ComfortStar Air Handler Heat Pump System

SUBMITTAL DATA SHEET

Model Numbers: CPH3H-36CD(O) (37A) / CWM3-36-SG3 (32G)

Product Type: Air Handler Heat Pump System

Project Information

Location: [Not Specified]

Engineer: [Not Specified]

Submitted to: [Not Specified]

Submitted by: [Not Specified]

Reference: [Not Specified]

Approval: [Not Specified]

Date: [Not Specified]

Construction: [Not Specified]

Unit #: [Not Specified]

Drawing #: [Not Specified]

Certifications

Certifications: AHRI CERTIFIED (w.ahridirectory.org), ENERGY STAR, ETL LISTED

Product Images

Image of the indoor unit: A rectangular, white cabinet with controls and air vents visible on the front. Image of the outdoor unit: A compact, white rectangular unit with a fan grille on one side and service panels.

Indoor Specification

Specification Value
ESP (in.W.G) 0-0.8
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) 1189.0 / 1083.0 / 971.2 / 865.2 / 865.2
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) 52 / 52 / 48.5 / 36.5 / 36.5
Dimension (W×D×H) (inch) 22.01 x 19.02 x 40.04
Dimension (W×D×H) (mm) 559 x 483 x 1017
Package Dimension (W×D×H) (inch) 24.61 x 22.83 x 46.97
Package Dimension (W×D×H) (mm) 625 x 580 x 1193
Net/Gross Weight (lbs) 109.57 / 130.73
Net/Gross Weight (kg) 49.7 / 59.3

Outdoor Specification

Specification Value
Compressor Type TWIN-ROTARY
Compressor Model EKPQ420D1UMUA
Refrigerant R454B
Refrigerant Oil Charge (mL) 1460
Refrigerant Oil VG74
Outdoor Air Flow (Max) (CFM) 3001.9
Outdoor Noise Level (dBA) 64
Dimension (W×D×H) (inch) 38.58 x 16.34 x 38.39
Dimension (W×D×H) (mm) 980 x 415 x 975
Package Dimension (W×D×H) (inch) 45.08 x 19.69 x 42.52
Package Dimension (W×D×H) (mm) 1145 x 500 x 1080
Net/Gross Weight (lbs) 204.15 / 235.23
Net/Gross Weight (kg) 92.6 / 106.7

Efficiency

Cooling Heating
SEER2 16.8 HSPF2-4 9.6
EER2 11.2 COP 3.4

Performance of Cooling

Specification Value
Cooling (Btu/hr) 36000
Rated Capacity 36000
Min/Max Capacity 13700~41500
Moisture Removal (L/h) 3.47
Standard Operating Range (°F/°C) -22~122 (-30~50)
Rated Cooling Conditions: Indoor: 80°F DB / 67°F WB; Outdoor: 95°F DB / 75°F WB

Performance of Heating

Specification Value
Heating (Btu/hr) 37000
1. @ 47°F Rated 37000
2. @ 47°F Min/Max Capacity 10100~48500
3. @ 17°F Rated 30200
4. @ 5°F Rated: Capacity / COP 34600 / 1.8
5. @ 5°F Max: Capacity 34600
Standard Operating Range (°F/°C) -22~75 (-30~24)
1. Rated Heating Conditions: Indoor: 70°F DB / 60°F WB; Outdoor: 47°F DB / 43°F WB
2. Rated Heating Conditions: Indoor: 70°F DB / 60°F WB; Outdoor: 17°F DB / 15°F WB
3. Heating Conditions, Compressor Operating at Max. Frequency Indoor: 70°F DB / 60°F WB; Outdoor: 5°F DB / 5°F WB

Electrical

Specification Value
Indoor Power Supply 115V / 208-230V, 60Hz, 1Ph
Indoor MCA (115V / 208-230V) 6.5
Indoor MOP 15
Outdoor Power Supply 208-230V, 60Hz, 1Ph
Outdoor MCA 29
Outdoor MOP 30
Communication Wiring AWG 20-2
Compressor RLA 20.5
Outdoor Fan Motor RLA 2.4
Outdoor Fan Motor W /
Indoor Fan Motor RLA 5
Indoor Fan Motor W 375
System Power Input @ Cooling (W) 3214 (1170~4400)
System Power Input @ Heating (W) 3189 (725~4420)
MCA: Min. circuit amps (A) [Not explicitly listed, refer to Indoor/Outdoor MCA]
RLA: Rated load amps (A) [Not explicitly listed, refer to Compressor/Fan Motor RLA]
MOCP: Max. over current protection (A) [Not explicitly listed]
W: Fan motor rated output (W) [Not explicitly listed, refer to Indoor/Outdoor Fan Motor W]

Piping

Specification Value
Throttle type (Indoor) EXV
Throttle type (Outdoor) EXV
Liquid Size 9.52mm (3/8in)
Gas Size 19mm (3/4in)
Max. Piping Length (ft/m) 246 (75)
Max. Height Difference (ft/m) 98.40 (30)
Max. Pre-charged Length (ft/m) 24.6 (7.5)
Refrigerant Pre-charged Amount (oz/kg) 126.99 (3.6)
Additional Charge of Refrigerant ((oz/ft) / (g/m)) 0.7 (65)
Connection Method Flared

Indoor Unit Dimensions

Diagram showing front and side views of the indoor unit with dimension lines labeled A through J, indicating Height, Width, Depth, and opening sizes.

