Product Overview
The Rheem ProTerra Plug-In Heat Pump Water Heater (120V Dedicated Circuit) offers advanced efficiency and smart features for residential comfort.
Efficiency
- Up to 3.0 UEF reduces operating cost.
- ENERGY STAR® rated.
Performance
- Ambient operating range: 37-145°F, widest in class designed to meet Northern Climate Spec (Tier 2).
Easy Installation
- Easy access side connections.
- Factory installed plug-in power cord, direct plug-in.
- Easily replaces a standard gas water heater.
Integration
- LED display allows easy control and system monitoring with alerts and audible alarms [note 1].
- Integrated EcoNet® WiFi-connected [note 2] technology and free mobile app gives users control over water heater, allowing for customizable temperature, vacation settings, energy savings and system monitoring at home or away.
- LeakGuard™ and LeakSense™ Ready: Easily add leak detection and prevention with leak sensor and shutoff valve upgrade kit.
- Demand Response Ready: Built-in EcoPort™ (CTA-2045 Port) allows easy connection to Utility programs.
Operation Modes
- Heat Pump
- Vacation/Away: 2-28 days (or placed on hold indefinitely).
Additional Features
- Premium grade anode rod with resistor extends the life of the tank.
- 3/4" NPT water inlet and outlet; 3/4" condensate drain connections.
- Easy access, top mounted washable air filters.
- 2" Non-CFC foam insulation.
- Enhanced flow brass drain valve.
- Temperature and pressure relief valve installed.
- Design certified to NSF/ANSI 372 (Lead Content).
Warranty
- 10-Year limited tank and parts warranty. (See Residential Warranty Certificate for complete information).
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.
These products meet a stringent set of internally defined sustainability standards.
LEED Points = 3
Specifications
Model Capacities: 40 and 50 Gallons
Electrical: 120 Volt / 1 PH Electric, 15 Amp Time Delay Breaker
Nominal Gallon Capacity | Rated Gallon Capacity | Model Number | Uniform Energy Factor (UEF) | Compressor BTU/H | Sound Level (dBA) | Recovery in G.P.H. (60°F Rise) | Height (A) | Diameter (B) | Unit Weight (LBS) | Approx. Ship Weight (LBS.) |
---|---|---|---|---|---|---|---|---|---|---|
40 | 37 | PROPH40 TO RH120 (700948) | 3.0 | 12,000 | 55 | 28 | 65-5/8" | 20-1/4" | 200 | 242 |
50 | 46 | PROPH50 TO RH120 (700949) | 3.0 | 12,000 | 55 | 29 | 65" | 22-1/4" | 210 | 252 |
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. All units have integrated WiFi control board.
Heat Up Time Data
Heat Up Time To 120°F vs Initial Tank Water Temp. @ Ambient Air Temperature 75°F
Graph Description: A line graph showing the relationship between Inlet Tank Water Temperature (°F) on the x-axis (ranging from 40 to 100) and Heat Up Time (min) on the y-axis (ranging from 0 to 100). Multiple lines indicate different initial tank temperatures.
Initial Tank Temp (°F) | Final Tank Temp (°F) | Heat Up Time (min) |
---|---|---|
40 | 120 | 91.1 |
50 | 120 | 83.7 |
58 | 120 | 77.4 |
70 | 120 | 67.1 |
87 | 120 | 51 |
100 | 120 | 37.2 |
Dimensions
Diagram Description: Front and side views of the water heater showing dimensions labeled A through I. A top view shows dimensions B, F, and G. A note indicates "2" Clearance Needed for T&P Release". Text "Insulate ducting to reduce condensation." is present.
Nominal Gallon Capacity | Model Number | A (Height) | B (Diameter) | C | D | E | F | G | H | I |
---|---|---|---|---|---|---|---|---|---|---|
40 | PROPH40 | 65-5/8" | 20-1/4" | 47-13/16" | 3-5/8" | 39-5/8" | 23-3/8" | 20-1/2" | 81" | 21-3/4" |
50 | PROPH50 | 65" | 22-1/4" | 47-1/4" | 3-5/8" | 39-5/8" | 25-3/8" | 22-1/2" | 80-3/8" | 21-3/4" |
Installation Guidelines for Optimal Efficiency
All volume is cubic feet.
Installation Scenarios
- Not Ducted (Large Room): Room size larger than 1200 ft³ (e.g., 12' x 10' x 10'). Requirements: No additional ventilation needed.
- Not Ducted (Medium Room): Room size 400 ft³ (e.g., 5' x 8' x 10') to 1200 ft³ (e.g., 12' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom. Minimum 2.9 ft² louver area.
- Ducted with Outlet Duct: Room size smaller than 400 ft³ (e.g., a closet). Requirements: Full louvered door. Minimum 3.25 ft² louver area. Insulate ducting to reduce condensation.
Insufficient air circulation may result in an ambient air temperature drop of more than 15°F (8°C) and inefficient operation. Refer to the room size volume illustrations to determine optimal installation and if exhaust should be ducted. Installation Space Volume is the unoccupied, free air space required for optimal operation. Additional objects occupying the space reduce total space volume.
Location Recommendation
For optimal operation, installation in the gray US map zone is recommended. When installing outside of the gray zone, consult your local plumbing contractor.
Minimum Clearances (Without Ducting)
REAR | SIDES | TOP |
---|---|---|
0" | 3" | 9" |
Average Ambient Air Temperature in January
Consideration should be given to ambient air temperatures below 37°F and above 37°F for optimal performance.
ProTerra Plug-in Heat Pump Accessories List
Part Number | Description | Use For |
---|---|---|
AP18944D | Leak Sensor | Automatic detection of internal and external leaks. |
AP20180 | Shutoff Valve | Automatic shut off of water supply to unit. |
AP21851 | Outlet Duct Adapter | Allows for ducting to be connected to the unit. |
SP20882 | Earthquake Isolation Kit | Installations in seismic regions. |
SP20883 | Vibration Isolation Kit | Installation on non-concrete floors. |
SP20884 | 8" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 8" diameter. |
SP20885 | 7" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 7" diameter. |
SP20886 | 6" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 6" diameter. |
SP20887 | 5" Diameter UL Certified Termination Kit | Termination to the outside or to the attic with 5" diameter. |
SP20888 | 8" Pro Approved Damper Kit | Exhaust only to the outside ducting configuration (no inlet duct). |
SP21189 | 25' Flexible 8" Diameter Duct Kit | For up to 25' of ducting. |
SP21111 | Leak Sensor & Shutoff Valve Kit | Upgrade models to protect home from water damage with leak detection and auto shutoff valve. |
Upgrade Kit Note: The UPGRADE KIT (for ProTerra models without LeakGuard only) adds a leak detector and shutoff valve to protect from water damage.