Rheem® Hybrid Electric Heat Pump Water Heater

Designed for Residential Builders to Maximize Energy Design Rating/HERS Rating

Product Highlights

Features & Benefits

Category Description
High Efficiency

ENERGY STAR® 5.0 certified

Helps builders earn 45L tax credits

Easy Installation

Easily Ducted - for installation in confined spaces with minimal make up air

Easy access to side water connection and top electrical junction box; Zero clearance required in the back or side of the unit

¾" NPT water inlet & outlet; ¾" condensate drain connections

Dry fire protection

Available EcoNet® Smart Technology

Integrated Wi-Fi Technology²

Energy usage reporting

Energy saving scheduling and operating modes

Note: ¹ See Residential Warranty Certificate for complete information. ² Wi-Fi broadband internet connection required. ³ Consult your tax advisor for details on eligibility requirements for any available tax credits. Rebates vary by state.

Specifications

Model Series: Hybrid Electric Heat Pump - Builder

Capacities: 40, 50, 65 and 80-Gallon

Electrical: 208-240 Volt / 1 PH / 24 Amps

LEED Points: 3

Nominal Gallon Capacity Rated Gallon Capacity Model Number Model Variant Electric Breaker Size Uniform Energy Factor (UEF) Compressor BTU/H First Hr. Rating G.P.H. Recovery G.P.H. 90° F Rise Unit Wt. (LBS) Approx. Ship Wt. (LBS.)
40 36 PRO H40 T2RH310BM 700461 30 3.50 4200 60 26 156 177
50 45 PRO H50 T2RH310BM 700455 30 3.50 4200 67 26 172 193
65 59 PRO H65 T2RH310BM 700456 30 3.50 4200 75 26 225 262
80 72 PRO H80 T2RH310BM 700457 30 3.50 4200 87 26 244 281

Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.

Dimensions

Diagram Description: The diagram illustrates the physical dimensions of the Rheem Hybrid Electric Heat Pump Water Heater Builder Series. Key dimensions labeled A through J are provided for each model capacity. A note indicates "2 inches Clearance Needed for T&P Release".

Nominal Gallon Capacity Model Number Dimension A Dimension B Dimension C Dimension D Dimension E Dimension F Dimension G Dimension H Dimension I Dimension J
40 PRO H40 T2RH310BM 62-5/16" 20-1/4" 47" 3-5/8" 39-5/8" 25-1/4" 20-1/2" 78-7/8" 22-3/8" 21-3/4"
50 PRO H50 T2RH310BM 61-3/4" 22-1/4" 47" 3-5/8" 39-5/8" 27-1/8" 22-1/2" 78-5/8" 24-3/8" 23-5/8"
65 PRO H65 T2RH310BM 64-3/16" 24-1/4" 49" 3-7/8" 42-3/8" 29-5/16" 24-5/8" 81-1/8" 26-1/2" 25-13/16"
80 PRO H80 T2RH310BM 74-3/16" 24-1/4" 59" 3-7/8" 52-3/8" 29-1/4" 24-5/8" 91" 26-1/2" 25-11/16"

Installation Guidelines

The following describes installation requirements based on room size and ducting configurations:

Heater: Not Ducted

Scenario 1: Large Room

Room size: Larger than 700 ft³ (e.g., 7' x 10' x 10').

Requirements: No additional ventilation needed.

Scenario 2: Smaller Room

Room size: Smaller than 700 ft³ (e.g., 7' x 10' x 10').

Requirements: Full louvered door OR two louvers (top and bottom). See below.

Scenario 3: Small Closet Installation

Requirements:

Diagram Note: Illustrates a 0.75 inch clearance under the door and a 12 inch maximum distance from the heater air exhaust to the door louver.

Heater: Ducted Installation

Scenario 4: Ducted with Inlet OR Outlet Duct

Room size: Any size room.

Requirements: Air gap under door equal to 18 square inches (0.75 inches clearance).

