Berzelia Street CL 2070
Installation Manual
Please read this instruction manual before installation and keep it for future reference.
Intended Use
The luminaire is designed for standard outdoor use and in coastal areas. It is not suitable for corrosive atmospheres such as those found in tunnels or harbours.
Safety Instructions
- Installation and maintenance should only be performed by qualified electricians with expert knowledge.
- Never work on the luminaire while it is energized. Caution: Risk of fatal injury!
- Ensure the luminaire is undamaged before installation and operation.
- The manufacturer is not liable for damages resulting from incorrect, unauthorized use, or failure to follow these instructions.
- Work on the luminaire, including installation, maintenance, servicing, and troubleshooting, must be carried out by an authorized electrician.
5-Year Warranty Policy
Aura Light provides a 5-year warranty covering manufacturing and material defects for products manufactured and/or sold by Aura Light. This warranty is subject to the product information available on www.auralight.com or in printed materials from Aura Light.
Technical Features
Feature | Specification |
---|---|
Voltage | 220-240V~ |
Frequency | 50/60 Hz |
Insulation Class | Class I / Class II |
Weight | 3.5 kg |
Ambient Temperature (ta) | 50 °C |
Power Factor | >0.95 |
Projection Area | 0.10 m² |
Glass Type | Tempered Glass |
Product Specifications Table
The Berzelia Street CL 2070 is available in various configurations:
Series/Model | LED Wattage (W) | Max Power (W) | Supply Current (A) | Class I | Class II |
---|---|---|---|---|---|
Berzelia Street CL 2070 | 16 | 16 | 0.07 | X | X |
24 | 24 | 0.11 | X | X | |
35 | 35 | 0.16 | X | X | |
40 | 40 | 0.18 | X | X | |
50 | 50 | 0.23 | X | X | |
60 | 60 | 0.27 | X | X | |
75 | 75 | 0.34 | X | - |
Installation and Mounting
- The luminaire is suitable for outdoor use (IP66 rated).
- If the external flexible cable or cord is damaged, it must be replaced by the manufacturer or their authorized service agent to prevent hazards.
- Installation requires a qualified person as a terminal block is not included.
- The integrated light source can only be replaced by the manufacturer, their service agent, or a similarly qualified person.
- For optimal performance, recommended pole heights range from 4 to 8 meters, ensuring the luminaire is installed outside of arm's reach.
Mounting Options and Adjustments:
The adjustable mounting module allows the luminaire to be fixed via side entry or post-up entry, offering 16 different angle adjustments.
A torque of 10 Nm should be applied to the mounting module bolt for secure fastening.
For pole mounting, use size 4 stainless steel allen keys or size 13 bolt keys. The luminaire itself should be fixed to the pole or console using a size 4 key.
Spigot Dimensions: The spigot for both post-up and side entry has a diameter (Ø) of 42-60mm and an entry dimension (la) of 100mm to the mounting module.
Electrical Connection:
The luminaire features an easy connect system for electrical connections.
Wiring:
- CLASS I: Brown wire for Line, Blue wire for Neutral, Green/Yellow wire for Earth.
- CLASS II: Brown wire for Line, Blue wire for Neutral.
Diagrammatic Information Summary
Luminaire Dimensions: The luminaire measures approximately 610 mm in length, 160 mm in width, and 85.2 mm in height.
Mounting Angle Adjustments: The mounting module supports angle adjustments of ±5°, ±10°, and ±15° for both side entry (S/Y) and post-up entry (P/A) configurations.
Recommended Pole Heights: The document illustrates recommended pole heights from 3 to 18 meters, correlating them with specific luminaire models (e.g., CL 2015, CL 2020, CL 2025) and indicating suitability for pole heights between 4-8 meters for the Berzelia Street CL 2070.