Aldes IN LINE 125 (11022327) Duct Mounted Extractor Fan
VENTILATION SIMPLE FLUX
Product Overview
Extractor Fan in Duct
Model: 11022327
Name: IN LINE 125
The IN LINE is a silent and discreet duct-mounted extractor fan. It can be used for both blowing and extraction.
Key Product Advantages:
- Visual discretion: no extractor visible in the room.
- Silent operation: from 27 dB(A).
- Extraction or blowing functionality.
Operating Principles
The IN LINE duct fan provides spot ventilation for a room, offering forced and intermittent extraction or supply. It is suitable for short duct installations.
Product Description
The IN LINE is a short duct fan that operates in extraction or blowing, providing spot ventilation for a room: bathroom, toilet, laundry room, cellar.
Application Areas
- Residential collective housing
- Residential individual housing
- Renovation projects
Installation
- Insert into a duct.
- Maximum duct length: 2 m.
- Manual on/off via a switch.
- Air supply to the room via an air inlet grille or door undercut.
Reference Argument
- Application: Spot ventilation for a room, allows extraction or blowing, forced and intermittent operation.
- Description: Material: ABS, Motor with very low acoustic level.
Main Characteristics
- 3 Diameters:
- Ø 100 mm for rooms up to 7 m².
- Ø 125 mm for rooms from 7 to 12 m².
- Ø 150 mm for rooms over 12 m².
- Manual operation: instantaneous on and off via a switch.
- Very low power consumption motor with a low acoustic level.
- Thermal protection via fuse.
- Material: ABS.
General Data
References | Number of Speeds | Motor Type |
---|---|---|
11022327 | 1 | AC |
Dimensional Data
References | A (mm) | B (mm) | D (mm) | H (mm) | L (mm) | Ø (mm) | Weight (kg) |
---|---|---|---|---|---|---|---|
11022327 | 118 | 28 | 59 | 125 | 118 | 125 | 0.43 |
Dimensional Encombrement in mm
Diagram showing dimensions a, b, and D.
Aerulic Data
References | Max Flow Rate (m³/h) |
---|---|
11022327 | 135 |
Acoustic Data
References | Sound Pressure Level at 3m (dB(A)) |
---|---|
11022327 | 32 |
Electrical Data
References | Voltage (V) | Frequency (Hz) | Max Power (W) | Protection Index (A) |
---|---|---|---|---|
11022327 | 230 | 50 | 9.3 | 2 |
Regulatory Data
References | Electrical Insulation Class |
---|---|
11022327 | Class 2 |
Performance Curves
Graph showing the relationship between airflow (Q in m³/h) and static pressure (Pa) for the IN LINE 125 fan. The curve starts at approximately 35 Pa at 0 m³/h and decreases to 0 Pa at approximately 135 m³/h.
Curve Title: Aerulic curve IN LINE 125