AprilAire Healthy Air Solutions
Quick Reference | January 2024
Healthy Fresh Air in every home.
About AprilAire
AprilAire provides professional-grade Healthy Air solutions, dedicated to enhancing people's health by improving the air in their homes. Healthy Air is essential for a healthy lifestyle and overall well-being. AprilAire designs and builds innovative solutions inspired by consumer needs and professional contractor expertise.
AprilAire is Healthy Air.
5-year warranty on all installed products
AprilAire offers solutions for: Radon Mitigation [icon], Air Filtration [icon], UVC [icon], Fresh Air Ventilation [icon], Humidification [icon], Dehumidification [icon], Zone Control [icon].
Mitigation Fans
AprilAire Radon Mitigation Fans are specifically designed for radon mitigation, offering superb performance and ultra-quiet operation. They meet all electrical code requirements, feature housing that stays white, and have water-hardened motorized impellers. Seams are sealed to inhibit radon leakage (ARN15F/ARN25F are double snap sealed). They are ETL Listed for indoor or outdoor use, have thermally protected motors, are rated for commercial and residential use, and feature a patent-pending design. The ARNHPF model is optimal for moderate to tight soils and includes technology to inhibit radon and soil gas leakage. All are ETL listed by Intertek to UL507 and CSA C22.2 Standards.
Model Specifications
MODEL | FAN DUCT DIAMETER | RECOMMENDED PRESSURE " WC | WATTS | TYPICAL CFM vs. STATIC PRESSURE |
---|---|---|---|---|
ARN15F | 4" | 1.7 | 41-72 | 166 - 126 82 41 3 - - - - |
ARN25F | 6" | 2.3 | 70-170 | 375 340 282 204 140 70 - - - - |
ARNHPF | 3" | 4.0 | 70-170 | - 110 - 97 88 79 68 54 36 14 |
Dimensions: ARN15F (9.7" W x 8.5" H), ARN25F (11.75" W x 8.6" H), ARNHPF (11.9" W x 10.9" H).
5 YEAR WARRANTY [icon]
Mitigation Kits
Kits include: fan, manometer, couplings, and radon system alarm.
MODEL | SLAB SIZE | DIMENSIONS (DxH) | COLOR | FAN DUCT DIAMETER | PRESSURE |
---|---|---|---|---|---|
ARN15K | <1500 sq. ft. | 9.7 x 8.5 | White | 4" | 1.7 WC |
ARN25K | 1500-2500 sq. ft. | 11.75 x 8.6 | White | 6" | 2.3 WC |
ARNHPK | Moderate to Tight Soil | 11.9 x 10.9 | White | 3" | 4.0 WC |
Radon Accessories
- Manometer (P/N ARN05M): Mounts to the outside of PVC pipe on a radon mitigation system and measures vacuum pressure in real time, helping to indicate potential issues with the fan. It can serve as a secondary indicator that vacuum pressure has changed in the event of a system alarm going off, helping to confirm that it's not a false alarm.
- Transition Fitting (P/N ARNTF4): Consolidates the number of fittings needed in outdoor radon mitigation system installations. Connects a 4" fan pipe to a 4" exhaust pipe with a weir (not included) for capturing and draining condensate. Weir is included in the Condensate Bypass Kit.
- Condensate Bypass Kit (P/N ARNCBK): Designed to drain condensation around the fan in outdoor installs.
- Radon-T Fitting (P/N ARNSIT): Designed for use in adding radon mitigation to new construction and crawl spaces. Provides 4-way airflow, allowing moisture and soil gases to be drawn from all angles.
- System Alarm (P/N ARNALM): Advanced vacuum monitoring device utilizing piezoresistive pressure sensor (PPS) technology. It provides homeowners with an easy-to-read, easy-to-use system alarm that requires no interpretation.
Humidity Control - Humidifiers
Humidifiers are part of the AprilAire Healthy Air System.
Humidifier Types and Specifications
HUMIDIFIERS | TYPE OF HUMIDIFICATION | UNIT SIZE (WIDTH X HEIGHT X DEPTH) | CAPACITY (GPD=GALLONS PER DAY) | ELECTRICAL DATA | WATER PANEL/CANISTER |
---|---|---|---|---|---|
#800* | Steam | 10 1/8" x 20 7/8" x 7 1/8" | 11.5 GPD | 120 VAC 60HZ 11.5A | 80 |
#801*** | (Fan Pack: 14" x 6 29/32" x 3 15/16") (Finished Grille: 16 3/16" x 9" x 1 3/32") |
16.0 GPD | 120 VAC 60HZ 16.0A 208 VAC 60HZ 11.5A 240 VAC 60HZ 11.5A |
||
#865** | 15 29/32" x 18" x 10 11/32" | 20.5 GPD | 208 VAC 60HZ 16.0A 240 VAC 60HZ 16.0A |
||
#866*** | 30.0 GPD, 23.3 GPD, 34.6 GPD | ||||
#700* | Fan Powered Evaporative | 14 3/4" x 14 31/100" (W x H) | 18 GPD | 120 VAC 60HZ 0.8A | |
#700M** | |||||
#600* | Large Bypass Evaporative | 15 3/8" x 15 3/4" x 10 1/4" | 17 GPD | 24 VAC 60HZ 0.5A | 6" dia. round opening |
#600M** | |||||
#500* | Small Bypass Evaporative | 15 5/8" x 13" x 10 1/4" | 12 GPD | 24 VAC 60HZ 0.5A | 6" dia. round opening |
#500M** | |||||
#400* | Water Saver Bypass Evaporative | 15 3/8" x 15 3/4" x 10 1/4"* | 17 GPD | 24 VAC 60HZ 0.5A | 6" dia. round opening |
#400M** | |||||
#300 | Self-Contained Evaporative | 14 3/8" x 12 1/2" x 22 3/32" | 13 GPD | 120 VAC 60HZ 0.7A |
Notes:
* Automatic Digital Control. ** Manual Control. *** Modulating Steam Humidifier - For precise RH control. Controls are sold separately.
