MS-6115 Multifunction Power Meter Instructions
WARNING!
Do not plug two or more meters together!
Indoor use only!
Do not position the energy meter so that it is difficult to disconnect it from the supply!
IMPORTANT
Do not plug in an appliance where the load exceeds 10 Amp. Always ensure the plug of any appliance is fully inserted into the meter outlet. If cleaning of the meter is required, remove from mains power and wipe meter with a dry cloth.
KEYBOARD DEFINITION
- MASTER CLEAR: Clear all data in memory including current time and all programs.
- UP: Set current time, price, price programs combined with buttons SET; exchange 12-24 hour mode during clock display state.
- SET: Set current time, price, price programs combined with buttons UP.
- FUNC: Exchange display state.
GENERAL FEATURES
- Display current clock.
- Display line voltage.
- Display line current.
- Display line power.
- Display and memory accumulative total electric quantity.
- Display and memory total on time and total electric charge.
- Display and memory total on time and total electric charge of price1.
- Display and memory total on time and total electric charge of price2.
- Display line frequency.
- Display power factor.
- Adjustable price / kWh
11 combinations of day or blocks of days available as follows:
- MO
- TU
- WE
- TH
- FR
- SA
- SU
- MO,TU, WE, TH, FR
- MO,TU, WE, TH, FR, SA
- SA, SU
- MO, TU, WE, TH, FR, SA, SU
BATTERY
Insert 3 pcs LR44/AG13 batteries according to the correct direction indication. Close the battery cover. Press the MASTER CLEAR button after inserting the battery. The power meter is now ready to be set up for use.
Note: 1. The cover must be in place before use. 2. The battery must be taken out if not used for a long time.
THE DATA DISPLAY
Press FUNC button to cycle through data displays:
VOLT AC → AMP → WATT → KWh → TOTAL PRICE; TOTAL ON TIME → PRICE1 → PRICE2
- The meter will display current clock and line voltage, frequency if plugged in after battery insertion without any operation.
- Press FUNC button once to display current clock and line current, power factor.
- Press FUNC button again to display current clock and real power, power factor.
- Press FUNC button again to display current clock and accumulative KWh, power factor.
- Press FUNC button again to display total on time and total electric charge.
- Press FUNC button again to display total on time of price 1 and total electric charge of price 1.
- Press FUNC button again to display total on time of price 2 and total electric charge of price 2.
- Press FUNC button again to return to display current time and line voltage.
Press and hold FUNC button for 5 seconds to clear accumulative total electric quantity and total electric charge during display of total electric charge, total electric charge of price 1, or total electric charge of price 2.
LCD display: When total electric quantity or total electric charge overflows, "OVER" will flash at the same time.
SETTING CURRENT CLOCK
- Press FUNC button until the CLOCK displays in LCD.
- Press SET button once. The "WEEK DAY" will flash, entering SET mode. Use UP button to set the "WEEK DAY".
- Press SET button again. The "HOUR" will flash, "WEEK DAY" will stop flashing. Use UP button to set the "HOUR".
- Press SET button again. The "MINUTE" will flash, "HOUR" will stop flashing. Use UP button to set the "MINUTE".
- Press SET button again to return to CLOCK display mode.
- During CLOCK display, press UP button to switch between 12-hour and 24-hour modes.
To reset incorrect time, repeat the above steps.
After setting, plug the meter into a regular 240 Volts power outlet. Plug in an appliance and turn the mains power on. The meter will begin measuring consumption and detecting high-usage equipment.
SETTING PRICE OF COST/kWh
Press and hold FUNC button for 5 seconds while displaying voltage, current, or power.
Setting Price 1:
- Press SET button. The "SET" display appears, and the first digit of COST/kWh flashes. Use UP button to set.
- Press SET button again. The second digit flashes. Use UP button to set.
- Press SET button again. The third digit flashes. Use UP button to set.
- Press SET button again. The fourth digit flashes. Use UP button to set.
- Press SET button again. The radix point flashes. Use UP button to set.
- Press SET button again. The weekday flashes. Use UP button to set.
- Press SET button again. The hour of ON TIME flashes. Use UP button to set.
- Press SET button again. The minute of ON TIME flashes. Use UP button to set.
Setting Price 2:
Press FUNC button once after finishing Price 1 settings. Repeat the above steps to set Price 2.
STAND BY MODE
The LCD display will disappear without operation after AC power is off for 10 seconds. Press any key to wake the display.
SPECIFICATIONS
Parameter | Value |
---|---|
Power supply | 240V AC 50Hz |
Max. load | 10A, 2400W |
Measure voltage range | 200-276V AC |
Measure voltage accuracy | +/-1% |
Measure current range | 0.01-10A |
Measure current accuracy | +/-1% or +/-0.01 A |
Measure power range | 0.2W-2760W |
Measure power accuracy | +/-1% or +/-0.2W |
Accumulative electric quantity range | 0-9999.9kWh |
Measure frequency range | 45-65Hz |
Clock accuracy | +/- 1 minute per month |
Power cost | <0.5W |
Operating temperature | -10 °C to +40 °C |
Battery | 3x1.5V LR44/AG13 |
Battery life | About 3 months without AC power |
Distributed by
Electus Distribution Pty Ltd.
320 Victoria Road, Rydalmere, NSW 2116 Australia.
Phone: 1300 738 555
Facsimile: 1300 738 500
www.electusdistribution.com.au
Made in China
WARNING - KEEP BUTTON BATTERIES OUT OF REACH OF CHILDREN
⚠️ If swallowed, a lithium button battery can lead to serious or fatal injury in as little as 2 hours, due to chemical burns and potential perforation of the oesophagus.
All button batteries must be kept away from children regardless if they are new or used.
If you suspect your child has swallowed or inserted a button battery, immediately call the 24-hour Poisons Information Centre on 13 11 26 (Australia) or 0800 764 766 (New Zealand) for fast, expert advice.
If your child is having difficulty breathing, contact 000 (Australia) or 111 (New Zealand).
Dispose of used button batteries immediately and safely out of the reach of children. A battery can still be dangerous even when it can no longer operate the device.
As soon as you have finished using a button battery, put sticky tape around both sides of it. This will make it harder for children to swallow the button battery and avoid the risk of the battery catching fire.