MASTECH MS6818 Advanced Cable Locator
Quick Start Guide
SKU Number: MS6818CBGLO
1 YEAR LIMITED WARRANTY
Safety Precautions
Special attention should be paid when using the test and measurement instrument because improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
- Examine the measuring test leads (if present) before use. Any element of which the insulation is deteriorated (even partially), replace them with proper functional test leads.
- Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
- Before measuring current, make sure the instrument fuses are available and disconnect the power supply to the circuit test.
- Remove the batteries if the device is not used for an extended period of time, or if stored in temperatures above 45 °C. If the batteries are not removed, battery leakage can damage the device.
Technical Parameters of Transmitter
Parameter | Value |
---|---|
Output Signal | 125kHz |
External Voltage | DC12~400V AC12~400V (50~60Hz) ±2.5% |
Fuse | F0.5A 1000V |
MIN Current | about 31mA |
MAX Current | about 115mA |
In Work | 0~40°C, with MAX relative humidity of 80% |
In Storage | -20~60°C, with MAX relative humidity of 80% |
Altitude | <2000m |
Technical Parameters of Receiver
Parameter | Value |
---|---|
Depth of Tracking | The Depth of Tracking Depends on the Material and Specific Applications |
Cable Locating Mode | Single pole application: about 0~2m Dual pole application: about 0~0.5m Single loop line: Up to 2.5m |
MIN Current | about 32mA |
MAX Current | about 89mA |
In Work | 0~40°C, with MAX relative humidity of 80% |
In Storage | -20~60°C, with MAX relative humidity of 80% |
Altitude | <2000m |
Basic Operation
Refer to the diagrams for detailed operational steps. The diagrams illustrate:
- Battery installation and connection.
- Transmitter connection to AC and DC sources.
- Receiver usage for tracing cables of different diameters and depths.
- Using the LEVEL and CODE functions on the receiver.
- Manual mode operation.
Company Information
EMEA: MGL EUMAN S.L., C/ Picu Castiellu, Parcelas i1-i4 33163, Argame Morcín, Asturias, Spain. Tel: +34 985-08-18-70, Email: cs.emea@mgl-intl.com
USA: MGL AMERICA, INC., 2810 Coliseum Centre Drive, Ste. 100 Charlotte, North Carolina 28217 USA. Tel: +1 833-533-5899, Email: cs.na@mgl-intl.com
UNITED KINGDOM: MGL GROUP U.K. LIMITED, 14 Weller St, London, SE1 1QU, UK. Tel: +34 985-08-18-70, Email: cs.uk@mgl-intl.com
MEXICO & LATAM: MGL LATAM S.A DE CV, Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F. Tel: +1 833-533-5899, Email: cs.latam@mgl-intl.com
APAC: MGL APPA Corporation, Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan. Tel: +886 2-2508-0877, Email: cs.apac@mgl-intl.com