Mastech MS8301B Digital Multimeter Quick Start Guide

This guide provides essential information for the safe and effective use of the Mastech MS8301B Digital Multimeter.

Safety Precautions

Special attention should be paid when using this test and measurement instrument, as improper usage may cause electric shock and damage the equipment.

Specifications

Function Range Resolution Accuracy
V= (DC Voltage) 400mV/4V/40V/400V 1mV/10mV/0.1V/1V ±(0.5%+3)
600V 1V ±(0.8%+3)
A= (DC Current) 400μA/4000μA/40mA/400mA 0.1μA/1μA/0.01mA/0.1mA ±(1.0%+5)
10A 0.01A ±(2.0%+10)
V~ (AC Voltage) 400mV/4V/40V/400V 1mV/10mV/0.1V/1V ±(1.0%+5)
600V 1V ±(1.0%+5)
A~ (AC Current) 400μA/4000μA/40mA/400mA 0.1μA/1μA/0.01mA/0.1mA ±(1.2%+5)
10A 0.01A ±(2.5%+10)
Ω (Resistance) 400Ω/4kΩ/40kΩ 0.1Ω/0.001kΩ/0.01kΩ ±(0.8%+5)
400kΩ/4MΩ/40MΩ 0.1kΩ/0.001MΩ/0.01MΩ ±(0.8%+5)
C (Capacitance) 5nF/50nF/500nF 0.001nF/0.01nF/0.1nF ±(3.0%+5)
5μF/50μF/100μF 0.001μF/0.01μF/0.1μF ±(3.0%+5)
Hz (Frequency) 50Hz/500Hz/10kHz 0.01Hz/0.1Hz/0.001KHz ±(1.5%+5)
Hz % (Duty Cycle) 0.1%~99% 0.1% ±(3.0%+0)
°F (Temperature) -4°F~1832°F 1°F ±(3.0%+3)

Specifications are subject to change without notification.

Basic Measurement Operations

The following diagrams illustrate basic measurement operations:

DC Voltage Measurement:

Connect the red test lead to the VΩmA port and the black test lead to the COM port. Select the DC voltage function (V=). Connect the test leads across the component to be measured. The multimeter displays the voltage. Example: 220V.

AC Voltage Measurement:

Connect the red test lead to the VΩmA port and the black test lead to the COM port. Select the AC voltage function (V~). Connect the test leads across the component to be measured. The multimeter displays the voltage. Example: 27.01V.

DC Current Measurement:

Connect the red test lead to the mA or A port (depending on the expected current) and the black test lead to the COM port. Select the DC current function (A=). Break the circuit and connect the multimeter in series with the load. The multimeter displays the current. Example: 2.53A.

Resistance Measurement:

Connect the red test lead to the VΩmA port and the black test lead to the COM port. Select the resistance function (Ω). Connect the test leads across the component to be measured. The multimeter displays the resistance. Example: 0.6Ω, 500Ω, 22Ω.

Capacitance Measurement:

Connect the red test lead to the VΩmA port and the black test lead to the COM port. Select the capacitance function (C). Connect the test leads across the capacitor to be measured. The multimeter displays the capacitance. Example: 50.12μF.

Temperature Measurement:

Connect the temperature probe to the VΩmA port (red) and COM port (black). Select the temperature function (°F). Insert the probe into the environment or onto the object to measure temperature. The multimeter displays the temperature. Example: 90°F.

Frequency/Duty Cycle Measurement:

Connect the red test lead to the VΩmA port and the black test lead to the COM port. Select the frequency/duty cycle function (Hz/%). Connect the test leads across the signal source. The multimeter displays the frequency or duty cycle. Example: 62%.

Product Information

Model: MS8301B Digital Multimeter

Brand: Mastech

Measurement Category: CAT III 600V

Warranty: 1 YEAR LIMITED WARRANTY

Certifications: CE, EAC, Intertek CA

Models: MS8301B, Digital Multimeter, MS8301B Digital Multimeter

PDF preview unavailable. Download the PDF instead.

KuLSMoROKNCrgifcIceenG0ouPNnOIS34MzYuXkl Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview Mastech MS8229 Digital Multimeter Quick Start Guide
A quick start guide for the Mastech MS8229 Digital Multimeter, covering its features, specifications, and basic usage instructions for various measurements including voltage, current, resistance, frequency, temperature, and light intensity.
Preview Mastech MY68 Digital Multimeter Quick Start Guide
A quick start guide for the Mastech MY68 Digital Multimeter, covering specifications, safety precautions, and basic usage instructions for various measurement functions.
Preview Mastech MS820L Digital Multimeter Quick Start Guide
Quick start guide for the Mastech MS820L Digital Multimeter, covering safety precautions, specifications, and basic usage instructions for voltage, current, and resistance measurements.
Preview Mastech MS8301A Digital Multimeter Quick Start Guide
A quick start guide for the Mastech MS8301A Digital Multimeter, covering safety precautions, specifications, and basic measurement procedures for voltage, current, and resistance.
Preview Mastech MS8321A Digital Multimeter Quick Start Guide
Quick start guide for the Mastech MS8321A Digital Multimeter, covering safety precautions, specifications, and basic usage instructions for voltage, current, and resistance measurements.
Preview Mastech MAS830B Digital Multimeter Quick Start Guide
A quick start guide for the Mastech MAS830B Digital Multimeter, covering its specifications, safety precautions, and basic usage for measuring voltage, current, and resistance.
Preview MASTECH MAS830L Digital Multimeter Quick Start Guide
This guide provides quick start instructions for the MASTECH MAS830L Digital Multimeter, covering its specifications, safety precautions, and basic usage for voltage, current, and resistance measurements.
Preview MASTECH MAS830B Digital Multimeter Quick Start Guide
A quick start guide for the MASTECH MAS830B Digital Multimeter, covering safety precautions, specifications, and basic measurement procedures for voltage, current, and resistance.