Elitech IR-200 Leak Detector User Manual

Elitech IR-200 Infrared & Heated Diode Leak Detector

User Manual

Overview

The Elitech IR-200 is a versatile, hand-held, two-in-one leak detector developed by Elitech®. This advanced product integrates both infrared and heated diode sensor technologies, allowing for seamless switching between two detection modes. Compared to traditional corona or heated diode detectors, the IR-200 features a sensor with enhanced accuracy and a longer service life. It can detect a wider range of refrigerants and is designed to withstand high concentrations of refrigerants without damage. The detector boasts an ergonomic design and an innovative large TFT LCD display, optimizing the user experience and presenting detection results intuitively.

Device Components:

  • 1. Flexible Probe: The flexible probe allows for easy access to hard-to-reach areas.
  • 2. UV LED: Integrated UV LED for enhanced leak detection with UV dye.
  • 3. Filter Components: Protects the sensor from contaminants and moisture.
  • 4. Headphone Jack: For audio feedback via headphones.
  • 5. USB Port (Type-C): For charging the device.
  • 6. Display Screen: Large TFT LCD screen for clear display of readings and status.
  • 7. Buttons: Control buttons for device operation.
  • 8. Buzzer: Provides audible alerts for detected leaks.

Diagram Description: A visual representation of the Elitech IR-200 leak detector, highlighting its key external components labeled 1 through 8.

Technical Parameters

Parameter Specification
Refrigerants CFCs, HFCs, HCFC series and HFO-1234YF
Sensor life Infrared Sensor: 10 years; Heated Diode Sensor: 500 hours
Sensitivity Infrared Sensor Max 4g/a; Heated Diode Sensor Max 13g/a
Sensors Infrared & Heated Diode
Alarm Mode Audible and visual alarm
Auto OFF After 10 minutes of inactivity
Battery 2 x 18650 lithium battery
Working Hour 8 hours continuously (on a single charge)
Charging Time Approx. 4 hours
Charging Voltage/Current DC 5V, 1A
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Humidity 90%RH (non-condensing)
Operating Temperature -10°C to 52°C
Certifications CE, EN14624:2012, RoHS, SAE_J1627, SAE_J2791, SAE_J2913
Dimensions 201 x 72 x 35 mm (7.9" x 2.8" x 1.4")
Weight 450g (15.9oz)

Operation

⚠ Warning!
  • Before starting, ensure the battery is sufficiently charged for the detection (typically takes about 30 minutes per detection).
  • Ensure the system pressure is at least 340 Kpa (50 psi) before detection, as many refrigerant leaks are undetectable at low pressure.
  • Infrared Mode: Keep the detector moving during detection, as the infrared sensor detects relative gas concentrations. If concentration remains unchanged, it may not pinpoint leaks.
  • Heated Diode Mode: Move the detector slowly during detection.
  • Do not place the detector near organic solvents, detergents, or high-voltage power supplies. Wipe the detector with a clean towel.

Steps:

  1. Turn on the detector. Wait for the warm-up countdown (approx. 30 seconds) to reach optimal detection status.
  2. Identify potential leak locations, such as:
    • Joints in refrigerant lines
    • Points with changes in cross-section
    • Points with changes in vertical section
    Visually inspect the refrigerant system for lines, hoses, fittings, couplings, service valves, and signs of lubricant leaks, damage, or corrosion, as these are likely leak points.
  3. Move the probe slowly (approx. 3 ft/s or 75 mm/s) at suspicious leak points, moving back and forth within 0.25" (6mm) of the leak area. A closer probe position and slower sweeping movement improve leak detection.
  4. The buzzer and LCD display will indicate detected leaks:
    • Buzzer: Beeping frequency increases with leak intensity.
    • LCD Display: Bar graph rises with leak intensity.
  5. Follow the steps above to scan the entire refrigerant system and mark each found leak.

Display Indicators (Infrared Interface):

  • 1. Buzzer: Indicates buzzer status. Red icon: disabled; Green icon: enabled.
  • 2. Peak value: Indicates the maximum detected leakage. Note: PEAK function must be ON for peak value to display.
  • 3. Leak value: Indicates current detected leakage. Higher concentration = higher bars.
  • 4. Sensitivity level: Displays current sensitivity. Levels: H (high), M (medium), L (low).
  • 5. Battery charging status: Indicates charging progress.
  • 6. Battery level: Displays current battery level. Green: Full; Yellow: Low; Red: Extreme-low (charge ASAP).
  • 7. PEAK ON/OFF: Indicates PEAK function status. ON or OFF. Turning off PEAK clears recorded values.