Model 400 can be installed in heat pump applications; however, evaporation is approximately 60% of rated capacity due to lower air temperature delivery. Hot water use provides less benefit with Model 400.
Model 800LC available with 80LC canister for less conductive water (75-300 µS/cm) and 120VAC applications.
GPD = Gallons Per Day, as recommended by AHRI.
Evaporative capacities assume blower is active 100% of the time, plenum temperature is at 120°F and water is cold.
Bypass Humidifiers can be installed on the supply or return plenum.
Water Usage Rate: Model 300 is 6 gph; Models 500, 600, 700 are 3 gph; Model 400 is 0.7 gph; Model 800 is 0.6 to 1.8 gph depending on voltage, amp draw and water quality.
Humidifier Sizing Guidelines
GPD needed per square foot based on building structure tightness.
VOLUME OF BUILDING (FT³) | BUILDING FLOOR AREA (FT²) WITH 8 FT CEILINGS | ||||||
---|---|---|---|---|---|---|---|
1000 Ft² | 1500 Ft² | 2000 Ft² | 2500 Ft² | 3000 Ft² | 4000 Ft² | ||
8000 | Tight: 3.3 GPD | 5.0 GPD | 6.7 GPD | 8.3 GPD | 10.0 GPD | 13.4 GPD | |
12000 | Average: 6.7 GPD | 10.0 GPD | 13.4 GPD | 16.7 GPD | 20.0 GPD | 26.7 GPD | |
16000 | Loose: 10.0 GPD | 15.0 GPD | 20.0 GPD | 25.0 GPD | 30.1 GPD | 40.1 GPD | |
20000 | |||||||
24000 | |||||||
32000 | |||||||
40000 | 16.7 GPD | 33.4 GPD | 50.1 GPD |
Regional Humidifier Applications
AprilAire humidifiers can be installed on many different types of HVAC equipment. This application guide assists in selecting the appropriate AprilAire product based upon geography and heating equipment.
Considerations: It is important to consider the plenum temperature, air flow (fan speed) and run time (heat call primary, fan only call secondary) when selecting products. Automatic humidity controls have an integrated blower activation feature, which is factory set to 'ON'. It will turn on the humidifier and the HVAC blower for humidification without a heat call. It will increase the run time and effectiveness of the humidifier. Installations with a manual humidifier control can increase capacity by turning the thermostat fan to "ON". When installing evaporative humidifiers, it is recommended they are plumbed to hot water.
Climate Zone/Recommended AprilAire Humidifier Solution by Model
EQUIPMENT | CLIMATE ZONE/RECOMMENDED APRILAIRE HUMIDIFIER SOLUTION BY MODEL | ||||
---|---|---|---|---|---|
MIDWEST/ NORTHEAST | MID-ATLANTIC/ MID-SOUTHERN | MOUNTAIN | SOUTH | DESERT (SOUTHWEST) | |
Gas/Oil Furnace-Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Gas/Oil Modulating Furnace** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Heat Pump/Geo-Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Heat Pump/Geo-Modulating** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Boiler With AHU (No Heat Source) | 800 | 800 | 800 | 800 | 800 |
Boiler With AHU and Hot Water Coil/ Hydro Air Unit | 700/800 | 700/800 | 800 | 800 | 800 |
Boiler | 300/865 | 300/865 | 300/865 | 300/865 | 300/865 |
Electric Baseboard Heating | 300/865 | 300/865 | 300/865 | 300/865 | 300/865 |
Humidifying with A/C Unit | 800 | 800 | 800 | 800 | 800 |
Notes: *PSC, constant torque ECM **Variable speed ECM. Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used in these applications if the HVAC system pressure differential between supply and return ducts is at least 0.08 in. wg and air temperature, hot water and continuous fan in the supply duct is at least 100°F.
Humidity Control - Dehumidifiers
Dehumidifiers are part of the AprilAire Healthy Air System.
