Model Numbers: CPH3H-36CD(O) (37A) / AC3-3636B-SG3 (32X)

Document Type: Submittal Data Sheet

Certifications

The system is certified by AHRI and features ENERGY STAR compliance. It is also listed by Intertek.

Efficiency Specifications

MetricRating
SEER215.8
EER210.7
HSPF2-49.4
COP3.3

Performance of Cooling

ParameterValue
Rated Capacity (Btu/hr)36,000
Min/Max Capacity (Btu/hr)12,100~41,000
Moisture Removal (L/h)4.91
Standard Operating Range (°F/°C)-22~122 (-30~50)
Rated Cooling ConditionsIndoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Performance of Heating

ParameterValue
Rated Heating (Btu/hr)38,000
@ 47°F Rated Heating (Btu/hr)38,000
@ 47°F Min/Max Capacity (Btu/hr)11,500~46,000
@ 17°F Rated Heating (Btu/hr)29,200
@ 5°F Rated: Capacity / COP36,000 / 1.9
@ 5°F Max: Capacity (Btu/hr)36,000
Standard Operating Range (°F/°C)-22~75 (-30~24)
1. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
2. Rated Heating ConditionsIndoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
3. Heating Conditions, Compressor Operating at Max. FrequencyIndoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Indoor Unit Specifications

ParameterIndoor Unit (Base Model)Package (Base Model)Net/Gross Weight
InchmmInchmmlbskg
Dimension (W×D×H)17-1/2 x 21 x 23-1/2445 × 533 × 59920-1/2 x 26-1/8 x 26-3/8520 × 665 × 67059.5 / 6827 / 30.9

Outdoor Unit Specifications

ParameterDimension (W×D×H)Package (W×D×H)Net/Gross Weight
InchmmInchmmlbskg
Compressor TypeTWIN-ROTARY
Compressor ModelEKPQ420D1UMUA
RefrigerantR454B
Refrigerant Oil Charge (mL)1460
Refrigerant OilVG75
Outdoor Air Flow (Max) (CFM)3,002
Outdoor Noise Level (dBA)64
Dimension (W×D×H)38-9/16 x 16-3/8 x 38-3/8980 × 415 × 97545-1/16 x 19-11/16 x 42-1/21145 × 500 × 1080204 / 23592.6 / 106.7

Electrical Specifications

ParameterValue
Indoor Power Supply24V, 60Hz, 1Ph
Indoor MCA/
Indoor MOP/
Outdoor Power Supply208/230, 60Hz, 1Ph
Outdoor MCA29
Outdoor MOP30
Communication WiringAWG 20-2
Compressor RLA20.5
Outdoor Fan Motor RLA2.4
Outdoor Fan Motor W/
Indoor Fan Motor RLA/
Indoor Fan Motor W/
System Power Input @ Cooling (W)3,364 (1,020 ~ 4,520)
System Power Input @ Heating (W)3,375 (800 ~ 4,540)
MCA: Min. circuit amps (A)/
RLA: Rated load amps (A)/
MOCP: Max. over current protection (A)/
W: Fan motor rated output (W)/

Piping Specifications

ParameterValue
Throttle type (Indoor)EXV
Throttle type (Outdoor)EXV
Liquid Size9.52mm (3/8in)
Gas Size19mm (3/4in)
Max. Piping Length (ft/m)246 (75)
Max. Height Difference (ft/m)98 (30)
Max. Pre-charged Length (ft/m)24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg)126.99 (3.6)
Additional Charge of Refrigerant ((oz/ft)/(g/m))0.7 (65)
Connection MethodFlared

Features

  • Multi-position installation: horizontal (left or right), vertical (up or down)
  • Aluminum Coil
  • R454B refrigerant sensor
  • Easy Maintenance
  • Multiple control options available:
    • Two-way communication wired controller with built-in WiFi: AWC-8P-LC-WIFI
    • Third-Party 24V Thermostat

Diagram Descriptions

Indoor Unit Dimensions

This section details the physical dimensions for various indoor unit models. The dimensions are provided in inches and millimeters for: Model Height, Model Width, Supply Air Opening Width, Return Air Opening Width, Condensate Drains Height, and Liquid Line Height. Specific models covered include: MVBM-24B18T3N10, MVBM-24A18T3N10, MVBM-36A24T4N10, MVBM-36B24T4N10, MVBM-36C24T4N10, and MVBM-60D28T6N10.