Diagram Description: Visual representation of the IR-200's display in Infrared Mode, showing indicators for buzzer, peak value, leak value, sensitivity, battery status, and PEAK function.

Display Indicators (Heated Diode Interface):

  • 1. Leakage reference value: Based on detected concentration.
  • 2. Record reference value: Used to locate the maximum leakage point.

Diagram Description: Visual representation of the IR-200's display in Heated Diode Mode, showing numerical readings for leakage reference and recorded reference values.

Other Information:

  • Alert: If the sensor is faulty, the display will show "Error: Sensor".
  • Warm-up countdown: Wait approximately 30 seconds after turning on the detector until the warm-up finishes.

Maintenance

Battery Charging & Maintenance

⚠ Warning!
  • Avoid complete discharging and frequent charging, as this can affect battery life.
  • If the detector is not used for a long time, charge it beforehand to prevent battery life reduction due to self-discharging. Do not store for more than 6 months without charging.
  • Use a DC 5V/1A power adapter for charging. Full recharging time is approximately 4 hours.
  • Charging Indicator: Orange indicates charging; Green indicates fully charged. The device displays charging status when connected.
  • Performing leakage detection during charging is not recommended as it may cause false alarms.
  • The device contains two replaceable 18650 Li batteries. Reverse battery installation will cause irreversible damage.

Diagram Description: Illustration showing the detector with its back cover open, revealing the two 18650 lithium batteries inside.

Filter Replacement

The filter prevents large particle contaminants and moisture, reducing false alarms caused by humidity. Replace the filter when it becomes seriously polluted (black and clogged).

Follow these steps:

  1. Unscrew the filter components counterclockwise.
  2. Screw the filter components clockwise.

Diagram Description: Visual guide for filter replacement, showing the flexible probe and filter components with arrows indicating the counterclockwise unscrewing and clockwise screwing directions.

What's Included

  • Infrared Leak Detector: x1
  • UV LED: x1
  • User Manual: x1
  • Plastic Case: x1
  • Power Adapter: x1
  • Charging Cable: x1
  • Filter Components: x5

Warranty Periods

One year from the date of original purchase.

Models: IR-200 Infrared and Heated Diode, IR-200, Infrared and Heated Diode, Heated Diode

PDF preview unavailable. Download the PDF instead.

91z iEZXwoL Adobe PDF library 15.00 Adobe Illustrator 24.0 (Windows)

Related Documents

Preview Elitech WJL-6000S Corona Detector User Manual
User manual for the Elitech WJL-6000S Corona Detector, providing detailed instructions on operation, detection, troubleshooting, and maintenance for refrigerant leak detection in various systems.
Preview Elitech ILD Series Infrared Refrigerant Leak Detector User Manual
Comprehensive user manual for the Elitech ILD series infrared refrigerant leak detectors (ILD-100, ILD-200, ILD-300), covering specifications, operation, maintenance, and features. Learn how to effectively detect refrigerant leaks with this advanced device.
Preview Elitech LD-100 Heated Diode Refrigerant Leak Detector User Manual
User manual for the Elitech LD-100 Heated Diode Refrigerant Leak Detector, detailing its features, operation, and maintenance.
Preview Elitech MS-100 Digital Manifold: User Manual and Specifications
Comprehensive guide to the Elitech MS-100 digital manifold, covering its features, technical specifications, operation, safety instructions, and troubleshooting. Learn how to use the device for pressure and temperature measurements, leak tests, vacuum processes, and data logging with the Elitech Tools app.
Preview Elitech MS Series Digital Manifold Gauge User Manual
User manual for the Elitech MS Series digital manifold gauge, covering product description, general overview, button functions, specifications, quick start guide, operation steps, intelligent applications, and maintenance.
Preview Elitech LMC-310 Wireless Electronic Refrigerant Charging Scale User Manual
User manual for the Elitech LMC-310 Wireless Electronic Refrigerant Charging Scale. This guide provides detailed instructions on operation, specifications, and features of the LMC-310 scale.
Preview Elitech MS-800 Series Digital Manifold Gauge User Manual & Specifications
Comprehensive user manual for the Elitech MS-800 Series digital manifold instrument, covering product introduction, safety guidelines, environmental protection, detailed specifications, and quick operation guides for pressure and temperature measurements, hold pressure tests, and refrigerant charging for HVAC and refrigeration systems.
Preview Elitech RCW-600 WiFi User Manual
User manual for the Elitech RCW-600 WiFi, a two-channel temperature monitor based on IoT technology. Learn about its features, technical parameters, appearance, installation, operation, and WiFi configuration.