Dehumidifier Specifications
MODEL | UNIT SIZE (WIDTH X HEIGHT X LENGTH) | CAPACITY (PPD = PINTS PER DAY) | AIRFLOW @ VARYING E.S.P. (EXTERNAL STATIC PRESSURE - DRY COIL) | UNIT WEIGHT (LBS.) |
---|---|---|---|---|
#E070 | 12.5" x 12.5" x 25" | 70 ppd @80°F/60%RH 53 ppd @73°F/60%RH |
0.0" w.c.: 170 CFM 0.2" w.c.: 140 CFM |
56 |
#E080 | 14" x 15" x 26" | 80 ppd @80°F/60%RH 65 ppd @73°F/60%RH |
0.0" w.c.: 185 CFM 0.2" w.c.: 135 CFM 0.4" w.c.: 85 CFM |
63 |
#E080H1 | (Hardwired unit) | |||
#E100 | 14" x 15" x 26" | 100 ppd @80°F/60%RH 85 ppd @73°F/60%RH |
0.0" w.c.: 280 CFM 0.2" w.c.: 245 CFM 0.4" w.c.: 210 CFM |
64 |
#E100C2 | (On casters) | |||
#E130 | 19.5" x 18.5" x 30" | 130 ppd @80°F/60%RH 105 ppd @73°F/60%RH |
0.0" w.c.: 310 CFM 0.2" w.c.: 270 CFM 0.4" w.c.: 225 CFM |
98 |
#E130H1 | (Hardwired unit) | |||
#E130C2 | (On casters) |
Note: E100C and E130C are on casters.
Dehumidifier Sizing Guidelines
Recommended home floor area (ft²) for each listed dehumidifier, used as sizing guidelines only. Actual home size depends on location, ventilation rate, occupant habits, AC system moisture removal, and comfort conditions.
MODEL | REGION A (Most Humid) | REGION B | REGION C | |||
---|---|---|---|---|---|---|
LOOSE | TIGHT | LOOSE | TIGHT | LOOSE | TIGHT | |
MODEL E080 | 3,200 Ft² | 4,400 Ft² | 2,600 Ft² | 3,900 Ft² | 1,600 Ft² | 2,300 Ft² |
MODEL E100 | 4,000 Ft² | 5,500 Ft² | 3,200 Ft² | 5,000 Ft² | 2,000 Ft² | 3,000 Ft² |
MODEL E130 | 5,200 Ft² | 7,200 Ft² | 3,900 Ft² | 6,500 Ft² | 2,300 Ft² | 3,600 Ft² |
Provide on-demand sizing recommendations using the Dehumidifier Selection Assistant at AprilAirepartners.com/dsa.
Air Filtration - Air Cleaners
Air Cleaners are part of the AprilAire Healthy Air System.
Air Cleaner Specifications
AIR CLEANERS | NOMINAL SIZE (IN INCHES) | CABINET SIZE (W x H x D) | SHIPPING WEIGHT (LBS) | INCLUDED FILTER | COMPATIBLE FILTERS* |
---|---|---|---|---|---|
#2216 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 20 | MERV 16 | 213CBN, 213, 210 |
#2416 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19.25 | MERV 16 | 413CBN, 413, 410 |
#2516 | 31 x 28 | 6 3/4" x 31" x 30 1/16" | 24.9 | MERV 16 | 513CBN, 513, 510 |
#2210 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 19 | MERV 11 | 213CBN, 213, 210 |
#2310 | 20 x 20 | 6 3/4" x 20 3/8" x 22 1/16" | 17 | MERV 11 | 210 |
#2410 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19 | MERV 11 | 413CBN, 413, 410 |
#1110 | 16 x 20 | 6 3/4" x 17 3/4" x 22 1/16" | 13 | MERV 11 | 110 |
#1210 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 20 | MERV 11 | 210 |
#1310 | 20 x 20 | 6 3/4" x 20 3/8" x 22 1/16" | 15 | MERV 11 | 210 |
#1410 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19 | MERV 11 | 410 |
#1510 | 31 x 28 | 6 3/4" x 31" x 30 1/16" | 28 | MERV 11 | 510 |
#1910 | 25 x 20 | 6 3/4" x 25 1/16" x 22 1/16" | 18 | MERV 11 | 910 |
#1610 | 16 x 25 | 15 11/16" x 17 13/16" x 30 3/16" | 31 | MERV 11 | 410 |
#1620 | 20 x 25 | 15 11/16" x 22 1/8" x 27 3/8" | 32.4 | MERV 11 | 210 |
#5000 (ELECTRONIC AIR CLEANER) | 16 x 25 | W: 12" H (front): 18 3/8" H (back): 17 3/4" D: 31" | 35 | EAC | 501 |
*Included filter is always available as a replacement.
Air Filtration - Air Sanitization (UVC)
UVC is part of the AprilAire Healthy Air System.
UVC Models
MODEL # | CONTAINS | AIR CLEANER SIZE INCLUDED (H X L X W) | FILTER |
---|---|---|---|
AUV24V | UVC Coil Cleaner | ||
AUVRPB | Replacement UVC Lamp | ||
UV12 | 1210 Air Cleaner AUV24V UV-C Coil Cleaner | 20" x 25" x 4" | 210 MERV 11 |
UV14 | 1410 Air Cleaner AUV24V UV-C Coil Cleaner | 16" x 25" x 4" | 410 MERV 11 |
UV22 | 2210 Air Cleaner AUV24V UV-C Coil Cleaner | 20" x 25" x 4" | 213 MERV 13 |
UV24 | 2410 Air Cleaner AUV24V UV-C Coil Cleaner | 16" x 25" x 4" | 413 MERV 13 |
Air Filtration - Air Filters
Air Filters are part of the AprilAire Healthy Air System.
Static Pressures at Variable CFM (in. w.c.)
