Aldes DESIGN 125 P: High-Performance Ventilation Extractor
Model: 11022307 | Simple Flow Ventilation
Product Overview
The DESIGN 125 P is an extra-flat spot extractor designed for intermittent ventilation of rooms such as bathrooms, WCs, laundry rooms, and kitchens. It is suitable for small to large rooms, offering three diameter options (100mm, 125mm, 150mm) and four distinct operating modes, including presence detection.
Product Highlights
- Extra-flat design
- Available with presence detection
- Silent operation: starting from 26 dB(A)
Image Description: The product is shown in two views. One view displays the front of the extractor with its grille, and the other view shows its side profile.
Principles of Operation
DESIGN spot extractors provide intermittent ventilation for rooms like bathrooms, WCs, laundry rooms, and large kitchens, depending on the selected diameter. They offer four operating modes:
- Triggering and stopping via a standard switch (Version I)
- Triggering via switch and timed stop with adjustable timer (Version T)
- Triggering via humidity threshold and timed stop with adjustable timer (Version H)
- Triggering via presence detection and timed stop with adjustable timer (Version P)
Product Description
The DESIGN range comprises extra-flat spot extractors designed for intermittent room ventilation. Suitable for bathrooms, WCs, laundry rooms, and large kitchens (depending on diameter choice), this range provides a wide selection of operating modes and diameters to meet diverse user needs.
Application Domains
- Residential collective housing
- Residential individual housing
- Renovation projects
Implementation
- Fixing: Secured by 4 supplied screws.
- Installation: Suitable for wall or ceiling mounting.
- Maximum discharge length: 2 meters.
- Operation Control: Manual and timed start/stop managed by a switch.
- Air Intake: Fresh air is introduced into the room via an air inlet grille or by undercutting the door.
Reference Argument
Application
- Spot ventilation for a single room.
- Forced and intermittent extraction.
Description
- Material: High-quality ABS front grille and body.
- Motorization: Features a low acoustic level motor.
- Non-return Flap: Removable flap located at the rear of the extractor.
- Operation (Presence Detection Version P): Timed start and stop triggered by presence detection. The detection lens has a range of 1 to 4 meters with a 100° detection angle. The operating duration is pre-settable from 2 to 30 minutes.
- Packaging: Supplied in communicative cardboard packaging.
Key Features
- Diameters: Available in Ø 100 mm (up to 7 m² rooms), Ø 125 mm (7-12 m² rooms), and Ø 150 mm (over 12 m² rooms).
- Operating Modes: Four modes available: Manual (I), Timed (T), Humidity Detection (H), and Presence Detection (P).
- Motor: Very low consumption and low acoustic level motorization.
- Non-return Flap: Removable at the rear.
- Thermal Protection: Integrated.
- Material: High-quality ABS body and ABS aesthetic face with aluminum trim (for aluminum finish).
Complementary Features
- Manual Operation (Version I): Instantaneous start and stop via a switch (not supplied).
- Timed Operation (Version T): Triggered by switch action; timed stop adjustable from 2 to 30 minutes.
- Automatic Operation with Humidity Detection (Version H): Boost mode is activated by a humidity threshold adjustable between 60% and 90%. Operation is automatic when ambient humidity exceeds the preset threshold. Timed stop is adjustable from 2 to 30 minutes. The extractor runs for the preset duration after humidity drops below the threshold before switching off.
- Automatic Operation with Presence Detection (Version P): Triggered by presence detection. Detection lens range: 1 to 4 meters; detection angle: 100°. Timed stop is adjustable from 2 to 30 minutes.
Kit Composition
- Fixing screws and dowels (4 units).
General Data
Reference | Mounting Thickness (mm) | Operation | Number of Speeds | Max Extracted Air Temp (°C) | Finish Type | Motor Type |
---|---|---|---|---|---|---|
11022307 | 17 | Automatic triggering by presence detection and timed stop | 1 | 40 | White | AC |
Dimensional Data
Reference | A (mm) | C (mm) | D (mm) | E (mm) | H (mm) | L (mm) | P (mm) | Ø Rejection (mm) | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|
11022307 | 176 | 13.5 | 87 | 17 | 176 | 176 | 117.5 | 125 | 0.73 |
Diagram Description: A technical drawing illustrates the extractor's dimensions, with labels A, C, D, E, H, L, P, and Ø rejet indicating specific measurements. The overall footprint is also represented.
Aerodynamic Data
Reference | Max Flow Rate (m³/h) | Acoustic Pressure at 3m (dB(A)) |
---|---|---|
11022307 | 115 | 31 |
Acoustic Data
Reference | Acoustic Pressure at 3m (dB(A)) |
---|---|
11022307 | 31 |
Electrical Data
Reference | Voltage (V) | Frequency (Hz) | Max Power (W) | IP Rating |
---|---|---|---|---|
11022307 | 230 | 50 | 9.3 | 2 |
Regulatory Data
Reference | Electrical Insulation Class |
---|---|
11022307 | Class 2 |
Curves
Aerodynamic Curve DESIGN 125: This graph illustrates the performance characteristics of the DESIGN 125 extractor. The Y-axis represents Pressure in Pascals (Pa), and the X-axis represents Flow Rate in cubic meters per hour (m³/h). The curve shows that as the flow rate increases from 0 m³/h, the pressure decreases from approximately 24 Pa, reaching 0 Pa at a flow rate of around 115 m³/h.