Remote Controller Owner's Manual
IMPORTANT NOTE
Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.
Remote Controller Specifications
Model | RG10A(D2S)/BGEF, RG10A(D2S)/BGEFU1, RG10A1(D2S)/BGEF, RG10A2(D2S)/BGEFU1, RG10A2(D2S)/BGCEFU1, RG10A2(D2S)/BGCEF, RG10A10(D2S)/BGEF, RG10B(D2)/BGEF, RG10B1(D2)/BGEF, RG10B2(D2)/BGCEF, RG10B10(D2)/BGEF, RG10B10(D2)/BGCEF, RG10Y1(D2)/BGEF, RG10Y2(D2S)/BGEF |
---|---|
Rated Voltage | 3.0 V (Dry batteries R03/LR03×2) |
Signal Receiving Range | 8 m |
Environment | -5°C ~ 60°C (23°F ~ 140°F) |
NOTE: For models of RG10Y1 (D2)/BGEF, RG10Y2(D2S)/BGEF, if the unit is turned off under COOL, AUTO or DRY mode with the set temperature less than 24°C, the set temperature will be automatically set to 24°C when you turn on the unit again. If the unit is turned off under HEAT mode with the set temperature more than 24°C, the set temperature will be automatically set to 24°C when you turn on the unit again.
Quick Start Guide
Follow these steps for basic operation:
- Fit Batteries: Ensure batteries are correctly inserted into the remote control.
- Select Mode: Press the 'Mode' button to cycle through AUTO, COOL, DRY, HEAT, and FAN modes.
- Select Temperature: Use the UP (⬆) and DOWN (⬇) arrow buttons to set the desired temperature.
- Select Fan Speed: Use the fan speed buttons to choose your preferred fan speed.
- Point Remote Toward Unit: Ensure the remote is pointed directly at the air conditioning unit.
- Press Power Button: Press the ON/OFF (⏻) button to turn the unit on or off.
NOT SURE WHAT A FUNCTION DOES? Refer to the 'How to Use Basic Functions' and 'How to Use Advanced Functions' sections of this manual for a detailed description.
SPECIAL NOTE:
- Button designs on your unit may differ slightly from the examples shown.
- If the indoor unit does not have a particular function, pressing that function's button on the remote control will have no effect.
- When there are wide differences between the "Remote Controller Manual" and "USER'S MANUAL" on function description, the description of "USER'S MANUAL" shall prevail.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries. Put the batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
BATTERY NOTES: For optimum product performance:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you do not plan on using the device for more than 2 months.
BATTERY DISPOSAL: Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL:
- The remote control must be used within 8 meters of the unit.
- The unit will beep when the remote signal is received.
- Curtains, other materials, and direct sunlight can interfere with the infrared signal receiver.
- Remove batteries if the remote will not be used for more than 2 months.
NOTES FOR USING REMOTE CONTROL: The device could comply with the local national regulations.
- In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
- In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment.
Buttons and Functions
Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the 'How to Use Basic Functions' section of this manual.
ON/OFF (⏻)
Turns the unit on or off.
TEMP ⬆ / ⬇
Increases or decreases the temperature in 1°C (1°F) increments. Maximum temperature is 30°C (86°F). Minimum temperature is 16°C (60°F). Pressing both TEMP ⬆ and ⬇ buttons simultaneously for 3 seconds will alternate the temperature display between °C and °F.
SET
Scrolls through operation functions. The selected symbol will flash on the display area; press the OK button to confirm. Functions include: Breeze Away (?️), Sleep (?), Follow Me (?), AP mode (?).
FAN SPEED (?)
Selects fan speeds in the following order: AUTO ➔ LOW ➔ MED ➔ HIGH. Holding this button down for 2 seconds activates the Silence feature (some units). You can also press the TEMP ⬆ or ⬇ button to increase/decrease the fan speed in 1% increments.
SWING (↔️)
Starts and stops the horizontal louver movement. Hold down for 2 seconds to initiate the vertical louver auto swing feature (some units).
MODE (?)
Scrolls through operation modes: AUTO ➔ COOL ➔ DRY ➔ HEAT ➔ FAN. Note: HEAT mode is not supported by cooling-only appliances.
ECO/GEAR (?)