FILTER NO. | STATIC PRESSURES AT VARIABLE CFM (IN. W.C.)* | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
200 | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | 2600 | 2800 | 3000 | |
216 | 0.06 | 0.09 | 0.13 | 0.17 | 0.23 | 0.29 | 0.36 | ||||||||
416 | 0.07 | 0.10 | 0.13 | 0.18 | 0.24 | 0.31 | |||||||||
516 | 0.04 | 0.05 | 0.07 | 0.09 | 0.10 | 0.13 | 0.15 | 0.18 | 0.21 | 0.24 | 0.27 | 0.31 | |||
113 | 0.03 | 0.07 | 0.11 | 0.16 | 0.22 | 0.29 | |||||||||
213 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | |||||
313 | 0.03 | 0.05 | 0.09 | 0.13 | 0.17 | 0.23 | |||||||||
413 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | |||||
513 | 0.01 | 0.02 | 0.04 | 0.05 | 0.05 | 0.07 | 0.08 | 0.10 | 0.11 | 0.13 | 0.15 | 0.17 | 0.18 | 0.20 | 0.23 |
613 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | |||||
813 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | |||||
913 | - | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.18 | 0.22 | 0.27 | |||||
213CBN | 0.04 | 0.07 | 0.10 | 0.13 | 0.17 | 0.21 | 0.25 | 0.30 | 0.35 | ||||||
413CBN | 0.04 | 0.07 | 0.10 | 0.14 | 0.19 | 0.24 | 0.29 | 0.36 | 0.43 | ||||||
513CBN | 0.03 | 0.04 | 0.05 | 0.07 | 0.08 | 0.10 | 0.12 | 0.15 | 0.17 | 0.20 | 0.22 | 0.25 | 0.29 | 0.32 | |
110 | 0.02 | 0.05 | 0.06 | 0.10 | 0.14 | 0.20 | |||||||||
210 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | |||||
310 | 0.02 | 0.04 | 0.06 | 0.10 | 0.14 | 0.19 | |||||||||
410 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | |||||
510 | 0.02 | 0.02 | 0.03 | 0.04 | 0.04 | 0.05 | 0.06 | 0.07 | 0.09 | 0.10 | 0.12 | 0.14 | 0.15 | 0.17 | 0.19 |
610 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | |||||
810 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | |||||
910 | - | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.18 | 0.22 | 0.27 | |||||
201 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.12 | 0.15 | 0.18 | 0.21 | 0.25 | |||||
401 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 | |||||
501 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 |
*Highest value shown is maximum recommended airflow capacity.
Removal Efficiency (Based on Particle Size)
0.3µ-1.0 MICRONS | 1.0µ-3.0 MICRONS | 3.0µ-10.0 MICRONS | |
---|---|---|---|
MERV 16 | 95% | 98% | 99% |
MERV 13 | 63% | 88% | 93% |
MERV 11 | 37% | 67% | 92% |
MERV 10 | 22% | 56% | 92% |
EAC - 5000 | 89% | 95% | 98% |
Test Method: MERV 10-16 per ASHRAE 52.2.2012, EAC per AHRI 680-2009.
Upgrade Kits
UPGRADE KITS | NOMINAL SIZE (IN INCHES) | COMPATIBLE WITH | INCLUDED FILTER | RAILS | STATIC PRESSURE DROP (IN. W.C.) @ 1200 CFM | MAXIMUM AIRFLOW CAPACITY (IN CFM) |
---|---|---|---|---|---|---|
#1213 | 20 x 25 | AprilAire or Space-Gard 2200 | 213 (MERV 13) | 4893 | 0.15 | 2000 |
#1413 | 16 x 25 | AprilAire or Space-Gard 2400 | 413 (MERV 13) | 4894 | 0.17 | 2000 |
Upgrade Rails
RAILS | Nominal Size (in inches) | Compatible With | Uses Filter Model | Maximum Airflow Capacity (in CFM) |
---|---|---|---|---|
#4893 | 20x25 | AprilAire or Space-Gard 2200 | 210, 213, 213CBN | 2000 |
#4894 | 16x25 | AprilAire or Space-Gard 2400 | 410, 413, 413CBN | 2000 |
#4897 | 16x25 | 16x25 Competitive Cabinets | 610, 613 | 2000 |
#4898 | 20x25 | 20x25 Competitive Cabinets | 810, 813 | 2000 |
#4899 | 16x20 | 16x20 Competitive Cabinets | 110, 113 | 1200 |
#4900 | 20x20 | 20x20 Competitive Cabinets | 310, 313 | 1200 |
Replacement Filters
FILTER NO. | USED WITH APRILAIRE AIR CLEANER MODELS | NOMINAL SIZE (IN INCHES) | STATIC PRESSURE DROP (IN. W.C.) @ 1200 CFM | MAXIMUM AIRFLOW CAPACITY (IN CFM) |
---|---|---|---|---|
201 | AprilAire or Space-Gard 2200** | 20 x 25 | 0.12 | 2000 |
401 | AprilAire or Space-Gard 2400** | 16 x 25 | 0.14 | 2000 |
**Air Cleaner models no longer available.
Healthy Air Controls - Thermostats
Thermostats are part of the AprilAire Healthy Air System.
