HELIONE NC-F200-F400 Ø 710
Ventilateur hélicoïde
Product Overview
The HELIONE range consists of smoke extraction centrifugal fans, available in F200-120, F400-120, or non-classified versions. The standard HELIONE range spans from Ø 355 to Ø 1250 mm, offering flow rates from 1,500 to 200,000 m³/h. These fans are suitable for ventilation and/or smoke extraction in various environments including residential buildings (parking, stairwells), tertiary sectors (parking, shops), and industrial facilities. They are designed for air extraction/supply in smoke extraction applications, particularly in areas where acoustic requirements are not paramount. The HELIONE series benefits from a wide array of accessories to facilitate installation.
Key Features:
- Flow rates up to 128,000 m³/h.
- Suitable for parking, tertiary, and industrial applications.
- Numerous accessories available for easy installation.
- CE conformity: 1812-CPR-1623.
- Classifications: F400-120 and F200-120.
Operating Principles
HELIONE fans are connected to the ventilation/smoke extraction circuit to evacuate stale air and smoke to the exterior. They can be controlled via an AXONE relay unit or a parking unit.
Product Description
The HELIONE standard range covers diameters from Ø 355 to Ø 1250 mm, with flow rates from 1,500 to 200,000 m³/h. The HELIONE is used for ventilation and/or smoke extraction in residential settings (parking, stairwells), tertiary premises (parking, shops), and industrial buildings. It is suitable for air extraction/supply for spot smoke extraction or in locations where acoustic performance is not a primary concern. The HELIONE benefits from numerous accessories that simplify its implementation.
Application Areas
Collective residential housing, New construction, Renovation, Tertiary premises.
Installation
Installation can be horizontal on the ground or wall-mounted, requiring specific accessories such as square plates, anti-vibration feet, counter-flanges, and flexible connectors or grilles if not connected.
Horizontal installation between two ducts requires anti-vibration feet, counter-flanges, and flexible connectors on both sides, with a long casing for motor access via an inspection hatch.
Wall-mounted installations require reinforced square plates for wall fixing, counter-flanges, and flexible connectors or grilles.
Vertical suspension under a slab or within a duct requires a protective grille if access is possible or if there's a risk of debris suction. A long casing is recommended for motor access if connected on both sides, and a gusset option is available.
Technical Specifications
Main Characteristics
- Conformities: F400-120 and F200-120 classification, CE conformity: 1812-CPR-1623.
- Diameter range: Ø 355 to Ø 1250 mm (for larger diameters, please consult).
- Flow rates: 1,500 to 120,000 m³/h for pressures from 100 to 600 Pa.
- Impellers: Composed of multiple aluminum blades, mounted on an aluminum hub. Blade pitch is determined based on the operating point.
- Blades: Radiographed individually by X-ray before assembly to verify material quality.
- Casings (Viroles): Formed from sheet metal, with integrated and drilled edges for connections. Standard is a short casing; long casing is optional.
- Motor mounting brackets: Hot-dip galvanized for corrosion resistance.
- Motors: Boss-mounted, 4-pole or 4/8-pole (2-pole on request), IP 55, F-class insulation as standard, operating temperature -20/50°C. 60 Hz motors available upon request.
Complementary Characteristics
- Installation accessories: Flexible connector, galvanized steel counter-flange for connecting Helione to a circular duct, galvanized steel square plate for wall mounting, galvanized steel support feet (x2), anti-vibration pads (x4) for mounting under support feet, circular 2-blade galvanized steel non-return damper, suction bell for improved aerodynamic and acoustic performance.
- Electrical accessories: Proximity switch, pressure switch, AXONE relay unit, habitat parking unit.
- Available options: Long casing, gussets for vertical mounting, pre-wired external terminal box, "sea environment / aggressive environment" finish (hot-dip galvanization, epoxy powder coating, stainless steel).
