Aprilaire 8192A Fresh Air Ventilator with Dehumidification
Specification Sheet
Product Overview
The Aprilaire Model 8192A is a Fresh Air Ventilator with Dehumidification designed to improve indoor air quality by removing moisture from incoming outdoor air and providing controlled ventilation. It is engineered to meet stringent building standards and offers energy-efficient operation.
[Image Description: A front-side view of the Aprilaire Model 8192A unit, a rectangular appliance with a prominent fan grille on the right side, air intake and discharge ports, and a control panel on the front.]
Specifications
Specification | Value |
---|---|
Nominal ventilation airflow (CFM) | 200 CFM |
Capacity(1) pints/day | 100 ppd |
Energy factor(1) | 2.6 L/kWh |
Energy star qualified | No |
Airflow @ varying E.S.P. (external static pressure - dry coil) | 0.0" w.c.: 280 CFM |
0.2" w.c.: 245 CFM | |
0.4" w.c.: 210 CFM | |
Voltage, phase, frequency | 120VAC, 1, 60 Hz |
Current draw(1) | 6.9 Amps |
Noise-Fan Only | 52.8 dBA (ducted) |
Noise-Compressor and Fan | 55.0 dBA (ducted) |
Dimensions | Width: 14" | Height: 15" | Length: 26" |
Unit Weight | 64 lbs. |
Shipping Weight | 82 lbs. |
Inlet air operating conditions during | -Dehumidification: 50°F–104°F, 40°F dew point min. |
-Ventilation: 40°F–140°F, 0%–99% RH |
(1)Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(3)Thread adapter and barbed fitting for 3/4" clear drain tubing included.
Features
- Removes moisture from outdoor air before it enters the living space
- Unit is designed, when properly installed, to achieve ASHRAE Standard 62.2
- Integral moisture and ventilation control
- Optional ventilation control via thermostat (see below)
- High and Low Temperature Limit Lock-outs
- Simple plug-in installation
- Installation temperature range up to 140°F
Recommended Controls
- Aprilaire Thermostat Models: 8620, 8620W, 8910, 8910W, 8920W
- Aprilaire Communicating Thermostat Models: 8820, 8830, 8840
- Zone Control Systems: 6010, 6015, 6020, 6025, 6030, 6035, 6040, 6045
Benefits
- Helps control RH in the home during periods when the air conditioning system does not run long enough to remove sufficient moisture. If air conditioner can satisfy RH requirements, the Aprilaire unit's compressor shuts off.
- Optimizes energy savings by locking out ventilation during hottest/coldest times of the day.
- Improves indoor air quality.
- Installation labor is reduced, requiring only a power outlet and 24 volt wiring to the HVAC system.
Compliance
When properly installed and set, the Aprilaire Model 8192A ventilator with dehumidification will meet the mechanical ventilation requirements of:
- ASHRAE 62.2
- Energy Star Certified Homes
- EPA Indoor airPLUS
- International Residential Code (IRC)
Product Dimensions and Views
[Diagram Description: Orthographic views of the Aprilaire 8192A unit. Front view shows width of 14 inches. Side view shows height of 15 inches and length of 26 inches, with a 3/4 inch diameter pipe connection. Top view shows a 10 inch diameter duct collar.]
Control Panel Interface
[Diagram Description: The control panel features an ON/OFF button to power the ventilator on and off. A MODE button is used to access ventilation time settings. A central display shows the current SETTING. UP/DOWN buttons are used to adjust humidity or vent time settings.]
Ducting the Ventilator
[Diagram Description: A schematic illustrating the ducting of the Aprilaire ventilator. It shows a fresh air intake hood with a screen connected via a 10x6 round transition to the dehumidifier/ventilator unit. A filter is located after the ventilator. The unit connects to a furnace/air handler via a return mixing box and a 10-inch diameter duct. The system includes a Model 6506 normally closed damper for fresh air intake.]
Installation can be in a gable end wall, band joist, or porch soffit.
Warranty and Manufacturing
[Graphic Description: A circular badge indicating "5 YEAR WARRANTY" and "MADE IN THE USA".]