Rinnai Gas Fire Ordering Guide

Models Covered: 650 & 750, 950 & 1250, SS850, and LS Series

Effective September 2024

Rinnai 650 & 750 Series

Step 1. Select Model and Gas Type

ModelGas TypeCodeDimensionsOutput - kWInput - mj/h
Rinnai 650 [includes remote]Natural Gas650ENGN654H x 640W mm523
LPG650ENGL
Rinnai 750 [includes remote]Natural Gas750ENGN654H x 750W mm627
LPG750ENGL

Image of Rinnai 650 Gas Fire

Image of Rinnai 750 Gas Fire

Step 2. Select Fascia Option and Colour

FASCIA DESCRIPTION650 CODE750 CODE
3 Sided - Black650F31P750F31P
3 Sided - Titanium Grey650F32750F32
4 Sided - Black650F41P750F41P
4 Sided - Titanium Grey650F42750F42
3 Sided - Masonry Black XL (660 H x 825 W mm)-750F41XLP

A 3-sided frame is suitable for masonry applications or where the appliance sits directly at floor level.

A 4-sided frame is suitable for timber frame applications where the appliance is raised off the floor.

The XL masonry frame is suitable for masonry applications where the fireplace cavity requires a larger frame; this is available in 3-sided and black only.

Step 3. Select Burn Media Option

ModelGas TypeCode
Rinnai 650Glow Stones650M1
Natural Wood Log Set650M2
Rinnai 750Glow Stones750M1
Natural Wood Log Set750M2

Image of Glow Stones burn media

Image of Natural Wood Log Set burn media

Step 4. Extras

DescriptionSuitsCODE
Zero clearance frame kit - used for ALL timber frame applications650 & 750 (Common part)650750ZCK
In-fill panels - for oversize masonry chimney cavities. Black only650-700mm wide x 700 high
750-800mm wide x 700 high
650IFP
750IFP
Gas fire Wi-Fi module650 & 750GFFWIFIMOD
Telescopic flue275 - 375mm Adjustable Flue LengthRDV911
Weatherproof box - for external wall applications650 & 750 (Common part)650750WPB

Diagram illustrating zero clearance frame kit installation

Diagram of weatherproof box for external wall applications

Image of Gas Fire Wi-Fi Module interface on a smartphone

Step 5. Select Flueing Configuration & Components

Masonry Chimney

UnitDescriptionCode
Total flue kit includes: aluminium co-linear roof cowl DV, chimney plate, intake flexi, exhaust flexi, two of 75mm flue clamps and two of 100mm flue clamps 5.5m length. Suitable for masonry applications.850FLEX
Flue Kit 2.5m - Extension Kit Co-Linear Flexi. Optional - if more flue length required (masonry installation only).850CLFLEX

Masonry Horizontal

UnitDescriptionCode
Flexible pipes and co-linear to co-axial adaptor. Stretches out to 1.2m.RDVFA
Horizontal flue spigotRDVHFS
Horizontal terminalRDV984

Ideal for applications where the flue cannot terminate vertically. Masonry only - this flue configuration is not suitable for combustible applications.

Vertical Flue (Timber frame applications)

UnitDescriptionCode
Co-linear to co-axial adaptor - includes 2 x flexi pipes, plate and transition piece. Stretches out to 1.2m.RDVFA
Select length co-axial pipeSee price list
Vertical roof cowlRDV991
Zero clearance kit650750ZCK

Horizontal Flue (Timber frame applications)

UnitDescriptionCode
Co-linear to co-axial adaptor - includes 2 x flexi pipes, plate and transition piece. Stretches out to 1.2m.RDVFA
90 degree elbowRDV990G
Select length co-axial pipeSee price list
Horizontal wall capRDV984
Zero clearance kit650750ZCK

Weatherproof Box

UnitDescriptionCode
Co-linear to co-axial adaptor - includes 2 x flexi pipes, plate and transition piece. Stretches out to 1.2m.RDVFA
Horizontal flue spigotRDVHFS
Horizontal wall capRDV984
Weatherproof box650750WPB
Zero clearance kit650750ZCK

