MASTECH MAS830B Digital Multimeter Quick Start Guide
This guide provides essential information for the safe and effective use of the MASTECH MAS830B Digital Multimeter.
Safety Precautions
General Safety: Special attention should be paid when using this test and measurement instrument, as improper usage may cause electric shock and damage to the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling test probes and crocodile clips, keep your fingers behind the physical guard.
- Examine the measuring test leads before use. If any part of the insulation is deteriorated, replace them with proper functional test leads.
- Connect the common test lead before the live test lead, and remove the live test lead before the common test lead.
- Before measuring current, ensure the instrument has available fuses and disconnect the power supply to the circuit being tested.
- Remove batteries if the device is not used for an extended period or if stored in temperatures above 45°C to prevent battery leakage damage.
Specifications
Specifications are subject to change without notification.
Range | Resolution | Accuracy |
---|---|---|
V~ 200V/600V | 0.1V/1V | ±(1.2%+10) |
V= 200mV/2V/20V/200V | 0.1mV/1mV/10mV/0.1V | ±(0.5%+3) |
600V | 1V | ±(0.8%+5) |
A= 20mA | 20μA | ±(1.0%+3) |
200mA | 0.1μA/1μA | ±(1.0%+3) |
10A | 10μA | ±(1.0%+5) |
Ω 200Ω | 0.1Ω | ±(0.8%+5) |
2ΚΩ/20ΚΩ/200ΚΩ | 10/100/0.1ΚΩ | ±(0.8%+2) |
2ΜΩ | 1ΚΩ | ±(1.0%+5) |
Measurement Category: CAT II 600V
Warranty: 1 YEAR LIMITED WARRANTY
Basic Measurement Procedures
The following diagrams illustrate basic measurement procedures: Procedure: Diagram shows connecting leads to the multimeter and then to a DC voltage source, displaying '12.56'. Procedure: Diagram shows connecting leads to the multimeter and then to an AC voltage source, displaying '220'. Procedure: Diagram shows connecting leads in series with a circuit, displaying '2.53'. Procedure: Diagram shows connecting leads to a resistor, displaying '1005'. Procedure: Diagram shows connecting leads to a low voltage DC source, displaying '0.6'. Procedure: Diagram shows a transistor being inserted into the hFE socket, displaying '100'.DC Voltage (V=) Measurement
AC Voltage (V~) Measurement
DC Current (A=) Measurement
Resistance (Ω) Measurement
DC Voltage (V=) Measurement (Low Voltage)
Transistor hFE Measurement
Company Information
EMEA: MGL EUMAN S.L., C/ Picu Castiellu, Parcelas i1-i4 33163, Argame Morcín, Asturias, Spain. Tel: +34 985-08-18-70, Email: cs.emea@mgl-intl.com
USA: MGL AMERICA, INC., 2810 Coliseum Centre Drive, Ste. 100 Charlotte, North Carolina 28217 USA. Tel: +1 833-533-5899, Email: cs.na@mgl-intl.com
United Kingdom: MGL GROUP U.K. LIMITED, 14 Weller St, London, SE1 1QU, UK. Tel: +34 985-08-18-70, Email: cs.uk@mgl-intl.com
Mexico & LATAM: MGL LATAM S.A DE CV, Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F. Tel: +1 833-533-5899, Email: cs.latam@mgl-intl.com
APAC: MGL APPA Corporation, Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan. Tel: +886 2-2508-0877, Email: cs.apac@mgl-intl.com
SKU Number: MAS830BCBGLO
Document Revision: May 2021 Rev. 1