Residential Thermostat Models
RESIDENTIAL MODEL NUMBER | STAGES | Dimensions (W x H x D) | FEATURES |
---|---|---|---|
S84N1H1C | 1H/1C | 3.75" x 3.75" x 1.00" | Easy to Read Display, Simple Setup, Temperature Control |
S84NSU | 1H/1C, 2H/1C | Temperature Control | |
S86NMU | 2H/2C, 4H/2C HP | Temperature Control, Humidifier Control, Controls Whole-Home Dehumidifier | |
S86NMUPR | 2H/2C, 4H/2C HP | Temperature Control, Humidifier Control, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification | |
S86WMUPR ** | 3H/3C, 4H/2C HP | 4.38" x 4.38" x 0.8" | Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Simple Setup, Temperature Control, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Air Cleaning, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Humidifier Control, Energizes HVAC Blower for Humidity, Controls Humidifier with 24 VAC Dry Contact, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification, Senses and Displays Indoor RH, Dehumidifier "Dehumidifier On" Notice, Control, Energizes HVAC Blower for Dehumidification, Controls Dehumidifier with 24 VAC Dry Contact, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Ventilation Control, Configurable Temperature and Humidity Limits, "Ventilation On" Notice, Controls Air Cleaner and Humid or Dehumid or Vent |
8910 | 3H/3C, 4H/2C HP | 6" x 4.85" x 1.25" | Programmable and Non-Programmable, Temperature Control, Humidifier Control, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification, Senses and Displays Indoor RH, Controls Dehumidifier with 24 VAC Dry Contact, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Ventilation Control, Configurable Temperature and Humidity Limits, Controls Air Cleaner and Humid, Dehumid and Vent |
8910W** | 3H/3C, 4H/2C HP | Wi-Fi, compatible | |
8920W** | 3H/3C, 4H/2C HP | 7.1" x 4.85" x 1" | Wi-Fi, Programmable and Non-Programmable, Temperature Control, Humidifier Control, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification, Senses and Displays Indoor RH, Controls Dehumidifier with 24 VAC Dry Contact, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Ventilation Control, Configurable Temperature and Humidity Limits, Controls Air Cleaner and Humid, Dehumid and Vent |
8840 (IAQ Control Equipment Module) | 8 3/5" x 9 3/5" x 1 9/10" | Controls Air Cleaner and Humid, Dehumid and Vent |
**Wi-Fi, compatible and compatible. Wireless Sensors for Model S86WMUPR only.
Thermostat Features: Easy to Read Display, Simple Setup, Temperature Control, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Air Cleaning, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Humidifier Control, Energizes HVAC Blower for Humidity, Controls Humidifier with 24 VAC Dry Contact, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification, Senses and Displays Indoor RH, Dehumidifier "Dehumidifier On" Notice, Control, Energizes HVAC Blower for Dehumidification, Controls Dehumidifier with 24 VAC Dry Contact, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Ventilation Control, Configurable Temperature and Humidity Limits, "Ventilation On" Notice, Controls Air Cleaner and Humid or Dehumid or Vent, Controls Air Cleaner and Humid, Dehumid and Vent.
Product Configuration: Wired Outdoor Temperature Sensor Included. Two-Part Design—Only 3 Wires to the Living Space.
Wireless Sensors
MODEL | TYPE OF SENSOR | COMMUNICATIONS | WIRELESS RANGE | TEMPERATURE MEASUREMENT RANGE/ ACCURACY | HUMIDITY MEASUREMENT RANGE/ ACCURACY | BATTERY LIFE | BATTERY TYPE |
---|---|---|---|---|---|---|---|
#Z10IDT | Indoor Wireless Temperature and Humidity Sensor | 2.4 GHz | 35+ feet in typical application* | Range: -40°F to 125°F Accuracy: ±2°F (40°F to 105°F), ±5°F outside of this range |
Range: 0.5% to 99.5% RH Accuracy: ±5% RH between 20% and 80% RH |
1 year | Lithium CR2032 type |
#Z10ODT | Outdoor Wireless Temperature and Humidity Sensor | 2.4 GHz | 35+ feet in typical application* | Range: -40°F to 125°F Accuracy: ±2°F (40°F to 105°F), ±5°F outside of this range |
Range: 0.5% to 99.5% RH Accuracy: ±5% RH between 20% and 80% RH |
2 years | Lithium CR2477 type |
*Actual distance varies dependent on number and type of interferences. Refer to signal strength for best results.
Wireless Sensor Features: Get precise temperature control, reducing hot/cold spots, by averaging an installed thermostat with wireless indoor sensors. Temperature/event scheduling for specific areas of the house possible with wireless sensor installation (indoor sensor only).
Zone Control Panels
MODEL | SPECIFICATIONS | Overall Dimensions (W x H x D) | Humidity | Operating Temperature | Shipping Temperature | Voltage | Maximum Current |
---|---|---|---|---|---|---|---|
6404 (Universal Multistage) | 4 Zone (expandable to 12 zones with Model 6401) 2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump) Compatible with Model 8056 wireless outdoor sensor |
8 63/100" W x 14 18/25" H x 1 43/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F Zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
6403 (Universal Multistage) | 3 Zone Universal Multistage | ||||||
6303 (Heat Pump Only) | 3 Zone Heat Pump 2 Heat 1 Cool Single Stage |
8 63/100" W x 9 33/50" H x 1 43/50" D | 5% - 90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F Zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
6302 (Heat Pump Only) | 2 Zone Heat Pump | ||||||
6203 (Conventional Only) | 3 Zone Heat/Cool 1 Heat 1 Cool Single Stage |
8 63/100" W x 9 33/50" H x 1 43/50" D | 5%–90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F Zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
6202 (Conventional Only) | 2 Zone Heat/Cool |
** Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24VAC 40VA universal transformer.
Zone Dampers
Rectangular Damper Size & Stock No.
