Dasqua IP67 Digital Caliper

Product Instructions

Guidelines to Ensure Performance

⚠️ Safety Instructions

Specifications

Cleaning

After each use, wipe the caliper clean with a soft, dust-free cloth. DO NOT use any type of solvent.

Product Structures

Diagram showing the parts of the digital caliper:

Usage Instructions

I. Preparation Steps

  1. Rotate the locking screw clockwise to loosen the caliper and release the lock. The caliper can then be moved manually.
  2. Turn on the caliper to check if the display and buttons are functioning.
  3. Clean the measuring surfaces. Close the measuring jaws with appropriate force and briefly press the 0/0 button to turn on and set the zero point.

II. Measurement Operation

  1. Press the power button or slide the caliper frame to illuminate the display.
  2. Press the Metric/Inch button to select the desired measurement unit based on requirements.
  3. Move the caliper frame so that the measuring surfaces of the two jaws are in close contact with the object's surfaces. Read the value displayed on the screen.

Modes:

Normal Mode: Upon powering on, the display shows the slider's position from before the last shutdown. The zero position (origin) is the last set zero position. No adjustment is needed for absolute measurement mode. For relative measurement mode, press the INC button to set the zero position (non-origin) as needed.

Power Saving Mode (Shutdown after 8+ hours): Upon powering on, the absolute measurement zero position is the caliper frame's position at startup. After cleaning the measuring surfaces, close the jaws and long-press the 0/0 button for five seconds to reset the absolute measurement mode's zero position.

III. Switching Between Absolute and Relative Measurement

Relative Measurement: Briefly press the INC button. The 'INC' indicator appears on the left of the LCD. The caliper enters INC memory measurement, resets to zero, and starts counting from the position where the INC button was pressed.

Absolute Measurement: In relative measurement mode, press the INC button again. The 'INC' indicator disappears, returning to absolute mode. Counting resumes from the zero position set at startup.

Installing / Replacing the Battery

Follow these steps for battery installation/replacement (refer to Figure 1):

  1. Always use a CR2032 3V battery.
  2. The supplied batteries are for function checking only and may not meet the specified battery life.
  3. Step 1: Using provided tools, remove battery compartment screws.
  4. Step 2: Use the provided tool to gently pull out the battery compartment.
  5. Step 3: Insert the battery with the positive (+) side facing up.
  6. Step 4: Insert the compartment lid with the battery. Use provided tools to secure the screws.
  7. Step 5: Installation is complete.

Low Battery Indicator: Flashing digits on the LCD indicate low battery power. Replace the battery.

Long-Term Storage: If the caliper will not be used for over a month, remove the battery and store it properly to prevent leakage and damage.

Troubleshooting

ProblemSolution
No DisplayCheck battery contacts or replace the battery.
Digits do not display correctlyReset the caliper: Remove the battery for 30 seconds, then reinstall and power on.
Digits flashingBattery power is low; replace the battery.

Disposal Guide

Disposal of Old Electrical and Electronic Equipment (Applicable in the European Union and other European Countries with separate collection systems):

  1. The symbol on the product or packaging is based on the WEEE directive, indicating it should not be treated as household waste.
  2. To reduce environmental impact and landfill volume, please cooperate in reuse and recycling.
  3. Consult local regulations and instructions for product disposal.
  4. Recycle batteries at your local recycling facility.
Models: 2015-2415, IP67 Digital Caliper, IP67, Digital Caliper, Caliper

PDF preview unavailable. Download the PDF instead.

mode-demploi-2986862-dasqua-2015-2410-2015-2410-pied-a-coulisse-numerique-200-mm-ip67 Corel PDF Engine Version 23.1.0.389 CorelDRAW 2021

Related Documents

Preview Dasqua Precision Digital Caliper: User Manual & Instructions
Comprehensive guide for Dasqua digital calipers, covering usage, safety, specifications, troubleshooting, and battery replacement. Learn how to operate and maintain your Dasqua digital caliper for accurate measurements.
Preview Dasqua Digital Outside Micrometer: Product Instructions and Specifications
Detailed product instructions and specifications for the Dasqua Digital Outside Micrometer, covering its structure, keys, LCD display, operation, power requirements, safety precautions, and troubleshooting guide.
Preview Dasqua Digital Gauge Instruction Manual
Instruction manual for the Dasqua Digital Gauge, detailing use steps, product characteristics, specifications, and important cautions. Includes model numbers TD230A, TD230B, TD230C.
Preview Dasqua IP67 Digital Dial Caliper Product Instructions
Comprehensive instructions for the Dasqua IP67 Digital Dial Caliper, covering performance guidelines, disposal, troubleshooting, specifications, and operation instructions.
Preview Dasqua Vernier/Dial Caliper Instruction Manual
Instruction manual for Dasqua Vernier and Dial Calipers, covering structures, reading measurements, common usage, special caliper usage, precautions, and troubleshooting.
Preview Dasqua Digital Caliper User Manual and Specifications
Comprehensive guide for the Dasqua Digital Caliper, covering usage instructions, safety guidelines, specifications, troubleshooting, and disposal information. Includes details on battery installation and maintenance.
Preview Dasqua IP65 Waterproof Digital Outside Micrometer: Product Instructions
Comprehensive product instructions for the Dasqua IP65 Waterproof Digital Outside Micrometer, covering usage, structure, buttons, battery, troubleshooting, and precautions.
Preview SB-009 Digital Level Box: Safety and Operating Instructions
Comprehensive safety, handling, and disposal instructions for the Dasqua SB-009 Digital Level Box. Learn about proper usage, battery care, and environmental disposal.