Dimensional Data
Reference | A (mm) | B (mm) | C (mm) | D (mm) | F (mm) | C long casing (mm) | D long casing (mm) | Short casing footprint (mm) | Long casing footprint (mm) |
---|---|---|---|---|---|---|---|---|---|
11090507 | 710 | 780 | 254 | 540 | 8 | 440/675 | 485/595 | 254/425 | - |
Electrical Data
Reference | Max Power (kW) | Max Current (A) | Min Power (kW) |
---|---|---|---|
11090507 | 15 | 29 | 0.55 |
Accessories List
Description | Reference |
---|---|
Non-return damper HELIONE Ø 700 | 11090574 |
Counter flange HELIONE Ø 700 | 11090535 |
GRILLE HELICE HELIONE D700 | 11090587 |
Motor grille for Short Casing | 11090600 |
Set of 2 HELIONE Feet Ø 700 | 11090522 |
Set of 4 HELIONE Pads Ø 315 - Ø 800 | 11090619 |
Flexible connector HELIONE Ø 700 | 11090548 |
Auto-transformer 14A three-phase | 11057060 |
Auto-transformer 2A three-phase | 11086096 |
Auto-transformer 4A three-phase | 11086097 |
Auto-transformer 6A three-phase | 11086098 |
Auto-transformer 8A three-phase | 11086099 |
Suction bell HELIONE Ø 700 | 11090561 |
Square plate HELIONE Ø 700 | 11090613 |
Options List
Description | Reference |
---|---|
3HL/10-10 | 3HL/10-10 |
3HL/12-12 | 3HL/12-12 |
3HL/14-14 | 3HL/14-14 |
3HL/3-6 | 3HL/3-6 |
3HL/4-8 | 3HL/4-8 |
3HL/5-10 | 3HL/5-10 |
3HL/6-12 | 3HL/6-12 |
3HL/6-6 | 3HL/6-6 |
3HL/7-14 | 3HL/7-14 |
3HL/8-8 | 3HL/8-8 |
4Z/12-12 | 4Z/12-12 |
4Z/16-16 | 4Z/16-16 |
4Z/3-9 | 4Z/3-9 |
4Z/5-5 | 4Z/5-5 |
4Z/6-12 | 4Z/6-12 |
4Z/6-9 | 4Z/6-9 |
4Z/7-7 | 4Z/7-7 |
4Z/7-7R | 4Z/7-7R |
4Z/8-16 | 4Z/8-16 |
4Z/9-9 | 4Z/9-9 |
4ZNAL/3-9 | 4ZNAL/3-9 |
4ZNAL/6-9 | 4ZNAL/6-9 |
4ZNAL/9-9 | 4ZNAL/9-9 |
5Z/12-12 | 5Z/12-12 |
5Z/16-16 | 5Z/16-16 |
5Z/3-9 | 5Z/3-9 |
5Z/5-5 | 5Z/5-5 |
5Z/6-12 | 5Z/6-12 |
5Z/6-9 | 5Z/6-9 |
5Z/8-16 | 5Z/8-16 |
5Z/9-9 | 5Z/9-9 |
6W/10-10 | 6W/10-10 |
6W/3-6 | 6W/3-6 |
6W/4-8 | 6W/4-8 |
6W/5-10 | 6W/5-10 |
6W/6-6 | 6W/6-6 |
6W/8-8 | 6W/8-8 |
9W/10-10 | 9W/10-10 |
9W/3-6 | 9W/3-6 |
9W/4-8 | 9W/4-8 |
9W/5-10 | 9W/5-10 |
9W/6-6 | 9W/6-6 |
9W/8-8 | 9W/8-8 |
OPTION GOUSSET | KW0.12 |
OPTION GOUSSET | KW0.18 |
OPTION GOUSSET | KW0.25 |
OPTION GOUSSET | KW0.37 |
OPTION GOUSSET | KW0.55 |
OPTION GOUSSET | KW0.6 |
OPTION GOUSSET | KW0.75+F4001V |
OPTION GOUSSET | KW0.75+ND1V |
OPTION GOUSSET | KW0.8+F4002V |
OPTION GOUSSET | KW0.8+ND2V |