Scenario 5: Ducted with Inlet AND Outlet Duct

Room size: Any size room.

Requirements: No additional ventilation needed.

Hybrid Builder Accessories

Part Number Description Use For
SP20882 Earthquake Isolation Kit Installations in seismic regions
SP20883 Vibration Isolation Kit Installation on non-concrete floors
SP20884 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter
SP20885 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter
SP20886 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter
SP20887 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter
SP20888 8" Rheem Approved Damper Kit Exhaust only to the outside ducting configuration (no inlet duct)
SP20889 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting
SP20890 Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized
AP17829 Outlet Duct Adapter Allows for ducting to be connected to the unit
AP19134 Leak Sensor Automatic detection of internal and external leaks
AP21365 Inlet Duct Adapter Allows for ducting to be connected on the top inlet

Accessory Image Descriptions: The page displays images of various accessories including isolation kits, termination kits, damper kits, flexible and rigid duct kits, and duct adapters.

PDF preview unavailable. Download the PDF instead.

HP-310BM Rev4 GEN V Builder SS 1 Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)

Related Documents

Preview Rheem Hybrid Builder Residential Electric Water Heater | High Efficiency & Smart Technology
Explore the Rheem Hybrid Builder Residential Electric Water Heater, featuring high efficiency (3.50 UEF), integrated WiFi, ENERGY STAR certification, and smart technology for optimal energy savings. Ideal for builders.
Preview Rheem Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heater | Efficiency & Installation
Explore the Rheem Professional Prestige ProTerra Hybrid Electric Heat Pump Water Heater. Discover its high efficiency (UEF, ENERGY STAR), advanced features like LeakGuard™ and Wi-Fi integration, detailed specifications, and installation guidelines for optimal performance.
Preview Rheem ProTerra Plug-In Heat Pump Water Heater (120V): Efficient & Smart Residential Heating
Discover the Rheem ProTerra Plug-In Heat Pump Water Heater (120V Dedicated Circuit). Featuring high efficiency (3.0 UEF, ENERGY STAR), smart EcoNet Wi-Fi control, easy installation, and robust warranty for residential use. Available in 40 and 50-gallon capacities.
Preview Rheem ProTerra Plug-In Heat Pump Water Heater (120V Dedicated Circuit) - Specifications & Installation
Detailed specifications, features, and installation guidelines for the Rheem ProTerra Plug-In Heat Pump Water Heater (120V Dedicated Circuit). Learn about its efficiency, operation modes, smart integration, and accessory options.
Preview Rheem Professional Prestige ProTerra Hybrid Electric Water Heater | Efficiency, Specs, Installation
Discover the Rheem Professional Prestige ProTerra Hybrid Electric water heater. This guide details its high efficiency (up to 4.0 UEF), performance features, easy installation, integration capabilities (EcoNet WiFi), operation modes, warranty, and comprehensive specifications. Includes installation guidelines and available accessories.
Preview Rheem ENERGY STAR 5.0 Certified Water Heaters
Discover Rheem's water heaters certified under the new ENERGY STAR 5.0 performance requirements, effective April 18, 2023. This guide details certified Heat Pump, High Efficiency Gas (Tankless, Storage), and Boiler models, highlighting eligibility for federal tax credits.
Preview Rheem PERFORMANCE PLATINUM™ ProTerra® Hybrid Electric Heat Pump: Features, Specs, and Installation
Comprehensive guide to the Rheem PERFORMANCE PLATINUM™ ProTerra® Hybrid Electric Heat Pump with LeakGuard™. Details efficiency, performance, installation requirements, operation modes, specifications, and accessories. Features ENERGY STAR certification and advanced leak detection.
Preview Rheem Electric Residential Hybrid Water Heater: Use & Care and Installation Manual
Comprehensive guide for Rheem's Electric Residential Hybrid Water Heater, covering installation, operation, safety precautions, maintenance, and troubleshooting. Includes detailed instructions for installers and users.