Minoston MS12ZS Smart On/Off Toggle Switch Manual
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
(Original document also contains French compliance statements: DECLARATION DE CONFORMITE D'INDUSTRIE CANADA)
Warranty
Evalogik Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from state to state. If the unit should prove defective within the warranty period.
Specifications
Model | MS12ZS |
---|---|
Power | 120 VAC, 60 Hz. |
Signal (Frequency) | 908.42 MHz |
Maximum load for outlet (Resistive) | 15A, 960W |
Maximum load for Z-Wave™ controlled outlet | 600W Incandescent, 1/2 HP Motor or 600W Resistive |
Range | Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave™ receiver module. |
Operating Temperature Range | 32-104° F (0-40° C) |
Specifications subject to change without notice due to continuing product improvement.
Website: www.nie-tech.com
Warning
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES: EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO AN UNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE THE FOLLOWING:
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction
This product can be operated in any Z-Wave network with other Z-Wave Plus™ certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination. The MS12ZS is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave Plus™ Controller must be used in order to fully utilize the product. The Device Type of the MS12ZS is on/off power switch. The Role Type of the MS12ZS is Always On Slave Role Type.
Key Features
- Remote ON/OFF control via the Z-Wave™ controller
- Manual ON/OFF control with the front panel push button
- Support Association Group and Auto Report switch status
- Support firmware upgrades via Over-the-air (need Gateways support)
- Support Scenes
Product Overview
The switch has the following labeled parts:
- A: Up Push button
- B: Down Push button
- C: Load1 (Black wire terminal)
- D: Line (Black wire terminal) - Line in
- E: Neutral (White wire terminal) - Neutral in
- F: 3-way (RED wire terminal)
MS12ZS Installation Wiring Diagram Description
The wiring diagram indicates the following connections:
- LINE (Hot) - Black wire: Connects to the 'Lin' terminal (D) on the switch.
- NEUTRAL - White wire: Connects to the 'Nin' terminal (E) on the switch.
- LOAD - Black wire: Connects to the 'Load1' terminal (C) on the switch.
- GROUND - Green/Bare wire: Connects to the ground screw on the switch.
- TRAVELER - Red/Other wire: Connects to the '3-way' terminal (F) on the switch (used in 3-way installations).
Note: Terminals A and B are the Up and Down push buttons respectively.
Key Function Description
- Function 1: Press the up or down button to turn the output ON or OFF.
- Function 2: Quickly press the upper paddle 3 times: inclusion (only if switch is not included in network). Quickly press the lower paddle 3 times: exclusion.
- Function 3: Quickly press the upper paddle 6 times: change Status LED Configuration.
- Function 4: Press and hold the lower paddle for 10 seconds, then the LED starts blinking. Release the paddle and within 2 seconds, click the lower paddle 5 times. (Node: Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
- Function 5: Tap A (1x/2x/3x/4x/5x/Hold/Release): Activate the scene.
- Function 6: Tap B (1x/2x/3x/4x/5x/Hold/Release): Activate the scene.
Adding Your Device To A Hub
The device supports two methods of inclusion: Network Wide Inclusion or SmartStart. When using a Z-Wave Plus™ certified controller, choose one of these methods.
Network Wide Inclusion To A Z-Wave™ Network
- Refer to your primary controller instructions to process the inclusion/exclusion setup procedure.
- When prompted by your primary controller, click the Up or Down button three times in one second.
SmartStart
The device is compatible with SmartStart. SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No further action is required, and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.
[QR Code Description: A QR code containing device-specific information (DSK) for SmartStart inclusion is located on the product or its packaging.]