Side Mount (Motor mounted on short dimension) / W3 indicates power open/ power closed
NOMINAL WIDTH (IN INCHES) | STOCK NO. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
8" | 10" | 12" | 14" | 16" | 18" | 20" | 22" | 24" | 26" | 28" | 30" | |
8" (203MM) | 6721 6721W3 |
6722 6722W3 |
6723 6723W3 |
6724 6724W3 |
6725 6725W3 |
6726 6726W3 |
6727 6727W3 |
6728 6728W3 |
6729 6729W3 |
6730 6730W3 |
6731 6731W3 |
6753 6753W3 |
10" (254MM) | 6732 6732W3 |
6733 6733W3 |
6734 6734W3 |
6735 6735W3 |
6736 6736W3 |
6737 6737W3 |
6738 6738W3 |
6739 6739W3 |
6740 6740W3 |
6741 6741W3 |
6742 6742W3 |
|
12" (305MM) | 6743 6743W3 |
6744 6744W3 |
6745 6745W3 |
6746 6746W3 |
6747 6747W3 |
6748 6748W3 |
6749 6749W3 |
6750 6750W3 |
6751 6751W3 |
6752 6752W3 |
||
14" (356MM) | 6754 6754W3 |
6755 6755W3 |
6756 6756W3 |
6757 6757W3 |
6758 6758W3 |
6759 6759W3 |
6760 6760W3 |
|||||
16" (406MM) | 6763 6763W3 |
6764 6764W3 |
6765 6765W3 |
6766 6766W3 |
6767 6767W3 |
6768 6768W3 |
6769 6769W3 |
6770 6770W3 |
||||
18" (457MM) | 6771 6771W3 |
6772 6772W3 |
6773 6773W3 |
6774 6774W3 |
6775 6775W3 |
6776 6776W3 |
6777 6777W3 |
|||||
20" (508MM) | 6778 6778W3 |
6779 6779W3 |
6780 6780W3 |
6781 6781W3 |
6782 6782W3 |
6783 6783W3 |
||||||
22" (559MM) | 6784 6784W3 |
6785 6785W3 |
6786 6786W3 |
6787 6787W3 |
6788 6788W3 |
|||||||
24" (610MM) | 6789 6789W3 |
6790 6790W3 |
6791 6791W3 |
6792 6792W3 |
||||||||
26" (660MM) | 6793 6793W3 |
6794 6794W3 |
6795 6795W3 |
|||||||||
28" (711MM) | 6796 6796W3 |
6797 6797W3 |
||||||||||
30" (762MM) | 6798 6798W3 |
* Rectangular Damper Dimension = Nominal width + 3.5"
Bottom Mount (Motor mounted on long dimension)
NOMINAL WIDTH (IN INCHES) | STOCK NO. | ||||||||
---|---|---|---|---|---|---|---|---|---|
8" | 10" | 12" | 14" | 16" | 18" | 20" | 22" | 24" | |
8" (203MM) | 6721 6721W3 |
6812 6812W3 |
6813 6813W3 |
6814 6814W3 |
6815 6815W3 |
6816 6816W3 |
6817 6817W3 |
6818 6818W3 |
6819 6819W3 |
10" (254MM) | 6732 6732W3 |
6823 6823W3 |
6824 6824W3 |
6825 6825W3 |
6826 6826W3 |
6827 6827W3 |
6828 6828W3 |
6829 6829W3 |
|
12" (305MM) | 6743 6743W3 |
6834 6834W3 |
6835 6835W3 |
6836 6836W3 |
6837 6837W3 |
6838 6838W3 |
6839 6839W3 |
* Rectangular Damper Dimension = Nominal width + 3.5"
Round Damper Size & Stock No.
