Philips Dynalite DLPE Standard Series Button Panel

Installation Instructions

General Safety Information

Warning: Devices must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

Les appareils doivent être installés par un électricien diplômé conformément à tous les codes et réglementations électriques et de construction nationaux et locaux.

Die Geräte sind von einem qualifizierten Elektriker in Übereinstimmung mit allen geltenden Vorschriften zu installieren.

Los dispositivos deben ser instalados por un electricista calificado y cumpliendo todas las normas y regulaciones, tanto nacionales como locales, sobre instalaciones eléctricas y obras.

I dispositivi devono essere installati da un elettricista qualificato in conformità con le norme locali e nazionali vigenti in materia di costruzioni edilizie e installazione di impianti elettrici.

De apparaten moeten worden aangebracht door een gekwalificeerde elektricien en in overeenstemming met alle nationale en plaatselijke elektriciteits- en bouwvoorschriften.

装置を取り付ける際は、資格のある電気技師に依頼し、国および地域の電気および建設に関するすべての法令に従ってください。

根据国家/地区及当地的电气与建筑规范和法规,该设备必须由有资质的电工进行安装。

يجب تركيب الأجهزة من قبل فني كهربائي مؤهل وفقًا لكافة قوانين ولوائح التركيب الكهربائي المحلي والوطني.

Installation Steps

  1. Step 1: Prepare the mounting location. The button panel requires a standard electrical box. The dimensions for the panel are 87 mm (3.42 in) width and 87 mm (3.42 in) height, with a depth of 34 mm (1.33 in).

    Diagram Description: Shows a screwdriver being used to attach the mounting bracket to a wall or surface, with the DLPE unit nearby.

  2. Step 2: Mount the back box and attach the wiring. Ensure all connections are secure and comply with local electrical codes.

    Diagram Description: Illustrates the DLPE unit being mounted onto the prepared back box, with wires being connected to terminals labeled '+V', 'DATA-', 'DATA+', 'GND', and 'SHLD'. The wiring diagram shows connections for RS-485 DyNet, with specifications for wire gauge (0.3-2.5mm² / 22-12 AWG) and torque (0.4 Nm / 3.5 Lb-in).

Technical Specifications and Compliance

Federal Communications Commission (FCC) Compliance Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any modifications not approved by the manufacturer of this device could void the user's authority to operate this device.

Canadian Compliance: This Class B digital apparatus complies with Canadian ICES-003: CAN ICES-3(B)/NMB-3(B).

Important Note: Do not connect inputs to mains.

Manufacturer Information

© 2021 Signify Holding. All rights reserved.

Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.

For more information, visit: www.lighting.philips.com/dynalite

Models: DLPE, Standard Series Button Panel

File Info : application/pdf, 2 Pages, 937.72KB

PDF preview unavailable. Download the PDF instead.

DYN DLPE II-R13

References

Adobe PDF Library 15.0 Adobe InDesign 16.3 (Macintosh)

Related Documents

Preview Philips Dynalite DR2PE Revolution Series Button Panel Installation Instructions
Comprehensive installation guide for the Philips Dynalite DR2PE Revolution Series Button Panel, detailing electrical connections, safety requirements, environmental specifications, and regulatory compliance.
Preview Philips Dynalite DDTC001 Network Timeclock Installation Guide
Comprehensive installation guide for the Philips Dynalite DDTC001 Network Timeclock, detailing wiring, safety precautions, and device specifications for professional electricians.
Preview Philips Dynalite Product Portfolio: Intelligent Lighting Control Solutions
Explore the comprehensive Philips Dynalite Product Portfolio, featuring advanced lighting control systems for diverse applications. Discover user interfaces, controllers, and network devices designed for intelligent and efficient lighting management.
Preview Philips Dynalite PDRDE Revolution Display Euro Installation Guide
Concise installation instructions for the Philips Dynalite PDRDE Revolution Display Euro, covering electrical connections, mounting, and safety compliance. Optimized for search engines.
Preview Philips Dynalite PDRXA Installation Guide
Detailed installation instructions for the Philips Dynalite PDRXA lighting control system component, covering safety, wiring, mounting, and compliance information.
Preview Philips Dynalite DMRC210 Relay Controller Installation Instructions
Installation instructions for the Philips Dynalite DMRC210 Relay Controller, detailing electrical connections, wiring, and mounting procedures for qualified electricians.
Preview Philips Dynalite DDBC300-D DALI Driver Controller Installation Guide
Official installation instructions for the Philips Dynalite DDBC300-D DALI Driver Controller, detailing electrical connections, dimensions, and safety precautions for professional installation.
Preview Philips Dynalite DDRC1220FR-GL Relay Controller Installation Instructions
Comprehensive installation guide for the Philips Dynalite DDRC1220FR-GL Relay Controller, detailing electrical connections, wiring, and safety precautions for qualified electricians.