PERFORMANCE PLATINUM™ ProTerra® Hybrid Electric Heat Pump with LeakGuard™
Product Overview
The Rheem PERFORMANCE PLATINUM™ ProTerra® Hybrid Electric Heat Pump with LeakGuard™ is presented as a highly efficient water heating solution.
Efficiency
- Features an Up to 4.07 UEF (Uniform Energy Factor) rating, reducing operating costs.
- ENERGY STAR® certified for energy efficiency.
Performance
- Delivers hot water faster than most standard electric water heaters.
- Offers a wide ambient operating range of 37-145° F, enabling more heat pump operation annually and designed to meet Northern Climate Spec (Tier 4).
- Provides quiet operation.
Easy Installation
- Universal top and side water connections simplify installation.
- Quick access to the electrical junction box.
- Duct-ready design for flexible installation.
- Easily replaces a standard electric water heater.
Integration
- Equipped with an LED Screen featuring a built-in water sensor alert with an audible alarm.
- Built-in Wi-Fi powered by EcoNet® allows users control via a free mobile app for customizable temperature, vacation settings, energy savings, and system monitoring from anywhere.
- Demand Response Ready with a built-in EcoPort™ (CTA-2045 Port).
- Includes the LeakGuard™ leak detection and prevention system with a factory-installed 360° leak detection cable and an auto shutoff valve, designed to limit leaks to no more than 20 ounces of water.
Operation Modes
- Energy Saver
- Heat Pump
- High Demand
- Electric
- Vacation/Away: Configurable for 2-28 days or placed on hold indefinitely.
Additional Features
- Premium grade anode rod extends tank life.
- Dip tube diffuser reduces sediment, improving efficiency and tank life.
- Features 3/4" NPT water inlet and outlet, and 3/4" condensate drain connections.
- Utilizes Incoloy stainless steel resistor elements.
- Includes dry-fire protection.
- Easy access, top-mounted washable air filter.
- 2" Non-CFC foam insulation for thermal efficiency.
- Enhanced flow brass drain valve.
- Temperature and pressure relief valve installed.
- Design certified to NSF/ANSI 372 (Lead Content).
Warranty
- 10-Year limited tank and parts warranty.
- Refer to the Residential Warranty Certificate for complete information.
Certifications and Compliance
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. They also meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code, and all state energy efficiency performance criteria.
- LEED Points = 3
- AHRI CERTIFIED
Key Specifications Summary
The PERFORMANCE PLATINUM Hybrid Electric Heat Pump is available in 40, 50, 65, and 80-Gallon capacities and operates on 208-240 Volt / 1 PH, requiring a 30 Amp breaker.
New Design Highlights
Features new top connections and a duct-ready design for enhanced installation flexibility.
Detailed Specifications
Fuel Type | Desc. | Nominal Gallon Cap. | Rated Gallon Cap. | Model Number | Electric Breaker Size | Uniform Energy Factor (UEF) | Element Wattage | Compressor Btu/H | First Hr. Rating G.P.H. | Recovery in G.P.H. 90° F Rise | Tank Height A | Diam. B | Ht. to Cold Inlet & Drain Valve | Ht. to Hot Outlet & T&P | Unit Wt. (LBS.) | Approx. Ship Wt. (LBS.) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electric | Tall | 40 | 36 | XE40T10HS45U1 | 30 | 3.83 | 4,500 | 4200 | 60 | 26 | 63" | 20-1/4" | 3-5/8" | 39-5/8" | 166 | 184 |
Electric | Tall | 50 | 45 | XE50T10HS45U1 | 30 | 3.88 | 4,500 | 4200 | 67 | 27 | 62" | 22-1/4" | 3-5/8" | 39-5/8" | 185 | 203 |
