General Characteristics
References | 65345106 / 65004410 / 65020015 / 65020020 |
Dimensions (H x W x D) (mm) | 11400 x 360 x 240 |
Material | Steel 2.2 mm |
Standard Color | Body: Ral 6018 / Cover: Ral 9016 for 65345106 / 65004410 Body: Ral 6018 / Cover: Ral 9016 for 65020015 / 65020020 |
Steel Treatment | Anti-corrosion (KTL) and powder coating |
Weight (kg) | 76 kg |
Number of charging points | 2 |
Socket | Type 2 |
Cable | Type 2 |
Connector housing | Type 2 |
Cable (for specific models) | Type 2 |
Electrical Characteristics
Power per socket | 0 to 44kW |
Service Voltage (Ue) / Rated Current (In A) per charging station | Single-phase wiring, phase + N 230V~ from 0 to 125A (determined at 20°C) Three-phase wiring, 3 phases + N 400V~ from 0 to 125A (determined at 20°C) |
Service Voltage (Ue) / Rated Current (In A) per charging point | Single-phase wiring, phase + N 230V~ from 0 to 63A (determined at 20°C) Three-phase wiring, 3 phases + N 400V~ from 0 to 63A (determined at 20°C) |
Impulse Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Rated Voltage | 1 phase + N: 230V - 3 phases + N: 400V |
Voltage Tolerance (V) Independent of vehicle requirements | 195V - 265V |
Integrated Protection System on Charging Station | Main circuit breaker 125A |
Integrated Protection System per Charging Point | MCB 80A curve C RCD 63A 30mA Type B |
Conditional Short-Circuit Current | 6000A IEC/EN 60898-1 10kA IEC/EN 60947-2 |
Admissible Thermal Stress in Case of Short-Circuit | 16 000 A²s |
Grid Connection | Phase/Neutral, rigid cable, 2.5 to 50 mm², screw terminals H07 V R/U Earth, rigid cable, 2.5 to 50mm², screw terminals H07 V R/U |
Charging Type | Charging station Mode 3 equipped with a locking system for Mode 3 |
Connection to Vehicle | Mode 3 cable connector attached Type 2 3P+N (single-phase compatible) with pilots compliant with IEC 62191-1 and IEC 62196-2 standards. Use of extension cords and adapters is prohibited. 10m straight 3x63A |
Phase Rotation on Channel 2 (right side) | In the case of single-phase wiring (Ph+N) on the power supply. Channel 2 cannot start charging sessions until the phase rotation between the contactor and the socket is manually canceled. |
AC Meters | MID certified, Class B according to EN 50470-1, -3 |
Back Office Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 connector for 65345106 / 65020020 |
Environment
Service Temperature | -25°C / +50°C |
Storage Temperature | -25°C / +80°C |
Relative Humidity | 0 to 90 without condensation |
Corrosivity Class | C4 according to IEC 9223 and IEC 12944 3C3/4C3 according to IEC 60721-3 |
Protection Index | IP 54 (IEC 60529), IK 10 (EN 62262) Connected or not |
Noise Level | < 40 dBA at 1m |
Product Installation | Indoor or outdoor, limited access area, intended for use by ordinary persons (DBO), cabinet mounting (wall-mounted), pollution degree 3, TNS, TT, compatible earthing. In case of IT earthing, it can be modified locally by adding an isolation transformer. |
Electrical Safety | Class 1 IEC 61140 |
Electromagnetic Compatibility
European Standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014/30/EU |
Radio Technology Type | GSM 2G/3G/4G, GPRS, RFID |
Compatible Recharge Cards | Mifare, Ntag and iCODE SLI cards |