ZKTeco SpeedFace-V3L Installation Guide
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
How to Install the Device?
Installation Environment
Please refer to the following recommendations for installation.
- KEEP DISTANCE [distance icon]
- AVOID GLASS REFRACTION [refraction icon]
- AVOID DIRECT SUNLIGHT AND EXPOSURE [sun icon]
- KEEP EFFECTIVE DISTANCE 0.3-2.5m [distance icon]
Device Installation
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the backplate on the wall using wall mounting screws.
- Attach the device to the backplate.
- Fasten the device to the backplate with a security screw.
Diagram showing mounting steps with measurements (1.5m height).
Wiring Diagram
Power Connection
Diagram illustrating power connection with a 12V adapter.
Recommended AC Adapter:
- 12V ± 10%, at least 1500mA.
- To share the power with other devices, use an AC Adapter with higher current ratings.
Ethernet Connection
Connect the device and computer software over an Ethernet cable. As shown in the example below:
Diagram showing Ethernet connection between the device and a computer running ZKBio Access software.
Default IP address: 192.168.1.201, Subnet mask: 255.255.255.0
IP address: 192.168.1.130, Subnet mask: 255.255.255.0
Click on [COMM.] > [Ethernet] > [IP Address], input the IP address and click on [OK].
Note: In LAN, the IP addresses of the server (PC) and the device must be in the same network segment when connecting to the ZKBio Access software.
Wiegand Reader Connection
Diagram showing Wiegand reader connection to the Access Controller.
Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader separately, but cannot be connected to the gate and reader at the same time.
RS485 Connection
Diagram showing RS485 connection to a 485 Reader.
Door Sensor, Exit Button, Alarm & Auxiliary Connection
Diagram illustrating connections for Door Sensor, Exit Button, Smoke Detector, and Alarm.
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals. Take NC Lock as an example below:
1) Device not sharing power with the lock
Diagram showing NC Lock connection without sharing power, including polarity warning.
2) Device sharing power with the lock
Diagram showing NC Lock connection while sharing power.
Maximum 30V 3A input.
Download Center
Scan the QR Code to download the User Manual, Installation Guide and Quick Start Guide.