Dimension Label Model (Btu/h) 18K / 24K (inch) 18K / 24K (mm) 30K / 36K (inch) 30K / 36K (mm)
A: Model Height 36.5 928 49 1017
B: Model Width 20.3 515 21 559
C: Supply Air Opening Width 17.4 442 18.8 478.6
D: Return Air Opening Width 19.4 493.8 21.2 537.8
E: Model Depth 15.7 399 21 483
F: Supply Air Opening Depth 10.4 265.2 9.3 235.4
G: Return Air Opening Depth 10.3 261 13.1 332.5
H: Supply Air Opening Clearance 1.1 29.1 1.6 41
J: Return Air Opening Side Clearance 0.42 10.6 0.42 10.6
K: Return Air Opening Front Clearance 0.47 12 0.63 16

Outdoor Unit Dimensions and Installation Instructions

Diagrams showing multiple views (front, side, top) of the outdoor unit with dimensions labeled. Detail views show pipe connections and mounting points. Installation instructions indicate required clearances around the unit.

Installation Clearance Requirements:

✔️ Meets all spatial requirements shown in Installation Clearance Requirements above.

Fan Performance for Indoor Unit (36K Model)

Graph showing Air flow rate (CFM) on the Y-axis versus External static pressure (in.w.c.) on the X-axis. Four lines represent different fan speeds: Turbo, H (High), M (Medium), and L (Low). The lines are generally flat, indicating that the airflow remains relatively consistent across the tested range of external static pressures for each speed setting.

Features

PDF preview unavailable. Download the PDF instead.

Submittal CPH3H-36CDO-37A-CWM3-36-SG3-32G 20250625

Related Documents

Preview ComfortStar CPH3H-36CD(O) Air Handler Heat Pump System Data Sheet
Detailed submittal data sheet for the ComfortStar CPH3H-36CD(O) and CPK3-36-SG3 Air Handler Heat Pump System, including specifications, performance data, and dimensions.
Preview ComfortStar CWM3-SG3 Series Air-Handler Owner's Manual
This owner's manual provides essential information for the safe installation, operation, and maintenance of ComfortStar CWM3-SG3 Series Wall Mount Air-Handler units, including safety precautions, unit details, operating conditions, care instructions, and troubleshooting.
Preview ComfortStar Air Handler Heat Pump System Submittal Data Sheet - CPH3H-36CD(O) / AC3-3636B-SG3
Comprehensive submittal data sheet for the ComfortStar CPH3H-36CD(O) (37A) and AC3-3636B-SG3 (32X) Air Handler Heat Pump System, detailing efficiency, performance, electrical, piping, and dimensional specifications.
Preview ComfortStar CWM3-SG3 Series Wall Mount AHU Installation Manual
Comprehensive installation manual for the ComfortStar CWM3-SG3 Series Wall Mount Air Handler Unit, covering safety precautions, installation procedures, wiring, and testing for models like CWM3-18-SG3, CWM3-24-SG3, CWM3-30-SG3, and CWM3-36-SG3.
Preview ComfortStar Air Handler Heat Pump System Submittal Data Sheet: CPH3H-36CD(O) / AC3-3636A-SG3
Detailed submittal data sheet for the ComfortStar CPH3H-36CD(O) and AC3-3636A-SG3 Air Handler Heat Pump System, including efficiency, performance, electrical, piping, and dimension specifications.
Preview ComfortStar CPH3-18CD(O) (27N) / CWM3-18-SG3 Air Handler Heat Pump System Submittal Data Sheet
Detailed submittal data sheet for the ComfortStar CPH3-18CD(O) (27N) / CWM3-18-SG3 Air Handler Heat Pump System, including efficiency ratings, performance specifications, dimensions, electrical data, piping information, and features.
Preview ComfortStar Air Handler Heat Pump System Submittal Data Sheet AHU3-36-SG3 CPH3-36CD
Detailed submittal data sheet for the ComfortStar AHU3-36-SG3 / CPH3-36CD Air Handler Heat Pump System, including efficiency ratings, performance specifications, dimensions, electrical, and piping information.
Preview ComfortStar SEF3-SG3 Series Air Handler Installation Manual
This installation manual from ComfortStar provides comprehensive guidance for installing the SEF3-SG3 Series Air Handler Air Conditioners. It details safety precautions, product overview, installation steps, refrigerant piping, wiring, air evacuation, and test run procedures to ensure proper setup and operation.