Z-Wave™ Protocol Command Class Node Info
- COMMAND_CLASS_ZWAVEPLUS_INFO_V2
- COMMAND_CLASS_SWITCH_BINARY_V2
- COMMAND_CLASS_CONFIGURATION_V4
- COMMAND_CLASS_CENTRAL_SCENE_V3
- COMMAND_CLASS_ASSOCIATION_V3
- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
- COMMAND_CLASS_TRANSPORT_SERVICE_V2
- COMMAND_CLASS_VERSION_V3
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_INDICATOR_V3
- COMMAND_CLASS_POWERLEVEL_V1
- COMMAND_CLASS_SECURITY_2
- COMMAND_CLASS_SUPERVISION_V1
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
The following Command Classes are also supported with Security S2:
- COMMAND_CLASS_VERSION_V2
- COMMAND_CLASS_SWITCH_BINARY_V2
- COMMAND_CLASS_CONFIGURATION_V4
- COMMAND_CLASS_CENTRAL_SCENE_V3
- COMMAND_CLASS_ASSOCIATION_V3
- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
- COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_INDICATOR_V3
- COMMAND_CLASS_POWERLEVEL_V1
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change settings of the corresponding functionality.
Paramter No. | Size | Default Value | Description |
---|---|---|---|
1 (0x01) | 1 Byte | 00 | Locally Button Function: Value 00: Up Button ON, Down Button OFF Value 01: Up Button OFF, Down Button ON Value 02: Up Button ON/OFF, Down Button ON/OFF |
2 (0x02) | 1 Byte | 00 | Status LED Configuration: Value 00: Output and the LED are in different states. Value 01: Output and the LED are in the same state. Value 02: LED Always OFF Value 03: LED Always ON |
3 (0x03) | 4 Bytes | 0 (minutes) | Auto Turn-Off Timer: Values: 0 - 65535 (minutes) |
5 (0x05) | 4 Bytes | 0 (minutes) | Auto Turn-Off Timer: Values: 0 - 65535 (minutes) |
8 (0x08) | 1 Byte | 02 | Restores state after power failure: Value 00: Output OFF. Value 01: Output ON. Value 02 (default): The state before a power outage. |
11 (0x0B) | 1 Byte | 1 | Enable or Disable Output Control: Value 0: Disable local button and external switch control, enable Z-Wave™ control. Value 1: Enable local button and external switch control, enable Z-Wave™ control. Value 2: Disable local button and external switch control. |
12 (0x0C) | 1 Byte | 0 | External switch type: Value 0: Toggle switch (device changes status when switch changes status). Value 01: Momentary switch. Value 02: Electronic add-on switch. |
13 (0x0D) | 1 Byte | 0 | Behavior when Output control disabled: Value 0: Report on/off status and change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). Value 01: Do not report on/off status or change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). |
14 (0x0E) | 1 Byte | 1 | LED Indicator Color: Value 0: White Value 01: Blue Value 02: Green Value 03: Red |
15 (0x0F) | 1 Byte | 1 | LED Indicator Brightness: Value 00: Bright (100%) Value 01: Medium (60%) Value 02: Low (30%) |
16 (0x10) | 1 Byte | 1 | Association reports: Value 00: Z-Wave™ control: Binary switch report, Manual control: Basic set report. Value 01: Z-Wave™ control: Binary switch report, Manual control: Binary switch report. |
Support for Association Groups
MS12ZS supports 3 association groups. Group 1 supports 1 node ID, Group 2 and Group 3 support a maximum of 5 node IDs.
- Association group_1: Z-Wave™ Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MS12ZS Status change report. MS12ZS will trigger AUTO report function if the Switch status had been changed (e.g., Switch Binary Report/Basic Report/Central Scene Notification/ Device Reset Locally Notification). - Association group_2: Basic set command
When the output of the MS12ZS is changed, On (0xFF) or Off (0x00). The MS12ZS will automatically send out a related basic set command (On (0xFF) or Off (0x00)) to its associated group. - Association group_3: Basic set command
When the output of the MS12ZS is changed, On (0xFF) or Off (0x00). The MS12ZS will automatically send out a related basic set command (On (0xFF) or Off (0x00)) to its associated group.
Restoring Factory Defaults
The MS12ZS can be removed from the network and restored to factory settings. All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset: Press and hold the lower paddle for 10 seconds, then the LED starts blinking. Release the paddle and within 2 seconds, click the lower paddle 5 times.
Remark: All the setting and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.