Additional Flue Components

UnitDescriptionCode
Pipe length 48 inch - (1200mm)RDV902
Pipe length 36 inch - (900mm)RDV903
Pipe length 24 inch - (600mm)RDV904
Pipe length 12 inch - (300mm)RDV906
Pipe length 9 inch - (230mm)RDV907
Adjustable Pipe Length 11 - 14 inch - (275 - 375mm)RDV9117
45° ElbowRDV945G
90° ElbowRDV990G
High Wind Terminal Cap (Vertical Cowl)RDV991

Diagram of High wind terminal cap (vertical cowl)

Diagram of Horizontal terminal cap with dimensions

Rinnai SS850 Series

Step 1. Select Gas Type

ModelGas TypeCodeDimensionsOutput - kWInput - mj/h
SS850 Built-In Co Axial in TimberNatural GasSS850ICAN660 H x 865 W mm6.630
LPGSS850ICAL
SS850 Built-In Co-Linear in MasonryNatural GasSS850ICLN660 H x 865 W mm6.630
LPGSS850ICLL
SS850 FreestandingNatural GasSS850FCAN660 H x 865 W mm6.630
LPGSS850FCAL

Image of Rinnai SS850 Built-In Gas Fire

Image of Rinnai SS850 Cabinet Gas Fire

Image of Rinnai SS850FS Freestanding Gas Fire

Step 2. Select Fascia Option and Colour

ModelAccessoryCode
SS850 Built-In Co Axial in TimberFascia Classic SS850 BronzeSS850CFB
Infill Panel SS850 BlackSS850IFP
SS850 Built-In Co Linear in MasonryFascia Classic SS850 BronzeSS850CFB
SS850 Cabinet BaseSS850FSBC
SS850 FreestandingSS850 Plinth BaseSS850FSBP

Image of Black fascia option

Image of Bronze fascia option

Image of Rinnai SS850 Cabinet Gas Fire

Image of Rinnai SS850FS Freestanding Gas Fire

Step 3. Extras - Optional

ModelGas TypeCode
Rinnai SS850Wi-Fi KitGFFWIFIMOD

Image of Gas Fire Wi-Fi Module interface on a smartphone

Step 4. Flue Kit Selection

ModelSelected Flue KitsCode
SS850 Built-In Co Axial in TimberFlue Kit DV - 3.6m Vertical co-axial (Galvanised)RDVSV
SS850 Built-In Co Linear in MasonryFlue Kit Flexi - 5.5m Co-linear850FLEX
Flue Kit Flexi - 2.5m Extension co-linear850CLFLEX
SS850 FreestandingFlue Kit DV - 3.6m Vertical co-axial (Black)RDVSVB

Image of Flue Kit DV 3.6m (Galvanised)

Image of Flue Kit Flexi 5.5m

Image of Flue Kit Flexi 2.5m

Image of Flue Kit DV 3.6m

Step 5. Select Mandatory Flue Components

ModelSelected Flue KitsCode
SS850 Built-in co-Axial in timberFlue support for flues and elbows
High wind vertical cowl protection kit
RDV951
RDB992
SS850 Built-in co-linear in masonryHigh wind vertical cowl protection kitRDB992
SS850 FreestandingFlue support for flues and elbows
High wind vertical cowl protection kit
RDV951
RDB992

Diagram of Flue support RDV951

Diagram of Flue support RDB992

Step 6. Flueing Components

Rinnai SS850 Built-in co-axial

UnitDescriptionCode
275 - 375mm Adjustable flue lengthRDV911
230mm Flue lengthRDV907
300mm Flue lengthRDV906
600mm Flue lengthRDV904
900mm Flue lengthRDV903
1200mm Flue lengthRDV902
45 Degree elbowRDV945G
45 Degree elbow x 2 - GALRDV945G2
90 Degree elbowRDV990G
Wall strap DVRDV954
Coaxial vertical flue cowlRDV991

Diagram showing dimensions for flue components

Diagram of 275-375mm Adj. Flue Length

Diagram of 230-1200mm Flue Length

Diagram of 45 Degree Elbow

Diagram of 90 Degree Elbow

Diagram of Wall Strap DV

Diagram of Coaxial Vertical Flue Cowl

Rinnai SS850 Freestanding

UnitDescriptionCode
230mm Flue length - BlackRDV907B
300mm Flue length - BlackRDV906B
600mm Flue length - BlackRDV904B
900mm Flue length - BlackRDV903B
1200mm Flue length - BlackRDV902B
360mm Flue extension - BlackRDV911B
45 Degree elbow x 2 - BlackRDV945B
90 Degree elbow - BlackRDV990B
Flue DV ceiling plate 90 DegreeRDVCP90
Flue DV ceiling plate 45 DegreeRDVCP45

