Indoor Specification
Specification | Value |
---|---|
ESP (in.W.G) | 0-0.8 |
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) | 1189.0 / 1083.0 / 971.2 / 865.2 / 865.2 |
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) | 52 / 52 / 48.5 / 36.5 / 36.5 |
Dimension (W×D×H) (inch) | 22.01 x 19.02 x 40.04 |
Dimension (W×D×H) (mm) | 559 x 483 x 1017 |
Package Dimension (W×D×H) (inch) | 24.61 x 22.83 x 46.97 |
Package Dimension (W×D×H) (mm) | 625 x 580 x 1193 |
Net/Gross Weight (lbs) | 109.57 / 130.73 |
Net/Gross Weight (kg) | 49.7 / 59.3 |
Outdoor Specification
Specification | Value |
---|---|
Compressor Type | TWIN-ROTARY |
Compressor Model | EKPQ420D1UMUA |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 1460 |
Refrigerant Oil | VG74 |
Outdoor Air Flow (Max) (CFM) | 3001.9 |
Outdoor Noise Level (dBA) | 64 |
Dimension (W×D×H) (inch) | 38.58 x 16.34 x 38.39 |
Dimension (W×D×H) (mm) | 980 x 415 x 975 |
Package Dimension (W×D×H) (inch) | 45.08 x 19.69 x 42.52 |
Package Dimension (W×D×H) (mm) | 1145 x 500 x 1080 |
Net/Gross Weight (lbs) | 204.15 / 235.23 |
Net/Gross Weight (kg) | 92.6 / 106.7 |
Efficiency
Cooling | Heating | ||
---|---|---|---|
SEER2 | 16.8 | HSPF2-4 | 9.6 |
EER2 | 11.2 | COP | 3.4 |
Performance of Cooling
Specification | Value |
---|---|
Cooling (Btu/hr) | 36000 |
Rated Capacity | 36000 |
Min/Max Capacity | 13700~41500 |
Moisture Removal (L/h) | 3.47 |
Standard Operating Range (°F/°C) | -22~122 (-30~50) |
Rated Cooling Conditions: | Indoor: 80°F DB / 67°F WB; Outdoor: 95°F DB / 75°F WB |
Performance of Heating
Specification | Value |
---|---|
Heating (Btu/hr) | 37000 |
1. @ 47°F Rated | 37000 |
2. @ 47°F Min/Max Capacity | 10100~48500 |
3. @ 17°F Rated | 30200 |
4. @ 5°F Rated: Capacity / COP | 34600 / 1.8 |
5. @ 5°F Max: Capacity | 34600 |
Standard Operating Range (°F/°C) | -22~75 (-30~24) |
1. Rated Heating Conditions: | Indoor: 70°F DB / 60°F WB; Outdoor: 47°F DB / 43°F WB |
2. Rated Heating Conditions: | Indoor: 70°F DB / 60°F WB; Outdoor: 17°F DB / 15°F WB |
3. Heating Conditions, Compressor Operating at Max. Frequency | Indoor: 70°F DB / 60°F WB; Outdoor: 5°F DB / 5°F WB |
Electrical
Specification | Value |
---|---|
Indoor Power Supply | 115V / 208-230V, 60Hz, 1Ph |
Indoor MCA (115V / 208-230V) | 6.5 |
Indoor MOP | 15 |
Outdoor Power Supply | 208-230V, 60Hz, 1Ph |
Outdoor MCA | 29 |
Outdoor MOP | 30 |
Communication Wiring | AWG 20-2 |
Compressor RLA | 20.5 |
Outdoor Fan Motor RLA | 2.4 |
Outdoor Fan Motor W | / |
Indoor Fan Motor RLA | 5 |
Indoor Fan Motor W | 375 |
System Power Input @ Cooling (W) | 3214 (1170~4400) |
System Power Input @ Heating (W) | 3189 (725~4420) |
MCA: Min. circuit amps (A) | [Not explicitly listed, refer to Indoor/Outdoor MCA] |
RLA: Rated load amps (A) | [Not explicitly listed, refer to Compressor/Fan Motor RLA] |
MOCP: Max. over current protection (A) | [Not explicitly listed] |
W: Fan motor rated output (W) | [Not explicitly listed, refer to Indoor/Outdoor Fan Motor W] |
Piping
Specification | Value |
---|---|
Throttle type (Indoor) | EXV |
Throttle type (Outdoor) | EXV |
Liquid Size | 9.52mm (3/8in) |
Gas Size | 19mm (3/4in) |
Max. Piping Length (ft/m) | 246 (75) |
Max. Height Difference (ft/m) | 98.40 (30) |
Max. Pre-charged Length (ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/kg) | 126.99 (3.6) |
Additional Charge of Refrigerant ((oz/ft) / (g/m)) | 0.7 (65) |
Connection Method | Flared |
Indoor Unit Dimensions
Diagram showing front and side views of the indoor unit with dimension lines labeled A through J, indicating Height, Width, Depth, and opening sizes.
Dimension Label | Model (Btu/h) | 18K / 24K (inch) | 18K / 24K (mm) | 30K / 36K (inch) | 30K / 36K (mm) |
---|---|---|---|---|---|
A: Model Height | 36.5 | 928 | 49 | 1017 | |
B: Model Width | 20.3 | 515 | 21 | 559 | |
C: Supply Air Opening Width | 17.4 | 442 | 18.8 | 478.6 | |
D: Return Air Opening Width | 19.4 | 493.8 | 21.2 | 537.8 | |
E: Model Depth | 15.7 | 399 | 21 | 483 | |
F: Supply Air Opening Depth | 10.4 | 265.2 | 9.3 | 235.4 | |
G: Return Air Opening Depth | 10.3 | 261 | 13.1 | 332.5 | |
H: Supply Air Opening Clearance | 1.1 | 29.1 | 1.6 | 41 | |
J: Return Air Opening Side Clearance | 0.42 | 10.6 | 0.42 | 10.6 | |
K: Return Air Opening Front Clearance | 0.47 | 12 | 0.63 | 16 |
Outdoor Unit Dimensions and Installation Instructions
Diagrams showing multiple views (front, side, top) of the outdoor unit with dimensions labeled. Detail views show pipe connections and mounting points. Installation instructions indicate required clearances around the unit.
Installation Clearance Requirements:
- 4 inches (100mm) or more clearance on sides and front.
- 20 inches (500mm) or more clearance when any 2 sides (left, right, and rear) of the unit are clear.
- 14 inches (350mm) or more clearance on the rear.
- 20 inches (500mm) or more clearance when front and sides of the unit are clear.
✔️ Meets all spatial requirements shown in Installation Clearance Requirements above.
Fan Performance for Indoor Unit (36K Model)
Graph showing Air flow rate (CFM) on the Y-axis versus External static pressure (in.w.c.) on the X-axis. Four lines represent different fan speeds: Turbo, H (High), M (Medium), and L (Low). The lines are generally flat, indicating that the airflow remains relatively consistent across the tested range of external static pressures for each speed setting.
Features
- Multi-position of return air: front (factory standard) or bottom.
- Aluminum Coil.
- Constantly Air Flow system up to 0.80 In.W.G.
- Optional Auxiliary heat kit up to 10kW.
- Easy Maintenance.
- Multiple control options available:
- Two-way communication wired controller: AWC-4
- Two-way communication wired controller with built-in WiFi: AWC-8P-LC-WIFI
- Wireless remote controller
- Third-Party 24V Thermostat
- High efficiency up to 19.3 SEER2, 12.1 EER2, 10.8 HSPF2.
- Chassis heater and crankcase heater equipped as standard.