Rheem® Hybrid Builder Residential Electric Water Heater
Designed for Builders to Maximize Energy Design Rating/HERS Rating
Product Highlights
- 3.50 UEF
- Meets NEEA Tier 3 Requirements
- Integrated WiFi ?
- California Title 24 Compliant (JA13 Ready)
- Quiet Operation ?
- Design certified to NSF/ANSI 372 (lead control)
- 10 Year Limited Warranty ?️
The unit qualifies for national utility rebates and is ENERGY STAR certified. It also contributes 3 LEED Points.
Features & Benefits
- High Efficiency: Meets ENERGY STAR® requirements, increasing property value for consumers.
- Easy Installation: Easily ducted for installation in confined spaces with minimal make-up air. Features easy access to side water connections and top electrical junction box, requiring zero clearance at the back or sides. Includes 3/4" NPT water inlet & outlet and 3/4" condensate drain connections. Equipped with dry fire protection ✔️.
- Available EcoNet® Smart Technology: Provides integrated WiFi ? for energy usage reporting and energy saving scheduling.
The unit comes with the Temperature and Pressure (T&P) relief valve installed.
Hybrid Electric Builder Select Models
Available in 40, 50, 65, and 80-Gallon Capacities. Operates on 208-240 Volt / 1 PH / 24 Amps.
Specifications
Nominal Gallon Capacity | Rated Gallon Capacity | Model Number | Model Variant | Electric Breaker Size | Uniform Energy Factor (UEF) | Estimated Yearly Energy Cost | Compressor BTU/H | First Hour Recovery G.P.H. | Recovery G.P.H. 90° F Rise | Unit Wt. (LBS) | Approx. Ship Wt. (LBS.) |
---|---|---|---|---|---|---|---|---|---|---|---|
40 | 36 | PRO H40 T2RH310BM | 700461 | 30 | 3.50 | $111 | 4200 | 60 | 26 | 156 | 177 |
50 | 45 | PRO H50 T2RH310BM | 700455 | 30 | 3.50 | $111 | 4200 | 67 | 26 | 172 | 193 |
65 | 59 | PRO H65 T2RH310BM | 700456 | 30 | 3.50 | $111 | 4200 | 75 | 26 | 225 | 262 |
80 | 72 | PRO H80 T2RH310BM | 700457 | 30 | 3.50 | $170 | 4200 | 87 | 26 | 244 | 281 |
Estimated energy cost based on a national average electricity cost of $0.12/kWh. Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.
1See Residential Warranty Certificate for complete information. 2WiFi broadband internet connection required. 3Consult your tax advisor for details on eligibility requirements for any available tax credits. Rebates vary by state.
Dimensions
Diagrams show top and side views of the water heater with key dimensions labeled A through J.
Nominal Gallon Capacity | Model Number | A | B | C | D | E | F | G | H | I | J |
---|---|---|---|---|---|---|---|---|---|---|---|
40 | PRO H40 T2RH310BM | 62-5/16 | 20-1/4 | 47 | 3-5/8 | 39-5/8 | 25-1/4 | 20-1/2 | 78-7/8 | 22-3/8 | 21-3/4 |
50 | PRO H50 T2RH310BM | 61-3/4 | 22-1/4 | 47 | 3-5/8 | 39-5/8 | 27-1/8 | 22-1/2 | 78-5/8 | 24-3/8 | 23-5/8 |
65 | PRO H65 T2RH310BM | 64-3/16 | 24-1/4 | 49 | 3-7/8 | 42-3/8 | 29-5/16 | 24-5/8 | 81-1/8 | 26-1/2 | 25-13/16 |
80 | PRO H80 T2RH310BM | 74-3/16 | 24-1/4 | 59 | 3-7/8 | 52-3/8 | 29-1/4 | 24-5/8 | 91 | 26-1/2 | 25-11/16 |
Note: 2" Clearance Needed for T&P Release.
Installation & Ventilation Requirements
Heater: Not Ducted
- Room size: Larger than 700 ft³ (e.g., 7' x 10' x 10'). Requirements: No additional ventilation needed.
- Room size: Smaller than 700 ft³ (e.g., 7' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom.
- Room: Small Closet. Requirements: Air gap under door equal to 18 in² (0.75" clearance) ?. Louver must be located the same height on door as the air exhaust ? on heater. Heater air exhaust must be positioned towards louver within one foot of door.
Heater: Ducted with inlet OR outlet duct
- Room size: Any size room. Requirements: Air gap under door equal to 18 in² (0.75" clearance) ?.
Heater: Ducted with inlet AND outlet duct
- Room size: Any size room. Requirements: No additional ventilation needed.
Diagrams illustrate these different installation configurations.
Hybrid Builder Accessories
Images show various accessory kits available for the water heater.
Part Number | Description | Use For |
---|---|---|
SP20882 | Earthquake Isolation Kit | Installations in seismic regions |
SP20883 | Vibration Isolation Kit | Installation on non-concrete floors |
SP20884 | 8" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 8" diameter |
SP20885 | 7" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 7" diameter |
SP20886 | 6" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 6" diameter |
SP20887 | 5" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 5" diameter |
SP20888 | 8" Rheem Approved Damper Kit | Exhaust only to the outside ducting configuration (no inlet duct) |
SP20889 | 25' Flexible 8" Diameter Duct Kit | For up to 25' of ducting |
SP20890 | Rigid Elbow Duct Kit | Installation in tight places where space needs to be minimized |
AP17829 | Outlet Duct Adapter | Allows for ducting to be connected to the unit |
AP19134 | Leak Sensor ? | Automatic detection of internal and external leaks |
AP21365 | Inlet Duct Adapter | Allows for ducting to be connected on the top inlet |