VOCOlinc VH1 MistFlow Smart Humidifier
Product Overview and User Guide
Description
The VOCOlinc VH1 MistFlow Smart Humidifier/Diffuser is compatible with Apple HomeKit, Amazon Alexa, and the Google Assistant. Users can check its status or control it wirelessly via voice commands or the VOCOlinc/Home app using a 2.4GHz Wi-Fi network.
It features a customizable rainbow-spectrum mood light, allowing users to select colors suitable for their mood or occasion. Automation features include scheduling, auto-target humidity, and various light effects.
The MistFlow enhances health and sleep for families. Its substantial capacity and mist output are ideal for medium-sized rooms and offices, covering up to 430 sq ft (40 sq m). The top-fill design simplifies cleaning and refilling.
Controls
The device features two primary touch controls:
- Control 1 (Mist): Tap to set mist level between High and Low. Long press to set the timer for 2, 4, or 6 hours.
- Control 2 (Light): Tap to turn the mood light on or off. Long press to cycle through and change the light color.
Key Components
The humidifier consists of several key parts:
- Lid
- Water Tank
- Water Level Indicator
Internal components include:
- Atomizer
- Air Outlet
- Water Level Sensor
- Power Cord
- Air Intake
- Water Outlet
Specifications
Feature | Details |
---|---|
Power Requirements | 120V AC 60Hz (US) / 220-240V AC 50Hz (EU) |
Operating Temperature | 1°C to 40°C / 33.8°F to 104°F |
Rated Power | 30 W |
Water Tank Capacity | 2.5 L |
Touch Button Functionality | Light / Mist control |
Wireless Network | Wi-Fi 2.4GHz 802.11 b/g/n |
Applicable Area | Up to 430 ft² / 40 m² |
Mist Level Control | High, Low (Touch Button); 1-5 Level (VOCOlinc app) |
Mood Light | RGB Rainbow Spectrum |
Firmware Update | OTA (requires VOCOlinc app) |
On-device LED Indicators | Power status, Mist level (High, Low) |
Power Cord Length | 4.92 ft or 150 cm |
Dimensions (mm) | 180 x 180 x 285 |
Weight (kg) | 1.1 |
Factory Reset
To perform a factory reset, simultaneously press and hold both the LIGHT and MIST buttons for 10 seconds. The mood light will blink and then illuminate, indicating the device is in pairing mode. Follow the instructions in the VOCOlinc/Home app to reconnect the device to your 2.4GHz Wi-Fi network.
What's Included
- VH1 MistFlow Smart Humidifier
- User Manual
Firmware Update
To ensure the best experience with VOCOlinc products, it is recommended to update the firmware when new versions are available. Follow these steps:
- Open the VOCOlinc app.
- Long press the device icon to access its main page.
- Locate "Firmware update" and tap "Update" when prompted.
Note: Firmware update notifications will only appear for devices that are currently reachable and have an available update. It is crucial to keep the VOCOlinc app running during the update process and avoid minimizing, closing, or interrupting it until the update is successfully completed to prevent potential issues.
Warnings
- The amount and intensity of mist produced can vary based on water type, water level, humidity, temperature, and air currents. These variations are normal and not considered faults.
- Only use 100% natural water-soluble essential oils. Oils containing chemical ingredients, artificial flavors, or impurities may damage the device.
- Always clean the water tank before switching to a different essential oil.
Accidental Leakage
If the unit is knocked over or tipped during use, follow these steps to prevent damage:
- Unplug the device and remove the cover.
- Empty any remaining water from the water tank.
- Gently shake out residual water and allow the device to air dry in an open space for at least 24 hours.
Maintenance
After continuous operation or every 3-5 days, clean the device as follows:
- Unplug the device and remove the cover.
- Empty any remaining water from the tank.
- Clean the device with warm water, adding a few drops of mild dishwashing detergent. Wipe gently with a dry cloth.
- Avoid using acids or enzyme-based detergents, as they can release hazardous gases or cause malfunctions. Always opt for a mild detergent.
- If the humidifier will not be used for an extended period, drain the water from the tank.
Regulatory Compliance
FCC Declaration
Caution: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
IC Declaration
Caution: This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. In order to avoid the possibility of exceeding the ISEDC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.
VOCOlinc App
Download the VOCOlinc app to control your smart humidifier:
Setup code: [Code de Configuration]