Aldes ISONE 1500 Ø 160 mm Fire Damper

The ISONE 1500 with ring is part of a range of flush-mounted fire dampers, certified up to 1500 Pa and optimized for high buildings.

Product Benefits

Regulations and Compliances

PV CE number: 1812-CPR-1016

Principles of Operation

The damper is open in its normal position. In case of fire, the damper closes to prevent the propagation of fire and smoke into other compartments. Its closure may be controlled thermally or centrally (scalable mechanism).

Product Description

The ISONE 1500 with ring is a flush-mounted fire damper used for the compartmentation of commercial buildings (public-access buildings, high-rise buildings, etc.). It is suited for ventilation systems operating at pressures above 500 Pa and below 1500 Pa. The range features a scalable mechanism, easy wiring using the removable terminal block, and multiple installation possibilities.

Installation

Main Characteristics

Supplementary Characteristics

Dimensional Data

VariantsA (mm)L (mm)Ø (mm)Ø opening (mm)
11043062265415160315 x 315

Diagram showing dimensions A, L, and Ø for the ISONE 1500 damper. A is indicated as 265 mm, L as 415 mm, and Ø as 160 mm. The opening diameter is specified as 315 x 315 mm. Additional dimensions show 108 mm and 50 mm offsets.

Installation Diagrams

Diagrams illustrating installation in concrete walls and slabs. The diagrams show the damper positioned within the wall or slab structure, with annotations indicating the setup for different scenarios.

PDF preview unavailable. Download the PDF instead.

EN-EXPORT-Aldes-ISONE-1500-O-160-mm-11043062 Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)

Related Documents

Preview Aldes ISONE 1500 Ø 450 mm Fire Damper - Technical Specifications and Installation
Detailed technical specifications, benefits, and installation guidelines for the Aldes ISONE 1500 Ø 450 mm fire damper, designed for high-rise buildings and high-pressure ventilation systems.
Preview Aldes ISONE 1500 Ø 200 mm Fire Damper - Technical Specifications and Installation
Detailed technical specifications, benefits, and installation guidelines for the Aldes ISONE 1500 Ø 200 mm fire damper, designed for high-rise buildings and ventilation systems up to 1500 Pa.
Preview Aldes ISONE 1500 Ø 800 mm Fire Damper - Technical Specifications
Detailed technical specifications and installation guidelines for the Aldes ISONE 1500 Ø 800 mm fire damper, designed for high-rise buildings and ventilation systems operating at pressures up to 1500 Pa.
Preview Aldes ISONE 1500 Ø 1000 mm Fire Damper - Technical Specifications
Detailed technical specifications and installation guidelines for the Aldes ISONE 1500 Ø 1000 mm fire damper, designed for high-rise buildings and ventilation systems up to 1500 Pa.
Preview Aldes ISONE 1500 Ø 500 mm Fire Damper - Technical Specifications and Installation
Detailed information on the Aldes ISONE 1500 Ø 500 mm fire damper, including its product benefits, principles of operation, installation guidelines, main and supplementary characteristics, and regulatory compliance. Suitable for high-rise buildings and ventilation systems up to 1500 Pa.
Preview Aldes ISONE 1500 Ø 710 mm Fire Damper - Technical Specifications and Installation
Detailed information on the Aldes ISONE 1500 Ø 710 mm fire damper, including product benefits, principles of operation, technical specifications, and installation guidelines. Certified to NF-S-61937-5 and CE marked as per EN 15650.
Preview Aldes ISONE 1500 Fire Damper - Technical Specifications and Installation
Detailed technical specifications, product benefits, and installation guidelines for the Aldes ISONE 1500 fire damper with a 355 mm diameter. This document covers operational principles, main and supplementary characteristics, and regulatory compliance.
Preview Aldes ISONE 1500 Fire Damper - Technical Specifications and Installation Guide
Detailed information on the Aldes ISONE 1500 fire damper, including its technical specifications, operational principles, installation guidelines, and compliance with safety regulations. Suitable for high-rise buildings and ventilation systems up to 1500 Pa.