Installation and Safety Instructions
Safety Notes
- Never work when voltage is present on the luminaire.
- Installation must be performed by a professional installer in compliance with electrical installation standards and regulations.
- Risk of electrostatic discharges (ESD Norm). Handle with necessary precautions.
- Please observe the notes and mounting steps described.
Maintenance Instructions
- Do not use chemicals or abrasive products to clean the fixture.
- Keep these instructions for removal or subsequent maintenance. Additional information about RESISTEX luminaires is available on the website www.resistex-sa.com.
- RESISTEX cannot be held responsible for any misuse of the product.
Mounting and Installation
The SKORE luminaire requires professional installation. Follow these steps carefully:
Installation Steps
- Step 1 (01): Attach suspension elements using 4 screws to the ceiling or mounting surface.
- Step 2 (02): Mount the luminaire body. Attach the luminaire to the suspension elements using 4 screws.
- Step 3 (03): Connect the wiring. Ensure power is OFF.
- Power: Connect mains supply wires (L1, L2, L3, N, E) to the corresponding terminals.
- DALI Control: Connect DALI control wires to the 'DA' terminals.
- Dimmable Control: Connect dimming control wires to the 'Dim+' and 'Dim-' terminals.
- Wire Gauge: Use wires with a cross-section of 1.5-2.5 mm².
- Max Cable Length: Maximum recommended cable length for control signals is 12 meters.
- Step 4 (04): Secure the cover. Close the luminaire cover and fasten with 2 screws.
- Step 5 (05): Adjust the angle. The luminaire offers adjustable angles. Refer to the diagram for specific settings (e.g., 15°, 30°, 45°, 60°) and their corresponding values.
- Step 6 (06): Final placement. Ensure the luminaire is securely mounted.
- Step 7 (07): Final wiring check. Verify all connections are secure before powering on.
Diagram Descriptions
Suspension and Angle Adjustment Diagram: This diagram illustrates the suspension system and how the luminaire is attached. It highlights the adjustable angle mechanism, showing different tilt settings (15°, 30°, 45°, 60°) and their associated adjustment values.
Wiring Terminal Block Diagram: This diagram details the internal wiring connections. It shows terminals for mains power (L1, L2, L3, N, E) and control signals (DA for DALI, Dim+ and Dim- for dimming). It specifies wire gauge (1.5-2.5 mm²) and maximum control cable length (12 meters).
Product Features and Specifications
- Product Name: SKORE
- Brand: Resistex
- LED: Integrated, replaceable by a professional.
- Driver: Replaceable by a professional.
- Angle Adjustment: Yes, multiple settings available.
- Ingress Protection: IP20
- Impact Resistance: IK10
- Warranty: 5 Years
- Certifications: RoHS, CE
- Voltage: 230V
- Control Compatibility: DALI, Dimmable