Electric | Tall | 65 | 59 | XE65T10HS45U1 | 30 | 4.05 | 4,500 | 4200 | 76.6 | 27 | 65" | 24-1/4" | 3-7/8" | 42-3/8" | 245 | 289 |
Electric | Tall | 80 | 72 | XE80T10HS45U1 | 30 | 4.07 | 4,500 | 4200 | 87 | 27 | 75" | 24-1/4" | 3-7/8" | 42-3/8" | 261 | 306 |
Dimensions (Shown in Inches)
DESCRIPTION | NOMINAL GALLON CAPACITY | MODEL NUMBER | A | B | C | D | E | F | G | H | I | J | K | L |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
40 | XE40T10HS45U1 | 62-5/16 | 20-1/4 | 47 | 3-5/8 | 39-5/8 | 23-3/8 | 20-1/2 | 78-7/8 | 20-1/4 | 23-1/4 | 64-15/16 | 67-7/16 | |
50 | XE50T10HS45U1 | 61-3/4 | 22-1/4 | 47 | 3-5/8 | 39-5/8 | 25-3/8 | 22-1/2 | 78-5/8 | 22-1/4 | 25-9/16 | 64-3/8 | 66-7/8 | |
65 | XE65T10HS45U1 | 64-3/16 | 24-1/4 | 49 | 3-7/8 | 42-3/8 | 27-1/2 | 24-5/8 | 81-1/8 | 24-1/4 | 27-3/8 | 66-13/16 | 69-5/16 | |
80 | XE80T10HS45U1 | 74-3/16 | 24-1/4 | 59 | 3-7/8 | 42-3/8 | 27-1/2 | 24-5/8 | 91 | 24-1/4 | 27-3/8 | 76-13/16 | 79-5/16 |
Note: A 2-inch clearance is needed for the Temperature and Pressure (T&P) relief valve release.
Installation Guidelines
Heater: Not Ducted
Room Size: Larger than 700 ft³ (e.g., 7' x 10' x 10'). Requirements: No additional ventilation needed.
Room Size: Smaller than 700 ft³ (e.g., 7' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom.
Room: Small Closet. Requirements: Air gap under door equal to 18 in² (0.75" clearance). Louver must be located the same height on door as the air exhaust on heater. Heater air exhaust must be positioned towards louver within one foot of door.
Heater: Ducted
With inlet OR outlet duct: Room size: Any size room. Requirements: Air gap under door equal to 18 in² (0.75" clearance).
With inlet AND outlet duct: Room size: Any size room. Requirements: No additional ventilation needed.
Note: Heat pump water heaters may operate in rooms less than 700 ft³ down to 450 ft³ but at reduced energy efficiency and performance. For optimal performance in small enclosures, a door or wall with a minimum of 2.3 sq ft of louvers is recommended for proper air changes.
Accessories List
PART NUMBER | DESCRIPTION | USE FOR |
---|---|---|
AP19134 | Leak Sensor | Automatic detection of internal and external leaks |
AS50618A | Shutoff Valve | Automatic shut off of water supply to unit |
SP20882 | Earthquake Isolation Kit | Installations in seismic regions |
SP20883 | Vibration Isolation Kit | Installation on non-concrete floors |
SP20884 | 8" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 8" diameter |
SP20885 | 7" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 7" diameter |
SP20886 | 6" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 6" diameter |
SP20887 | 5" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 5" diameter |
SP20888 | 8" Collar for Flex Venting | Exhaust only to the outside ducting configuration (no inlet duct) |
SP20889 | 25' Flexible 8" Diameter Duct Kit | For up to 25' of ducting |
SP20890 | 8" Rigid Elbow Duct Kit | Installation in tight places where space needs to be minimized |
Visual representations of accessories include: Leak Sensor, Shutoff Valve, Earthquake Isolation Kit, Vibration Isolation Kit, 8" Diameter UL Certified Termination Kit, 7" Diameter UL Certified Termination Kit, 6" Diameter UL Certified Termination Kit, 5" Diameter UL Certified Termination Kit, 8" Collar for Flex Venting, 25' Flexible 8" Diameter Duct Kit, 8" Rigid Elbow Duct Kit.
Company Information
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 • Roswell, Georgia 30076
Website: www.rheem.com