Zone Damper (Normally open/ power closed) / W3 indicates power open/power closed
NOMINAL DIAMETER (IN INCHES) | STOCK NO. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
4" | 5" | 6" | 7" | 8" | 9" | 10" | 12" | 14" | 16" | 18" | 20" | |
4" (102MM) | 6606 6606W3 |
|||||||||||
5" (127MM) | 6607 6607W3 |
|||||||||||
6" (152MM) | 6608 6608W3 |
|||||||||||
7" (178MM) | 6609 6609W3 |
|||||||||||
8" (203MM) | 6610 6610W3 |
|||||||||||
9" (229MM) | 6612 6612W3 |
|||||||||||
10" (254MM) | 6614 6614W3 |
|||||||||||
12" (305MM) | 6616 6616W3 |
|||||||||||
14" (356MM) | 6618 | |||||||||||
16" (406MM) | 6620 | |||||||||||
18" (457MM) | ||||||||||||
20" (508MM) |
* Round Damper Dimension = Nominal diameter + 4.5"
Ventilation Damper (Normally closed/ power opened)
TYPE | NOMINAL DIAMETER (IN INCHES) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
4" | 5" | 6" | 7" | 8" | 9" | 10" | 12" | 14" | 16" | 18" | 20" | |
Barometric Pressure Relief (Air flow activated) | 6506 H: 10 3/4" | 6508 H: 10 3/4" | 6510 H: 10 3/4" | 6512 H: 10 3/4" | 6514 H: 10 3/4" | 6516 H: 12 3/4" | 6518 H: 14 3/4" | 6520 H: 16 3/4" | ||||
Static Pressure Relief (Power activated) | 6108 H: 10 3/4" | 6110 H: 10 3/4" | 6112 H: 10 3/4" | 6114 H: 12 3/4" | 6116 H: 14 3/4" | 6118 H: 16 3/4" | 6120 H: 19 31/50" | |||||
Round Slip-In Damper (Normally open/ power closed) | 6704 W: 3 4/5" H: 12 3/5" D: 7 3/10" | 6705 W: 3 4/5" H: 12 3/5" D: 8 3/10" | 6706 W: 3 4/5" H: 12 3/5" D: 9 3/10" | 6707 W: 3 4/5" H: 12 3/5" D: 10 3/10" | 6708 W: 3 4/5" H: 12 3/5" D: 11 3/10" | 6710 W: 3 4/5" H: 12 3/5" D: 13 3/10" | 6712 W: 3 4/5" H: 12 3/5" D: 14 3/10" | 6714 W: 3 4/5" H: 12 3/5" D: 16 3/10" | 6716 W: 3 4/5" H: 12 3/5" D: 18 3/10" | 6718 W: 3 4/5" H: 12 3/5" D: 20 3/10" | 6720 W: 3 4/5" H: 12 3/5" D: 22" |
Note: 10 day lead time for shaded items.
Fresh Air Ventilation
Ventilators and Ventilating Dehumidifiers are part of the AprilAire Healthy Air System.
Ventilation Systems
VENTILATION SYSTEMS | UNIT SIZE (W x H x L) | SHIPPING WEIGHT (LBS.) | AIRFLOW 0.2 IN. W.C. (@ CFM) | DESCRIPTION |
---|---|---|---|---|
VENTILATING DEHUMIDIFIERS #E100V + 8190FF |
14 1/2" x 23 1/2" x 48 1/4" | 82.00 (E100V) 16.80 (8190FF) |
150 | The Ventilating Dehumidifier (Models E100V + 8190FF) brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air. Fresh air is brought in whenever the HVAC system or dehumidifier is running to meet that need. If the required time is not met through these run cycles, the ventilating dehumidifier will bring in fresh air and remove any excess humidity. |
FRESH AIR VENTILATORS #8145 / #8145NC |
12 1/4" x 11 3/4" x 23 2/5" | 15.00 | 180 | The 8145 or 8142A deliver fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature a ventilation controller integrated into the unit. NC models do not include an on-board controller so that ventilation can be controlled via thermostat. |
#8142A | 13 1/5" x 6 7/10" x 11 9/10" | 11.50 | 220 | The 8145 or 8142A deliver fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature a ventilation controller integrated into the unit. NC models do not include an on-board controller so that ventilation can be controlled via thermostat. |
#8144NC | 10 1/4" x 18 1/8" x 10 1/4" (D) | 20.50 | 130 | The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120X ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions. |
Ventilation Controllers
CONTROLLER | SIZE (W x H x D) | DESCRIPTION | ||
---|---|---|---|---|
#8120X | 4 11/100" x 3 3/5" x 1 59/100" | The 8120X engages a fan or damper on ventilation solutions to deliver fresh air to return duct. It can provide fresh air within set high/low outdoor temperature and indoor RH limits. | ||
#8126X (SYSTEM) | DAMPER H: 10 3/4" DIA: 10 8/25" 8120X CONTROL W: 4 11/100" H: 3 3/5" D: 1 59/100" |
The AprilAire Model 8126X Ventilation Control System includes the 8120X ventilation controller, damper, 24VC transformer, outdoor temperature sensor and duct board bracket for 8120X. The ventilation system measures outdoor temperature to stop ventilation at adjustable high and low outdoor temperature lockouts. | ||
#KV08 | W: 8" H: 10 3/4" D: 12 1/3" | |||
#KV10 | W: 10" H: 10 3/4" D: 14 1/3" |
Kitchen Ventilation Kits
The KV08, KV10 Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects.
