MEAN WELL XDR-75E Series: 75W AC/DC Economical Ultra Slim Industrial DIN Rail Power Supply
User's Manual
Overview
The XDR-75E series is a 75W AC/DC economical ultra-slim industrial DIN rail power supply. It features a narrow 30mm casing for optimized system installation space and an ultra-wide input range of 85~264Vac for global use. The series boasts a maximum efficiency of 91% and a low standby power consumption of less than 1W. It includes built-in constant current limiting, a fanless design for free air convection, and a wide operating temperature range of -40 to +70℃ (with derating above +50℃). It complies with OVCIII, offers a built-in DC OK signal, and comes with comprehensive protection functions, complete safety certifications, and a 3-year warranty.
Features
- 85~264Vac input range
- Global certificates in multi-fields (ITE 62368-1, Industrial 61558-1/-2-16, 61010)
- 30mm slim width
- High efficiency up to 91% and no load power dissipation <1W
- Built-in constant current limiting circuit
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Fanless design, cooling by free air convection
- Over voltage category III (OVC III)
- -40~+70°C wide range operation temperature (>+50°C derating)
- Operating altitude up to 5000 meters
- Built-in DC OK relay contact
- Can be installed on DIN rail TS-35/7.5 or 15
- 3 years warranty
Applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
- Battery charger
- Telecom
- Automate Industrial Security Network
Model Encoding
XDR - 75 E - [Output voltage]
Example: XDR-75E-24 indicates a 24V output voltage model.
Specifications
Specification | XDR-75E-12 | XDR-75E-24 | XDR-75E-36 | XDR-75E-48 |
---|---|---|---|---|
DC VOLTAGE | 12V | 24V | 36V | 48V |
RATED CURRENT | 6.3A | 3.2A | 2.1A | 1.6A |
CURRENT RANGE | 0~6.3A | 0~3.2A | 0~2.1A | 0~1.6A |
RATED POWER | 75.6W | 76.8W | 75.6W | 76.8W |
RIPPLE & NOISE (max.) | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p |
VOLTAGE ADJ. RANGE | 12~15V | 24~29V | 36~42V | 48~55V |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
SETUP, RISE TIME | 1200ms, 60ms/230Vac | 2500ms, 60ms/115Vac at full load | ||
HOLD UP TIME (Typ.) | 16ms/230Vac | 10ms/115Vac at full load | ||
AC VOLTAGE RANGE | 85~264Vac | |||
DC VOLTAGE RANGE | 120~370Vdc | |||
NO LOAD POWER CONSUMPTION (Typ.) | 0.5W @115Vac | 0.7W @230Vac | 0.8W @115Vac | 0.9W @230Vac |
FREQUENCY RANGE | 47~63Hz | |||
EFFICIENCY (Typ.) | 89% | 90% | 91% | 91% |
AC CURRENT (Typ.) | 1.4A/115Vac, 0.8A/230Vac | |||
INRUSH CURRENT (Typ.) | COLD START 18A/115Vac, 35A/230Vac | |||
LEAKAGE CURRENT | <1mA/240Vac | |||
OVERLOAD | 105-130% rated output power, constant current limiting without shutdown, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 15~18V | 30~34V | 43~50V | 56~65V |
OVER TEMPERATURE | Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||
DC OK RELAY CONTACT | Relay Contact Ratings (max.): 30Vdc/1A, 30Vac/0.5A resistive load. | |||
WORKING TEMP. | -40~+70°C (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20~95% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95% RH non-condensing | |||
TEMP. COEFFICIENT | ±0.03% /°C (0~50°C) | |||
VIBRATION | Component:10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||
SAFETY & EMC | Note.6 | |||
SAFETY STANDARDS | UL61010; TUV BS EN/EN62368-1, BS EN/EN61558-1/-2-16, BS EN/EN61010; CB IEC62368-1, IEC61558-1, IEC61010; RCM AS/NZS 62368-1, AS/NZS 61558-1/-2-16; BSMI CNS15598-1; CCC GB4943.1; EAC TPTC004 approved; KC KC62368-1 and BIS IS13252 (Part 1):2010 certified. | |||
OVER VOLTAGE CATEGORY | IEC/EN 61558-1/-2-16 (OVC III, altitude up to 2000m); IEC/EN/UL 61010 (OVC II, altitude up to 5000m); IEC/EN 62368-1 (OVC II, altitude up to 5000m) | |||
SAFETY EXTRA-LOW VOLTAGE(SELV) | IEC/EN 61558-2-16 (SELV); IEC/EN/UL 61010-2-201 (SELV / ES1); IEC/EN 62368-1 (SELV / ES1) | |||
WITHSTAND VOLTAGE | I/P-O/P: 4KVac I/P-FG: 2KVac O/P-FG: 1.5KVac O/P-DC OK: 0.5KVac | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25°C/70%RH | |||
EMC EMISSION | Parameter | Standard | Test Level/Note | |
Conducted | BS EN/EN55032 (CISPR32) / BS EN/EN61204-3/CNS15936 | Class B | ||
Radiated | BS EN/EN55032 (CISPR32) / BS EN/EN61204-3/CNS15936 | Class B | ||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||
Voltage Flicker | BS EN/EN61000-3-3 | --- | ||
EMC IMMUNITY | Parameter | Standard | Test Level/Note | |
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact; criteria A | ||
Radiated | BS EN/EN61000-4-3 | Level 3, 10V/m; criteria A | ||
EFT/Burst | BS EN/EN61000-4-4 | Level 3, 2KV; criteria A | ||
Surge | BS EN/EN61000-4-5 | Level 4, 2KV/Line-Line ; Level 4, 4KV/Line-Line-Chassis ; criteria A | ||
Conducted | BS EN/EN61000-4-6 | Level 3, 10V; criteria A | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m; criteria A | ||
MTBF | 2425.7K hrs min. Telcordia SR-332 (Bellcore); 533.7K hrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 30*125.2*116mm (W*H*D) | |||
PACKING | 400g; 24pcs/10.6Kg/1.16CUFT |
Block Diagram
Derating Curve
Static Characteristics
Function Manual: DC OK Relay Contact
The DC OK relay contact indicates the status of the power supply output:
- Contact Close: PSU turns ON / DC OK
- Contact Open: PSU turns OFF / DC Fail
- Contact Ratings (max.): 30Vdc/1A, 30Vac/0.5A resistive load.
Mechanical Specification
Dimensions: 30mm (W) * 125.2mm (H) * 116mm (D)
Mounting: Fits DIN rail TS35/7.5 or TS35/15.
Recommend Wiring
AC Input T.B | DC Output T.B | Signal connector | |
---|---|---|---|
Solid Wire | 6mm² max. | 6mm² max. | 1.5mm² max. |
A.W.G | 18~10 AWG | 18~10 AWG | 24~16 AWG |
Wire Stripping Length | 7~8mm | 7~8mm | 8~9mm |
Screw Terminal Torque | 5 Lb-in | 5 Lb-in | / |
Installation Instruction
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the Instruction manual available at: www.meanwell.com/manual.html