Press this button to enter the energy-efficient mode in a sequence: ECO ➔ GEAR (75%) ➔ GEAR (50%) ➔ Previous setting mode ➔ ECO. This function is only available under COOL mode.
OK (✔️)
Used to confirm the selected functions.
TIMER (?)
Set timer to turn the unit on or off.
FRESH (?)
Used to start/stop the Fresh feature (some units).
CLEAN (?)
Used to start/stop the Self Clean or Active Clean function (model dependent). Please refer to the USER'S OPERATION & INSTALLATION MANUAL.
LED (?)
Turns the indoor unit's LED display and air conditioner buzzer on and off (model dependent), creating a comfortable and quiet environment.
TURBO (?)
Enables the unit to reach the preset temperature in the shortest possible time.
SLEEP (?)
Saves energy during sleeping hours. Not available in FAN or DRY mode.
SHORTCUT (?)
Used to restore the current settings or resume previous settings. Pressing for more than 2 seconds restores the current operation settings.
FP function
For heat pump air conditioners only. Operates at high fan speed with temperature automatically set to 8°C/46°F. Activate by pressing the FAN button twice within one second under HEAT Mode with specific temperature settings (refer to manual for models). Can be canceled by pressing ON/OFF, Sleep, Mode, Fan, or Temp buttons.
LOCK function (?)
Activate by pressing Clean and Turbo buttons simultaneously for over 5 seconds. All buttons become unresponsive except for Clean and Turbo, which can disable the lock when pressed together again for 2 seconds.
Remote Screen Indicators
Information is displayed when the remote controller is powered up. The display window shows relative function signs during actual operation.
- Transmission Indicator (?): Lights up when the remote sends a signal to the unit.
- TIMER ON/OFF Display (?): Shows timer settings.
- Silence feature display (?): Indicates when the silence feature is active.
- MODE display (?): Shows the current mode (AUTO, COOL, DRY, HEAT, FAN).
- ECO display (?): Shows when ECO feature is activated.
- GEAR display (⚙️): Shows when GEAR feature is activated.
- LOCK display (?): Shows when LOCK feature is activated.
- FAN SPEED display (?): Displays selected fan speed (e.g., 1%, 2%-20%, etc.). AUTO fan speed cannot be adjusted in AUTO or DRY mode.
- Temperature/Fan Speed display: Displays the set temperature or timer setting.
- Horizontal louver swing display (➡️⬅️): Indicates horizontal louver swing.
- Vertical louver auto swing display (⬆️⬇️): Indicates vertical louver auto swing.
- TURBO mode display (?): Indicates when TURBO mode is active.
- A: Not available for this unit.
- B: This unit.
Note: All indicators shown are for presentation purposes. Only relative function signs are shown during actual operation.
How to Use Basic Functions
ATTENTION: Before operation, please ensure the unit is plugged in and power is available.
AUTO Mode
- Select AUTO mode.
- Set your desired temperature.
- Turn on the air conditioner.
NOTE: In AUTO mode, the unit automatically selects COOL, FAN, or HEAT based on the set temperature. Fan speed cannot be set in AUTO mode.
COOL or HEAT Mode
- Select COOL/HEAT mode.
- Set the temperature.
- Set the fan speed.
- Turn on the air conditioner.
DRY Mode
- Select DRY mode.
- Set your desired temperature.
- Turn on the air conditioner.
NOTE: In DRY mode, fan speed is automatically controlled and cannot be set.
FAN Mode
- Select FAN mode.
- Set the fan speed.
- Turn on the air conditioner.
NOTE: In FAN mode, you cannot set the temperature, so no temperature displays on the remote screen.
Setting the TIMER
Use the TIMER button to set the amount of time after which the unit will automatically turn on or off.
TIMER ON setting
Press the TIMER button to initiate the ON time sequence. Use the Temp. up or down buttons to set the desired time to turn on the unit.
TIMER OFF setting
Press the TIMER button to initiate the OFF time sequence. Use the Temp. up or down buttons to set the desired time to turn off the unit.
NOTE:
- When setting TIMER ON or OFF, the time increases in 30-minute increments up to 10 hours. After 10 hours, it increases in 1-hour increments up to 24 hours. The timer resets to 0.0 after 24 hours.