ENERGY RECOVERY VENTILATOR (ERV)
MODEL | UNIT SIZE (W x H x D) | SHIPPING WEIGHT (LBS.) | AIRFLOW @ 0.2 IN. W.C. (CFM) | DESCRIPTION |
---|---|---|---|---|
#V22BEC | 27 1/2" x 23 1/8" x 9" | 50.00 | 118 | The V22BEC replaces stale, indoor air with fresh, outdoor air from a known location. It reduces costs associated with ventilation by recovering conditioned air when ventilating, protects comfort by tempering incoming ventilation air, and reduces heating and cooling loads by managing temperature and humidity of incoming air. |
Accessories
ACCESSORIES | PRODUCT DESCRIPTION | UNIT SIZE | TYPE OF WIRE | COMPATIBLE MODELS |
---|---|---|---|---|
#8051 | Flush Mount Sensor: Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall. | Disk: 1 1/2" dia. Friction fit in a 1" opening. Air gap of 1/4" required. |
8600 8620 8620W S84NSU S86NMU S86NMUPR S86WMUPR 8910 8910W 8920W 8800 8820 8830 8840 | |
#8052 | Outdoor/Duct Sensor: Designed for outdoor or duct installation including with use of zone control panels. | Probe: 1/4" dia. x 1 3/4" L Bracket: 3/4" x 3/4" |
18-24 gauge 2 conductor wire (or more conductors) | All zone control panels |
#8053 | Surface Mount Sensor: Perfect for light indoor commercial applications to prevent tampering. | W: 3 1/2" H: 2 1/2" D: 7/8" | All thermostats | |
#8022 | 3-Wire to 4-Wire Adapter: Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system. | W: 2 7/8" H: 1 3/4" D: 1 47/50" | All thermostats | |
#8028 | Damper Power Distribution Panel: For applications where needed dampers outnumber control capability of any AprilAire Zone Control Panel. | W: 10 1/2" H: 5" D: 1 7/10" | 18-22 gauge stranded or solid thermostat wire can be used for all wire runs | All zone control panels |
#6401 | Expansion Panel: Two-zone expansion panel that supports 2-wire or 3-wire dampers. | W: 10 1/2" H: 5" D: 1 7/10" | 6404 |
Automation Modules
AUTOMATION MODULES | PRODUCT DESCRIPTION | UNIT SIZE | TYPE OF WIRE | COMPATIBLE MODELS |
---|---|---|---|---|
#8082 | Temperature and RH Support Module: Averages four temperatures (on-board or offboard) and four humidity values (on-board only). | W: 3 1/2" H: 2 1/2" D: 7/8" | Cat 6 or greater | 8800 8840 |
#8083 | Flush Temperature and RH Support Module: Averages four temperature and four RH values. | Disk: 1 1/2" dia. Cylinder Hole: 1" off wall, 1/4" air gap |
Cat 6 or greater | 8800 8840 |
Ventilation Climate Zones
Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. The requirements change significantly based on climate. AprilAire ventilation solutions work with the HVAC equipment to remove moisture, harmful particulates and other contaminants such as VOCs. It's critical to use intelligent ventilation controls and application guidance to properly ventilate rather than relying on exhaust ventilation which simply pulls air through walls.
Climate Zone Map Description: The map displays climate zones (1-7) based on factors including mean temperature, warmest month, precipitation, and wet bulb temperature, referencing the 2012 & 2015 International Residential Code §N1101.10 (R301.1). Zones are categorized as Marine, Dry, Moist, Warm & Moist, Warm & Dry, Mixed & Moist, Mixed & Dry, Mixed & Marine, Cool & Moist, Cool & Dry, Cold & Moist, Cold & Dry, and Extreme Cold & Moist.
Ventilation Supply Solutions - AprilAire Ventilation Application Matrix
Use this map and the adjoining application guide to determine the recommended product solution for your climate. These recommendations are based on moisture removal demands, energy savings and integration with the HVAC equipment.
ZONE | CLIMATE TYPE | MAJOR CITIES | PRIMARY SOLUTION1 | ECONOMY- OR COMFORT- FOCUSED SOLUTION | MULTI-FAMILY NEW CONSTRUCTION SOLUTION |
---|---|---|---|---|---|
1 | Hot & Moist | Miami | E100V + 8190FF | 8145 or 8126X | 8144NC |
2 | Hot & Moist | Orlando, Mobile, New Orleans, Houston, Austin, San Antonio | E100V + 8190FF | 8145 or 8126X | 8144NC |
2 | Hot & Dry | Phoenix, Tucson | 8142A | 8126X | 8144NC |
3 | Warm & Moist | Charlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFW | E100V + 8190FF or V22BEC | 8145 or 8126X | 8144NC |
3 | Warm & Dry | El Paso, Las Vegas, Los Angeles, Sacramento | 8142A or V22BEC | 8126X | 8144NC |
3 | Warm & Marine | San Francisco, San Jose | 8145 or V22BEC | 8145 or 8126X | 8144NC |
4 | Mixed & Moist | Philadelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville | 8145 or V22BEC | E100V + 8190FF or 8126X | 8144NC |
4 | Mixed & Dry | Albuquerque, Amarillo | 8142A or V22BEC | 8145 or 8126A | 8144NC |
4 | Mixed & Marine | Portland, Seattle | 8142A or V22BEC | 8126A | 8144NC |
5 | Cool & Moist | Boston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha | 8145A or V22BEC | 8145 or 8126C | 8144NC |
5 | Cool & Dry | Denver, Salt Lake City, Boise, Reno | 8145 or V22BEC | 8142A or 8126A | 8144NC |
6 | Cold & Moist | Toronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls | 8145 or V22BEC | 8126A | 8144NC |
6 | Cold & Dry | Helena, Cheyenne | 8145 or V22BEC | 8142A or 8126A | 8144NC |
7 | Extreme Cold & Moist | Fargo, Duluth, Calgary, Edmonton | 8145 | 8126A | 8144NC |
1 Primary AprilAire recommended supply ventilation solution for optimal performance and building code adherence.
2 HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.
The AprilAire Healthy Air System
Who doesn't want greater health, virus protection, fewer allergens, more productivity and better sleep? Fill your home with Healthy Air today.
Download the APP
The AprilAire Healthy Air App works with your AprilAire connected devices and provides you with a powerful level of control--no matter where you are. Compatible with AprilAire Wi-Fi thermostats.