Diagram of 230-1200mm Flue Length

Diagram of 360mm Flue Extension

Diagram of 45 Degree Elbow

Diagram of 90 Degree Elbow

Diagram of Flue DV Ceiling Plate 90 Degree

Diagram of Flue DV Ceiling Plate 45 Degree

Rinnai 950 & 1250 Series

Product Overview

ModelDimensionsOutput - kWInput - mj/h
Rinnai 950 [includes remote]620H x 1020Wmm8.034
Rinnai 1250 [includes remote]620H x 1320Wmm8.434

Image of Rinnai 950 Gas Fire

Image of Rinnai 1250 Gas Fire

Step 1. Select Engine, Fascia, Burn Media & Gas Type

Rinnai 950 Series

ModelGas TypeCode
Black 952 Logset Engine
Black fascia / logset media
Natural GasK952BN
LPGK952BL
Stainless 952 Logset Engine
SS on black fascia / Logset media
Natural GasK952SN
LPGK952SL
Black 952 Ceramic Stones Engine
Black fascia / Ceramic Stones Media
Natural GasK952BCN
LPGK952BCL
Stainless 952 Ceramic Stones Engine
SS on Black fascia / Ceramic Stones Media
Natural GasK952SCN
LPGK952SCL

Rinnai 1250 Series

ModelGas TypeCode
Black 1253 Logset Engine
Black fascia / Logset media
Natural GasK1253BN
LPGK1253BL
Stainless 1253 Logset Engine
SS on black fascia / Logset media
Natural GasK1253SN
LPGK1253SL
Black 1253 Ceramic Stones Engine
Black fascia / Ceramic Stones Media
Natural GasK1253BCN
LPGK1253BCL
Stainless 1253 Ceramic Stones Engine
SS on Black fascia / Ceramic Stones Media
Natural GasK1253SCN
LPGK1253SCL

Step 2. Extras

DescriptionCODE
Weatherproof Box Kit 950950WPB
Weatherproof Box Kit 12501250WPB
Gas Fire Wi-Fi Module* 950/1250GFFWIFIMOD
Reflective side panels 12501250REF1

Diagram of Weatherproof Box - External view.

Image of Gas Fire Wi-Fi Module interface on a smartphone

Step 3. Flue Installation Configuration

Direct / Extended

DescriptionComponentCODE
Option A [Direct]Direct Flue Kit Rinnai FlamefiresASPDFK
Option B [Direct Extended]Direct Flue Kit
# Co-Ax Pipe 900mm [Optional]
ASPDFK
ESPIPE900

External Wall

DescriptionComponentCODE
Option A [Vertical Termination]Direct Flue Kit Rinnai Flamefires
# Co-Ax Pipe 900mm
45° Bend x 2
Condensate Trap
Roof Cowl
ASPDFK
ESPIPE900
ESBEND
ESCONDK
ESROOFCOWL
Option B [Wall Termination]Direct Flue Kit Rinnai Flamefires
# Co-Ax Pipe 900mm
45° Bend x 2
Condensate Trap
Wall Terminal Kit
ASPDFK
ESPIPE900
ESBEND
ESCONDK
ESWTKIT

Diagram illustrating external wall flue installation configuration (Vertical Termination)

Diagram illustrating external wall flue installation configuration (Wall Termination)

Internal Wall

DescriptionComponentCODE
Option A [Direct]##Flue Adaption Kit Flamefires
# Co-Ax Pipe 900mm
Roof Cowl
ASPKIT03
ESPIPE900
ESROOFCOWL
Option B [Offset]##Flue Adaption Kit Flamefires
# Co-Ax Pipe 900mm
45° Bend x 2
Roof Cowl
ASPKIT03
ESPIPE900
ESBEND
ESROOFCOWL
Option C [Offset] GLFFKITIW Kit [Same configuration as option B, but with longer flue length]##Flue Adaption Kit x 1 pce
Co-Ax Pipe 900mm x 3 pces
45° Bend x 2 pces
Roof Cowl x 1 pce
ASPKIT03
ESPIPE900
ESBEND
ESROOFCOWL

