MASTECH MS8321A Digital Multimeter
Quick Start Guide
Company Information
EMEA: MGL EUMAN S.L., C/ Picu Castiellu, Parcelas i1-i4 33163, Argame Morcín, Asturias, Spain. Tel: +34 985-08-18-70, Email: cs.emea@mgl-intl.com
USA: MGL AMERICA, INC., 2810 Coliseum Centre Drive, Ste. 100 Charlotte, North Carolina 28217 USA. Tel: +1 833-533-5899, Email: cs.na@mgl-intl.com
United Kingdom: MGL GROUP U.K. LIMITED, 14 Weller St, London, SE1 1QU, UK. Tel: +34 985-08-18-70, Email: cs.uk@mgl-intl.com
Mexico & LATAM: MGL LATAM S.A DE CV, Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F. Tel: +1 833-533-5899, Email: cs.latam@mgl-intl.com
APAC: MGL APPA Corporation, Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan. Tel: +886 2-2508-0877, Email: cs.apac@mgl-intl.com
SKU Number: MS8321ACBGLO
1 YEAR LIMITED WARRANTY
CAT III 600V
Important Safety Precautions
Special attention should be paid when using the test and measurement instrument because improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
- Examine the measuring test leads (if present) before use. Any element of which the insulation is deteriorated (even partially), replace them with proper functional test leads.
- Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
- Before measuring current, make sure the instrument fuses are available and disconnect the power supply to the circuit test.
- Remove the batteries if the device is not used for an extended period of time, or if stored in temperatures above 45 °C. If the batteries are not removed, battery leakage can damage the device.
Specifications
Measurement | Range | Resolution | Accuracy |
---|---|---|---|
V- (DC Voltage) | 2V/20V/200V | 1mV/10mV/0.1V | ±(0.8%+3) |
600V | 1V | ±(1.2%+3) | |
V~ (AC Voltage) | 200mV/2V/20V/200V | 0.1mV/1mV/10mV/0.1V | ±(0.7%+1) |
600V | 1V | ±(0.8%+2) | |
A- (DC Current) | 2mA/20mA | 1μA/10μA | ±(1.2%+5) |
200mA | 0.1mA | ±(1.8%+5) | |
10A | 0.01A | ±(3.0%+10) | |
A~ (AC Current) | 200μA/2mA/20mA | 0.1μA/1μA/10μA | ±(1.0%+3) |
200mA | 0.1mA | ±(1.5%+1) | |
10A | 0.01A | ±(2.0%+5) | |
Ω (Resistance) | 200Ω | 0.1Ω | ±(1.0%+3) |
2kΩ/20kΩ/200kΩ | 1Ω/10Ω | ±(1.0%+1) | |
20MΩ | 10kΩ | ±(1.0%+5) |
Basic Operations
Battery Installation:
The image shows the back of the multimeter being opened to insert batteries.
DC Voltage (V=) Measurement:
The image shows the test leads connected to the multimeter for DC voltage measurement, with the dial set to V= and a reading of 220.
AC Voltage (V~) Measurement:
The image shows the test leads connected to the multimeter for AC voltage measurement, with the dial set to V~ and a reading of 220.
DC Current (A-) Measurement:
The image shows the test leads connected to the multimeter for DC current measurement, with the dial set to -A and a reading of 2.53.
AC Current (A~) Measurement:
The image shows the test leads connected to the multimeter for AC current measurement, with the dial set to ~A and a reading of 2.53.
hFE (Transistor Test) Measurement:
The image shows a transistor being inserted into the hFE socket on the multimeter, with a reading of 27.01.
Continuity Test ( ))) ):
The image shows the test leads connected for a continuity test, with the dial set to the continuity symbol and a reading of 35.
Resistance (Ω) Measurement:
The image shows the test leads connected for resistance measurement, with the dial set to Ω and a reading of 500.
Related Documents
![]() |
Mastech MS8301A Digital Multimeter Quick Start Guide A quick start guide for the Mastech MS8301A Digital Multimeter, covering safety precautions, specifications, and basic measurement procedures for voltage, current, and resistance. |
![]() |
Mastech MS8229 Digital Multimeter Quick Start Guide A quick start guide for the Mastech MS8229 Digital Multimeter, covering its features, specifications, and basic usage instructions for various measurements including voltage, current, resistance, frequency, temperature, and light intensity. |
![]() |
Mastech MS8301B Digital Multimeter Quick Start Guide A quick start guide for the Mastech MS8301B Digital Multimeter, covering safety precautions, specifications, and basic measurement procedures for voltage, current, resistance, capacitance, frequency, duty cycle, and temperature. |
![]() |
Mastech MY68 Digital Multimeter Quick Start Guide A quick start guide for the Mastech MY68 Digital Multimeter, covering specifications, safety precautions, and basic usage instructions for various measurement functions. |
![]() |
MASTECH MS8238H Digital Multimeter Quick Start Guide This Quick Start Guide provides essential information for the MASTECH MS8238H Digital Multimeter. It covers safety precautions, specifications, and operational steps for various measurement functions, including voltage, current, resistance, and temperature, along with special features like wireless linking and non-contact voltage detection. |
![]() |
Mastech MS820L Digital Multimeter Quick Start Guide Quick start guide for the Mastech MS820L Digital Multimeter, covering safety precautions, specifications, and basic usage instructions for voltage, current, and resistance measurements. |
![]() |
Mastech MAS830B Digital Multimeter Quick Start Guide A quick start guide for the Mastech MAS830B Digital Multimeter, covering its specifications, safety precautions, and basic usage for measuring voltage, current, and resistance. |
![]() |
MASTECH MAS830L Digital Multimeter Quick Start Guide This guide provides quick start instructions for the MASTECH MAS830L Digital Multimeter, covering its specifications, safety precautions, and basic usage for voltage, current, and resistance measurements. |