side of your unit has the necessary information.
Model Number: Storm SLGR 850X, Storm LGR 850X, Storm LGR 850
Serial Number: [Input field for serial number]
Date of Purchase: [Input field for date of purchase]
For additional questions concerning your dehumidifier:
- Contact your installing contractor.
- Contact AlorAir Solutions: sales@alorair.com, 888-990-7469
Electrical Supply
Power Supply: 115V/60Hz
Outlet Requirement: 3-Prong, GFCI
Circuit protector: 15 Amp
WARNING: Using a 220V outlet may cause serious injury from electric shock.
To reduce risk of injury:
- Always disconnect machine from electrical power before servicing.
- Only plug unit into a grounded electrical circuit.
- Do not use an extension cord.
- Do not use a plug adapter.
How the Dehumidifier Works
The dehumidifier utilizes its integral humidistat to monitor the conditioned space. Once conditions are outside the desired setpoint, the compressor energizes and air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air so the water vapor turns into liquid condensation. The air is then reheated through the condenser coil and distributed back into the room.
Guidelines
Operation Notes
- Always make sure that the unit is operated, transported, and stored on a stable surface.
- For maximum efficiency, operate the unit with all windows and doors closed.
- Do not place the unit anywhere that may block the inlet or outlet airflow.
Drain Hose Notes
- The Dehumidifier is equipped with an external drain line connection, making it easy to plug in.
- The drain line can be directed outside or into any sink, drain, etc.
- For more effective draining, uncoil the entire hose before using.
- Never place the end of the hose higher than 15 feet.
- Always ensure that the drain hose is not blocked prior to use.
Transportation Notes
- Always secure the dehumidifier during transportation.
- If the unit is transported vertically, return it to a normal horizontal position, and let sit for 30 minutes prior to use.
Parts Diagram
The dehumidifier has the following components:
- Handle
- Easy Cord and Hose Storage
- Wheel
- Temp/RH Sensor
- Air Outlet
- Control Panel
- Air Inlet
- Air Filter
- Condensate Drain Line Quick Connect
LCD Display Instructions
1. When the machine is powered on but not working:
After power on, a buzzer makes a sound. The boot display shows the AlorAir LOGO interface, which disappears after 2 seconds. The machine then displays a "UNIT OFF" screen, indicating it is not working but has power.
2. Main interface display of dehumidification state:
When the machine is working, the display shows:
- 000 JOB HRS: Refers to the working time, defined as the time from starting up to shutting down, including defrost and standby time. Total time is 9999 hours, resetting automatically after restart.
- 000 LIFE HRS: Refers to the total working time in hours.
- IN/OUT: Displays the temperature (°F) and moisture content (gr/lb) of the air inlet and outlet.
- Set: Displays the set humidity percentage.
If the main interface does not operate for 10 minutes, the screen will go blank. Press any key to wake up.
Other icons may light up or flicker when opened.
3. Dehumidification status submenu interface display:
3.1 Device Name
The device name displayed on the screen can be changed on the APP application.
3.2 Job Hours
Displays the working time of the main interface and the working time of the main interface and the working time of the main interface. Press ">" to reset. Hold to reset.
3.3 Coil Temp
Displays the current temperature of the coil. If it is below zero, the "-" symbol is displayed. If it is below zero, the symbol is displayed in front. "*" is not required on zero.
3.4 WiFi Hotspot
Factory setting is "OFF". Press ">" to enable the Wi-Fi hotspot and switch ON/OFF. The device can transmit data and receive APP commands. The icon flickers when connected on the main interface. After successful connection, the icon displays normally.
3.5.1 Power Down Time
The power down time is adjusted according to ">". The power down time increases from 3 to 20 minutes (3-5-10-15-20). This is the stop time of the fan after shutdown, to better drain the water. Factory set for 3 minutes. (The other state of the fan is still 15 seconds.)
3.5.2 Powering Down
The screen displays when you press shut down. The fan closes after a few minutes, and the standby page "UNIT OFF" is displayed after the fan is closed.
3.6 Temp Units
Used for temperature scale switching. Press the ">" button to switch between °F / °C. The corresponding symbol changes.
3.7 Moisture Content Units
Used to switch the unit of GPP value with moisture content. Press ">" to switch between LB or KG. The corresponding symbol changes.
3.8 Humidistat Setpoint
Used for setting dehumidification mode humidity. Press ">" to set the humidity. The adjustment range is between 25% and 80%. Each key rises or falls 5%, which can be recycled. "CO" indicates continuous mode.
When the setting is completed, do not operate for 5 seconds to take effect. If the humidity is below 25%, "CO" mode is recyclable. The main interface displays the set parameters.
4. Main interface frosting status display:
The machine displays this after defrost when running. When the machine is running normally, "DEFROST SHUTDOWN IN 06:00" will appear in the interface after defrosting. It's a defrost countdown in seconds. This screen displays only 3 seconds. Displays the previous interface and status after restoration. If it is the home screen, the frost icon will flash.