#Order lengths as required. ##Includes Condensate Trap [ESCONDK]

Diagram illustrating internal wall flue installation configuration (Option A)

Diagram illustrating internal wall flue installation configuration (Option B)

Diagram illustrating internal wall flue installation configuration (Option C)

Rinnai 950 & 1250 Flue Components

Diagram and description of ASPDFK (Direct Flue Kit for Rinnai Flamefires)

Diagram and description of ASPKIT03 (Flue Adaption Kit for Rinnai Flamefires)

Diagram and description of GLFFKITIW (Extended Flue Adaption Kit for Rinnai Flamefires)

Diagram and description of ESPIPE

Diagram and description of ESROOFCOWL

Diagram and description of ESBEND

Sideways Flue Installation Configuration

DescriptionComponentCODE
Direct##Flue Adaption Kit Flamefires
# Co-Ax Pipe 900mm
Terminal Kit
ASPKIT03
ESPIPE900
ESWTERM

Under Floor Flue Installation Configuration

DescriptionComponentCODE
Direct##Flue Adaption Kit Flamefires
# Co-Ax Pipe 900mm
45° Bend x 2 pces
Terminal Kit
ASPKIT03
ESPIPE900
ESBEND
ESWTERM

IMPORTANT: A maximum flue length of 8.5 metres is permissible provided there are no bends. Each 90° bend is equivalent to 1 metre of flue length. Therefore, the total flue length may be up to 6.5 metres with 2 x 90° bends. The ASPKIT03 Flue Adaptor contains one bend and this is counted as 1 x 90° bends.

#Order lengths as required. ##Includes Condensate Trap [ESCONDK]

LS Series Selection Guide

Step 1. Select Engine Type

UnitDescriptionCode
LS 800F + Log SetLS 800F FlameTech® single sided NG
LS 800F FlameTech® single sided LPG
LS 800F FlameTech® double sided NG
LS 800F FlameTech® double sided LPG
LS800SFN
LS800SFL
LS800DFN
LS800DFL
LS 1000F + Log SetLS 1000F Flametech single sided NG
LS 1000F Flametech single sided LPG
LS 1000F Flametech double sided NG
LS 1000F Flametech double sided LPG
LS1000SFN
LS1000SFL
LS1000DFN
LS1000DFL
LS 1000 + Log SetLS 1000 single sided NG + Log Set
LS 1000 single sided LPG + Log Set
LS 1000 double sided NG + Log Set
LS 1000 double sided LPG + Log Set
KLS1000SN1
KLS1000SL1
KLS1000DN1
KLS1000DL1
LS 1000 + Burn MediaLS 1000 single sided NG + Burn Media
LS 1000 single sided LPG + Burn Media
LS 1000 double sided NG + Burn Media
LS 1000 double sided LPG + Burn Media
KLS1000SN2
KLS1000SL2
KLS1000DN2
KLS1000DL2
LS 1500 + Log SetLS 1500 single sided NG + Log Set
LS 1500 single sided LPG + Log Set
LS 1500 double sided NG + Log Set
LS 1500 double sided LPG + Log Set
KLS1500SN1
KLS1500SL1
KLS1500DN1
KLS1500DL1
LS 1500 + Burn MediaLS 1500 single sided NG + Burn Media
LS 1500 single sided LPG + Burn Media
LS 1500 double sided NG + Burn Media
LS 1500 double sided LPG + Burn Media
KLS1500SN2
KLS1500SL2
KLS1500DN2
KLS1500DL2

Image of LS 800F gas fire

Image of LS 1000F and LS 1000 gas fire

Image of LS 1500 gas fire

Step 2. Select Flue Kits and Components

UnitDescriptionCode
LS SeriesDirect Flue Kit
LS Flue Adaptor Kit
LS Extended Flue Adaptor Kit
LS Flue Transition Extension Kit
Flue pipe 900mm
Vertical flue terminal
Bends (2 x 45°)
Universal plate
Wall terminal kit
Flue guard
Wall terminal kit 2
LSFDFK01
LSFKIT01
LSFKIT02
LSEXTKIT01
ESPIPE900
ESROOFCOWL
ESBEND
ESPLATE
ESWTERM
ESWFG
ESWTKIT2

