Resistex Noclip Installation Guide

Product Information

Model: Noclip

Brand: Resistex

Version: V3.1 - 03.24

Safety Instructions

⚠️ Never work when voltage is present on the luminaire.

⚠️ The installation must be performed by a professional installer in compliance with the standards and regulations relating to electrical installations.

⚠️ Risk of electrostatic discharges. (ESD Norm). Handle with precautions.

⚠️ Please observe the notes and steps described in the mounting instructions.

Maintenance Instructions

❗ Do not use chemicals or abrasives products to clean the fixture.

❗ Keep these instructions for dismantling or future maintenance. Additional information about RESISTEX luminaires is available on the website www.resistex-sa.com.

❗ RESISTEX cannot be responsible for any misuse of the product.

Installation Steps

Step 1: Prepare Luminaire Body

Attach a mounting bracket to the main body of the luminaire. This involves inserting a screw and tightening it.

Diagram shows a screw being inserted into a bracket, which is then attached to the luminaire body.

Step 2: Mount to Surface

Insert a wall plug (1) into a pre-drilled hole in the mounting surface. Then, attach the luminaire body (2) to the wall plug using a screw.

Diagram shows a wall plug being inserted into a hole, followed by the luminaire body being screwed onto it.

Step 3: Access Electrical Compartment

Open the electrical compartment of the luminaire. This typically involves releasing a latch or cover.

Diagram shows the luminaire body with a cover being opened to reveal the internal wiring and driver compartment.

Step 4: Connect Power Cable

Connect the power cable (HO5RN-F U-1000 R2V) to the terminal block inside the electrical compartment. The cable has conductors labeled L (Line), N (Neutral), and E (Earth).

Diagram shows a cable with L, N, E markings being connected to a terminal block.

Step 5: Connect Driver/Module

Connect the internal wiring of the luminaire to the driver or control module. The diagram shows three connection options: ON/OFF (HF), BP (Ballast Push), and DALI (Digital Addressable Lighting Interface). Each option has specific terminals for L, N, E, and control signals (e.g., DA/N, DA/L).

Diagram illustrates three distinct wiring configurations for controlling the luminaire: basic ON/OFF, a ballast interface (BP), and a DALI system. Terminals for Line, Neutral, Earth, and control signals are shown for each.

Step 6: Install Driver/Module

Insert the connected driver or control module into its designated space within the luminaire body.

Diagram shows the driver/module being placed into the luminaire housing.

Step 7: Close Compartment

Close and secure the electrical compartment cover.

Diagram shows the electrical compartment cover being closed.

Step 8: Final Assembly and Cable Length

Insert the light tube into the luminaire body. The diagram also specifies cable length (L) requirements for different luminaire sizes: 1200mm luminaires require 700mm < L < 1000mm, and 1500mm luminaires require 900mm < L < 1200mm. It shows two mounting points ([Ø6mm]) for securing the luminaire.

Diagram shows the light tube being fitted into the luminaire. It also provides guidelines for the length of the power cable (L) relative to the luminaire length, with specific ranges for 1200mm and 1500mm models. Two mounting holes ([Ø6mm]) are indicated.

Models: Noclip Color LED Board, Noclip, Color LED Board, LED Board, Board

File Info : application/pdf, 2 Pages, 796.60KB

PDF preview unavailable. Download the PDF instead.

605201 NOT1

References

GPL Ghostscript 9.53.3

Related Documents

PreviewResistex Noclip LED Lighting Installation Guide
Detailed installation instructions for the Resistex Noclip LED lighting fixture. Covers safety precautions, mounting procedures, and electrical connections for ON/OFF, HF, and DALI systems. Includes product specifications and certifications.
PreviewResistex 605201 NOCLIP LED Luminaire - Technical Specifications and Features
Detailed technical specifications for the Resistex 605201 NOCLIP industrial LED luminaire, including photometric data, mechanical characteristics, electrical specifications, and normative certifications. Features 3340lm output, 4000K color temperature, and IP65 rating.
PreviewRESISTEX HUBO Lighting Fixture Installation Guide
Comprehensive installation instructions for the RESISTEX HUBO lighting fixture, including safety guidelines, maintenance tips, and step-by-step assembly procedures. Features IP65, IK10 ratings and CE marking.
PreviewResistex AIKLA Installation Guide: Safety, Mounting, and Maintenance
Comprehensive installation guide for the Resistex AIKLA lighting fixture. Includes safety precautions, mounting instructions for wall and post applications, and maintenance advice. Ensure correct electrical installation for optimal performance and safety.
PreviewResistex KOMET HF Version Installation Instructions
Comprehensive installation guide for the Resistex KOMET HF version lighting fixture, including safety notes, maintenance procedures, and step-by-step mounting instructions.
PreviewResistex AIKLA Installation Guide
Detailed installation instructions and safety guidelines for the Resistex AIKLA lighting fixture. Includes technical specifications and mounting procedures for wall and post installations.
PreviewResistex Stairled Luminaire Installation and Safety Guide
Comprehensive installation instructions and safety guidelines for the Resistex Stairled luminaire, detailing dimensions, mounting procedures, maintenance, and product features.
PreviewResistex Hemeria Luminaire Installation Guide
Detailed installation and safety instructions for the Resistex Hemeria lighting fixture, including mounting, wiring, and maintenance guidelines.