When the user is operating in the submenu, the machine is in the frosting state. At this point, the frosting interface displays for 3 seconds and returns to the submenu program in the background countdown. When the user returns to the main interface without any operation, the frosting state is displayed in the main interface by the frost icon flashing.
5. Compressor on waiting interface display
Compressor protection time not shown: "Compressor ready IN 03:00" indicates that the interface will be displayed when the compressor is in a protected state (including power-on and shutdown, humidity rises immediately after the arrival of LO/HI, and shutdown resumes immediately after the emergence of LO/HI). Displays the countdown in seconds. If the above situation does not occur within 3 minutes, it is not shown.
6. Water Pump working interface display
Compressor protection time not shown: "Pump working countdown" indicates that no matter in which working state and interface, as long as the pump works, this interface appears and counts down to 28 seconds. However, the interface only displays the previous working status and interface after 3 seconds. For example, after 3 seconds, there is a drainage icon on the main interface and it will flash until the drainage is finished.
7. Interface display in case of failure
Machine running time fault display: Fault codes like E1, E4, LO, HI, E5 are displayed. Make fault judgment and take corresponding actions after starting up. Regardless of the state, the fault is executed first and the fault code is displayed on the interface. If there is a fault in the sub-menu operation, it immediately returns to this interface display fault (including defrosting state). The fault is judged when the pump works, and the fault is displayed as usual, but the pump needs to complete the water pumping this time. Multiple faults can be displayed at the same time.
Description of fault display:
- Humidity sensor fault (E1): When the humidity sensor unit fault or signal cannot be transmitted, the fault is judged to be E1. The machine is out of operation (power on again after troubleshooting). Pump button can operate.
- Ambient temperature T≤2 (LO): When the sensor continuously detects the ambient temperature of inlet air T≤2 degrees for 600 seconds, the fault is judged to be LO and the whole machine is stopped. Other values, corresponding to the temperature region operation (recoverable). At this time, the interface cannot be operated. The pump button can be operated.
- Ambient temperature T≥45 (HI): When the sensor continuously detects the inlet air environment temperature T≥45 degrees for 15 seconds, the fault is judged to be HI and the whole machine is stopped. Other values, corresponding to the temperature region operation (recoverable). At this time, the interface cannot be operated. The pump button can be operated.
- E5 Error Code: Refrigerant Leak. Contact Your Installer for Assistance.
Maintenance Instructions
Before Use
- Check the power cord for signs of damage such as fraying. Replace the cord before use if there is any damage.
- Check the filter for signs of dirt or obstructions. Clean or replace the filter as necessary.
- Check the coils for signs of buildup. Clean if needed.
Cleaning the Machine Body
Use a soft, damp cloth to clean the exterior of the unit. Do not use any soap or solvents.
Filter Maintenance
- Unplug the unit.
- Slide out the filter.
- Check the filter for dirt and buildup.
- For a Pre-Filter or MERV-8: Clean the filter mesh by vacuuming it or washing with warm water (no soap or cleaners). Gently shake the filter dry, then reinsert it.
- For a Carbon, or HEPA Filter: If there is dirt or buildup, replace the filter.
Removing the Housing
- Remove the screws on the housing.
- Remove the screws on the air inlet grill and air outlet grill.
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner.
- Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.
Pump Maintenance
Pump Access:
Remove the screws on the housing, then lift off. Unplug the pump drain line, then remove the screws holding the pump in place.
Cleaning the Pump Reservoir:
Once the screws are removed, lift off the top of the pump and set aside. Use a paper towel to wipe out the base of the pump.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Display is Blank | Poor Connection | Verify that both ends of the power cord are plugged in. |
No Airflow | Filter is Dirty | Clean the filter. |
Air Inlet or Outlet is Blocked | Clear the blockage. | |
Error Code: E1 | Humidity Sensor or Communication Error | Check to ensure that the sensor wire is connected at both ends. If no issues are visible, the sensor may be faulty. |
Error Code: E4 | Problem with Pump | Verify that the pump is properly installed and functioning. If so, unplug the unit for two minutes, then restart. |
Error Code: LO | Room Temperature is below 33.8° F | Increase the room temperature so it is within operating range (above 33.8° F). If error still displays, check sensor. |
Error Code: HI | Room Temperature is above 110° F | Decrease the room temperature so it is within operating range (below 110° F). If error still displays, check the sensor. |
E5 Error Code | Refrigerant Leak | Contact Your Installer for Assistance. |
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Turn off the unit and allow it to dry.
- Clean out the pump reservoir.
- Wrap and secure the power cord.
- Cover filter mesh.
- Store in clean, dry space.
Limited Warranty
This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:
- Six (6) Month parts and labor: Includes shipment charges for replacement parts or unit.
- One (1) year parts and labor: Does not include shipment charge to send the defective product back for repair or replacement.
- Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator): Transportation cost not included.
- Five (5) years parts on Refrigeration System ONLY (Compressor, Condenser, and evaporator): Transportation cost not included.
This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Alorair Solutions Inc. will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or support@alorair.com. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product's finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidates or voids limited warranty.