- Cancel either function by setting its timer to 0.0 h.
TIMER ON & OFF setting (example)
The time periods set for both functions refer to hours after the current time. For example, if the current time is 1:00 PM, setting the timer ON for 2.5 hours means the unit will turn on at 3:30 PM. Setting the timer OFF for 5 hours means the unit will turn off at 6:00 PM.
How to Use Advanced Functions
Swing function (↔️)
Press the Swing button. The horizontal louver will swing up and down automatically. Press again to stop. Holding the button for more than 2 seconds activates the vertical louver auto swing feature (model dependent).
Airflow direction
By repeatedly pressing the SWING button, you can set five different airflow directions. The louver moves to a specific range with each press. Press until the desired direction is reached.
NOTE: When the unit is off, press and hold MODE and SWING buttons together for one second to open the louver for cleaning. Press and hold them again for one second to reset the louver (model dependent).
LED DISPLAY (?)
Press the LED button to turn the indoor unit's display and buzzer on or off (model dependent).
Press and hold the LED button for more than 5 seconds (some units) to display the actual room temperature. Pressing again for more than 5 seconds reverts to displaying the set temperature.
ECO/GEAR function (?)
Press this button to cycle through energy-efficient modes: ECO ➔ GEAR (75%) ➔ GEAR (50%) ➔ Previous setting mode ➔ ECO. This function is only available under COOL mode.
- ECO operation: Under cooling mode, pressing ECO adjusts the temperature to 24°C/75°F and sets fan speed to Auto to save energy (if set temperature is below 24°C/75°F). If the set temperature is above 24°C/75°F, only the fan speed changes to Auto.
- GEAR operation: Allows setting electrical energy consumption to 75% or 50%. The display alternates between energy consumption and set temperature.
NOTE: Pressing the ECO/GEAR button, changing the mode, or adjusting the set temperature below 24°C/75°F will stop ECO operation. If cooling is insufficient, press the ECO button again to stop it.
SHORTCUT function (?)
Press the SHORTCUT button (some units). When the remote controller is on, this function reverts to previous settings (mode, temperature, fan speed, sleep). Pressing for more than 2 seconds restores current operation settings.
Silence function (?)
Press and hold the Fan button for more than 2 seconds to activate/disable the Silence function (some units). This may result in reduced cooling/heating capacity due to low-frequency compressor operation. Pressing ON/OFF, Mode, Sleep, Turbo, or Clean buttons cancels this function.
FP function
This function is for heat pump air conditioners only. The unit operates at high fan speed with the temperature automatically set to 8°C/46°F. It is activated by pressing the FAN button twice within one second under HEAT Mode with specific temperature settings (refer to manual for models). This function can be canceled by pressing ON/OFF, Sleep, Mode, Fan, or Temp buttons.
LOCK function (?)
Activate by pressing the Clean and Turbo buttons simultaneously for over 5 seconds. All buttons become unresponsive except for Clean and Turbo, which can disable the lock when pressed together again for 2 seconds.
SET function
Press the SET button to enter function settings. Use SET, TEMP ⬇, or TEMP ⬆ to select a function; the symbol will flash. Press OK to confirm. To cancel, repeat the procedure. Functions include: Breeze Away (?️), Fresh (?), Sleep (?), Follow Me (?), AP mode (?).
- Breeze Away function (?️): Avoids direct airflow for comfort. Available in COOL, FAN, and DRY modes only.
- FRESH function (?): Activates the ion generator to help purify the air.
- Sleep function (?): Decreases energy use during sleep. Not available in FAN or DRY mode.
- Follow me function (?): The remote measures ambient temperature and sends it to the unit for optimized comfort. Press and hold the Turbo button for seven seconds to start/stop the memory feature. If the memory feature is activated, "On" displays for 3 seconds. If stopped, "OF" displays. This function is not canceled by ON/OFF button presses or power failures when activated.
- AP function (?): Used for wireless network configuration. For some units, press the LED button seven times within 10 seconds to enter AP mode.
Technical Requirements
Size: A5, Large size 80g double-sided paper binding, black and white.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
Model: CR2756-RG10(D2S)
Document ID: 16117000A37345
Date: 2021.05.08