MASTECH MAS830L Digital Multimeter
Quick Start Guide
Company Information
MGL Group
- EMEA: MGL EUMAN S.L., Spain, Tel: +34 985-08-18-70, Email: cs.emea@mgl-intl.com
- USA: MGL AMERICA, INC., USA, Tel: +1 833-533-5899, Email: cs.na@mgl-intl.com
- United Kingdom: MGL GROUP U.K. LIMITED, UK, Tel: +34 985-08-18-70, Email: cs.uk@mgl-intl.com
- Mexico & LATAM: MGL LATAM S.A DE CV, Mexico, Tel: +1 833-533-5899, Email: cs.latam@mgl-intl.com
- APAC: MGL APPA Corporation, Taiwan, Tel: +886 2-2508-0877, Email: cs.apac@mgl-intl.com
SKU Number: MAS830LCBGLO
Specifications are subject to change without notification.
Warranty: 1 YEAR LIMITED WARRANTY
Safety Category: CAT II 600V
Important Safety Precautions
Special attention should be paid when using the test and measurement instrument because improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling test probes and crocodile clips, keep fingers behind the physical guard.
- Examine test leads before use. Replace any with deteriorated insulation.
- Connect the common test lead before the live test lead, and remove the live test lead before the common test lead.
- Before measuring current, ensure instrument fuses are available and disconnect power to the circuit.
- Remove batteries if the device is not used for an extended period or if stored above 45°C to prevent damage from battery leakage.
(This section is translated into Spanish, French, Chinese, Japanese, and Russian in the original document.)
Specifications
Measurement | Range | Resolution | Accuracy |
---|---|---|---|
Voltage (V=) | 200mV/2V/20V/200V/600V | 0.1mV/1mV/10mV/0.1V/1V | ±(0.5%+3) / ±(0.8%+5) / ±(1.2%+10) |
Current (A=) | 20μA/200μA/2mA/10mA/10A | 0.01μA/0.1μA/1μA/0.1mA/10mA | ±(1.0%+3) / ±(1.5%+5) / ±(3.0%+10) |
Resistance (Ω) | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ | 0.1Ω/1Ω/10Ω/100Ω/1kΩ | ±(0.8%+5) / ±(0.8%+2) / ±(1.0%+5) |
Basic Operations
The following diagrams illustrate basic operations:
[Diagram showing battery installation]
[Diagram showing DC Voltage measurement setup]
[Diagram showing AC Voltage measurement setup]
[Diagram showing DC Current measurement setup]
[Diagram showing Resistance measurement setup]
[Diagram showing Continuity Test setup]
[Diagram showing Transistor hFE measurement setup]