Diagram of Direct Flue Kit LSFDFK01

Diagram of LS Flue Adaptor Kit LSFKIT01

Diagram of LS Extended Flue Adaptor Kit LSFKIT02 (Total length: 4m)

Diagram of LS Flue Transition Extension Kit LSEXTKIT01

Diagram of Flue pipe 900mm

Diagram of Vertical Flue Terminal

Diagram of Bends (2 x 45°)

Diagram of Universal plate

Diagram of External wall plate

Diagram of Flue guard

Diagram of Wall terminal kit 2

Step 3. Select Extras - Optional

UnitDescriptionCode
LS 800FPeninsula pack LS800 L
LS800 wide trim 50mm
LS800 gas fire window kit
LS800PENPCKL2
LS800WT50
LS800DFWKIT
LS 1000F and LS 1000Peninsula pack LS1000/LS1500
LS1000 wide trim 50mm
LS1000 gas fire window kit
LS10001500PENPCKL2
LS1000WT50
LS1000DWKIT
LS 1500Peninsula pack LS1000/LS1500
LS1500 wide trim 50mm
LS1500 gas fire window kit
LS10001500PENPCKL2
LS1500WT50
LS1500DWKIT

Diagram of Peninsula pack accessory

Diagram of Wide trim accessory

Diagram of Window kit accessory

Models: 650ENGN, 650ENGL, 750ENGN, 750ENGL, 650ENGN Gas Fire, 650ENGN, Gas Fire, Fire

File Info : application/pdf, 20 Pages, 3.31MB

PDF preview unavailable. Download the PDF instead.

RA108.09.24-Rinnai-Gas-Fire-Ordering-Guide WEB Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)

Related Documents

Preview Rinnai Gas Fires: Contemporary Heating & Ambiance
Discover Rinnai's collection of contemporary Gas Fires, blending modern design with efficient heating and captivating ambiance. Explore models like the 650, 750, 950, 1250, Sapphire, and Slimfire, featuring advanced technology, Wi-Fi control, and flexible installation options for any home.
Preview Rinnai Air Conditioning: Extended 7-Year Warranty Announcement
Rinnai Australia announces an extended 7-year warranty for its air conditioning products, effective April 1st, 2025. This document details the warranty coverage, benefits for homeowners and installers, and Rinnai's commitment to quality and customer peace of mind.
Preview Rinnai SS850 Gas Fireplace Installation Manual
Comprehensive installation guide for the Rinnai SS850 Inbuilt Gas Fireplace, covering safety, requirements, flueing, connections, and commissioning.
Preview Rinnai SE Series Infrared Radiant Gas Heater Specifications | Commercial & Industrial
Detailed HVAC guideline specifications for Rinnai SE Series Packaged High Intensity Infrared Radiant Gas Heaters, covering models RSE1S35 and RSE1S50 for commercial and industrial applications. Includes system description, quality assurance, product details, performance, and accessories.
Preview Rinnai ES Electric Fire Series Operation and Installation Guide
Comprehensive guide for the Rinnai ES Electric Fire Series, covering operation, installation, safety, and warranty information for models ES750, ES1000, ES1300, ES1500, ES1800, and ES2200.
Preview Rinnai NB-Series Quick Start Guide: Setup and Configuration
A concise guide to setting the gas type, location, and labeling your Rinnai NB-Series water heater. Includes instructions for initial setup and changing settings.
Preview Rinnai Tankless Water Heater Outdoor Conversion Manual
This Rinnai manual provides comprehensive instructions for converting Rinnai indoor tankless water heaters to outdoor installations. It covers safety guidelines, outdoor location selection, power supply connection, outdoor vent cap installation, and parameter adjustments for optimal performance. Includes model compatibility and clearance requirements.
Preview Rinnai Pro Series Wi-Fi User Guide: Connecting and Controlling Your Air Conditioner
A comprehensive user guide for the Rinnai Pro Series Wi-Fi enabled air conditioners. Learn how to set up, register, and control your unit remotely using the NetHome Plus app.