EFace10 Installation Guide
How to Install the Device?
With Backplate:
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the Backplate on the wall using the wall mounting screws.
- Attach the device to the Backplate.
- Fasten it with a security screw.
Note: Features and parameters with $\star$ mark are not available in all devices.
With Back Cover $\star$:
Wall Mount
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the Back Cover on the wall using the wall mounting screws.
- Attach the device to the Back Cover.
- Fasten it with a security screw.
Desktop Placement
- Attach the Back Cover to the Device.
- Fasten it with a security screw.
Wiring Diagram
Power Connection:
Recommended AC Adapter:
- $12 \mathrm{~V} \pm 10 \%$, at least 1500 mA.
- To share the power with other devices, use an AC Adapter with higher current ratings.
Ethernet Connection:
Connect the device and computer software over an Ethernet cable. As shown in the example below:
IP address: 192.168.1.130
Subnet mask: 255.255.255.0
To configure the IP address: Click on [COMM.] > [Ethernet] > [IP Address], input the IP address and click on [OK].
Note: In LAN, the IP addresses of the server (PC) and the device must be in the same network segment when connecting to the ZKBioAccess IVS software.
Lock Relay Connection:
Device not sharing power with the lock:
The diagram shows a connection for an NC Lock with a DC12V power source and a FR107 diode.
Door Sensor, Exit Button & Auxiliary Input Connection:
The diagram illustrates connections for a Door Sensor, an Exit Button, and an Auxiliary Input, along with a Smoke Detector.