OPTION GOUSSET | KW1.2+F2002V |
OPTION GOUSSET | KW1.2+ND2V |
OPTION GOUSSET | KW1.5+F4002V |
OPTION GOUSSET | KW1.6+F2002V |
OPTION GOUSSET | KW1.6+ND2V |
OPTION GOUSSET | KW11+F2002V |
OPTION GOUSSET | KW11+ND2V |
OPTION GOUSSET | KW14+F2002V |
OPTION GOUSSET | KW14+F4002V |
OPTION GOUSSET | KW14+ND2V |
OPTION GOUSSET | KW17+F2002V |
OPTION GOUSSET | KW17+F4002V |
OPTION GOUSSET | KW17+ND2V |
OPTION GOUSSET | KW18.5+F2001V |
OPTION GOUSSET | KW18.5+F4001V |
OPTION GOUSSET | KW18.5+ND1V |
OPTION GOUSSET | KW2.2+F2002V |
OPTION GOUSSET | KW2.2+F4002V |
OPTION GOUSSET | KW2.2+ND2V |
OPTION GOUSSET | KW20+F2002V |
OPTION GOUSSET | KW20+F4002V |
OPTION GOUSSET | KW20+ND2V |
OPTION GOUSSET | KW3+F2001V |
OPTION GOUSSET | KW3+F4001V |
OPTION GOUSSET | KW3+ND1V |
OPTION GOUSSET | KW3.8+F2002V |
OPTION GOUSSET | KW3.8+F4002V |
OPTION GOUSSET | KW3.8+ND2V |
OPTION GOUSSET | KW30+F2001V |
OPTION GOUSSET | KW30+F2002V |
OPTION GOUSSET | KW30+F4001V |
OPTION GOUSSET | KW30+ND1V |
OPTION GOUSSET | KW35+ND2V |
OPTION GOUSSET | KW37+F2001V |
OPTION GOUSSET | KW37+F2002V |
OPTION GOUSSET | KW37+F4001V |
OPTION GOUSSET | KW37+F4002V |
OPTION GOUSSET | KW37+ND1V |
OPTION GOUSSET | KW37+ND2V |
OPTION GOUSSET | KW4+F2001V |
OPTION GOUSSET | KW4+F4001V |
OPTION GOUSSET | KW4+ND1V |
OPTION GOUSSET | KW44+F2002V |
OPTION GOUSSET | KW44+F4002V |
OPTION GOUSSET | KW44+ND2V |
OPTION GOUSSET | KW45+F2001V |
OPTION GOUSSET | KW45+F4001V |
OPTION GOUSSET | KW45+ND1V |
OPTION GOUSSET | KW5+F2002V |
OPTION GOUSSET | KW5+F4002V |
OPTION GOUSSET | KW5+ND2V |
OPTION GOUSSET | KW5.5+F2001V |
OPTION GOUSSET | KW55+ND2V |
OPTION GOUSSET | KW7.2+F2002V |
OPTION GOUSSET | KW7.2+F4002V |
OPTION GOUSSET | KW7.2+ND2V |
OPTION GOUSSET | KW7.5+F2001V |
OPTION GOUSSET | KW7.5+F4001V |
OPTION GOUSSET | KW7.5+ND1V |
OPTION GOUSSET | KW9.2+ND1V |
VIROLE | VIROL2 |
Installation Diagrams
Diagrams illustrating different installation configurations are provided, including:
- Horizontal installation with short casing.
- Horizontal installation with long casing.
- Installation with optional protective grilles on both sides.
- Vertical axis mounting on a structure.
- Mounting on a structure with short casing HELIONE.
- Components shown: HELIONE fan, Support Feet, Steel Profiles, Anti-vibration pads.