Outdoor Unit Dimensions

This section provides the overall dimensions for the outdoor unit, including width, depth, and height. It also indicates the location of key components such as the service panel, liquid refrigerant pipe joint, gas refrigerant pipe joint, handle, and bolt pitch for installation. Specific measurements are provided in inches and millimeters.

Outdoor Unit Installation Clearance Requirements

The outdoor unit requires specific clearances for proper operation and maintenance. These clearances are:

  • 20 inches (500mm) or more when the front and sides of the unit are clear.
  • 4 inches (100mm) or more on the sides.
  • 14 inches (350mm) or more at the rear.
  • 20 inches (500mm) or more when any two sides (left, right, and rear) of the unit are clear.
✔️ The system meets all specified spatial requirements for installation clearance.

PDF preview unavailable. Download the PDF instead.

Submittal CPH3H-36CDO-37A-AC3-3636B-SG3-32X 20250625

Related Documents

Preview ComfortStar CPH3H-36CD(O)/CWM3-36-SG3 Air Handler Heat Pump System Submittal Data Sheet
Detailed submittal data sheet for the ComfortStar CPH3H-36CD(O) and CWM3-36-SG3 Air Handler Heat Pump System, including specifications, performance data, dimensions, electrical, and piping information.
Preview ComfortStar Air Handler Heat Pump System Submittal Data Sheet: CPH3H-36CD(O) / AC3-3636A-SG3
Detailed submittal data sheet for the ComfortStar CPH3H-36CD(O) and AC3-3636A-SG3 Air Handler Heat Pump System, including efficiency, performance, electrical, piping, and dimension specifications.
Preview ComfortStar CPH3H-36CD(O) Air Handler Heat Pump System Data Sheet
Detailed submittal data sheet for the ComfortStar CPH3H-36CD(O) and CPK3-36-SG3 Air Handler Heat Pump System, including specifications, performance data, and dimensions.
Preview ComfortStar Air Handler Heat Pump System Submittal Data Sheet AHU3-36-SG3 CPH3-36CD
Detailed submittal data sheet for the ComfortStar AHU3-36-SG3 / CPH3-36CD Air Handler Heat Pump System, including efficiency ratings, performance specifications, dimensions, electrical, and piping information.
Preview ComfortStar Split Duct Air Conditioner: Owner's Manual & Installation Guide
This comprehensive manual from ComfortStar details the installation, operation, and maintenance of their split horizontal-vertical duct air conditioning units (AC3 series). It includes vital safety information, unit specifications, troubleshooting tips, and wiring guidance for models such as AC3-1824A-SG3.
Preview ComfortStar CPH3-18CD(O) (27N) / CWM3-18-SG3 Air Handler Heat Pump System Submittal Data Sheet
Detailed submittal data sheet for the ComfortStar CPH3-18CD(O) (27N) / CWM3-18-SG3 Air Handler Heat Pump System, including efficiency ratings, performance specifications, dimensions, electrical data, piping information, and features.
Preview ComfortStar SEF3-SG3 Series Air Handler Installation Manual
This installation manual from ComfortStar provides comprehensive guidance for installing the SEF3-SG3 Series Air Handler Air Conditioners. It details safety precautions, product overview, installation steps, refrigerant piping, wiring, air evacuation, and test run procedures to ensure proper setup and operation.
Preview ComfortStar TIP24/CHF24CD(O) 24,000 BTU/H Heat Pump Submittal Data Sheet
Submittal data sheet for the ComfortStar TIP24/CHF24CD(O) 24,000 BTU/H Wall Mounted Heat Pump System. Provides detailed specifications for system performance, electrical, refrigerant, indoor unit, and outdoor unit components, including dimensions and features.