PRODUCT MANUAL

powerCON TRUE1

NAC3F-TRUE1-CG & NAC3M-TRUE1-CG

1 APPLICATION & SAFETY INSTRUCTION

IP 65, IP 66, & IP 67 RATED

APPLICATION:

  • The powerCON TRUE1 system is certified as appliance couplers with breaking capacity according to IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1.
  • It serves to supply power to an appliance and from an appliance to other equipment.
  • To be installed by qualified person only.
  • Appliance couplers acc. to IEC 60320-1 are suitable to be used in cord sets and interconnection cord sets acc. to IEC 60799.

PRODUCT TYPES

POWER INPOWER OUTPOWER IN / POWER OUT Combination
APPLIANCE INLET
NAC3MPX-TOP
NAC3MPX-WOT-TOP
NAC3MPX-TRUE1
APPLIANCE OUTLET
NAC3FPX-TOP
NAC3FPX-WOT-TOP
NAC3FPX-ST-TOP
NAC3FPX-TRUE1
APPLIANCE INLET / APPLIANCE OUTLET
NAC3PX-TOP
NAC3PX-TRUE1

Diagram: Connector NAC3F-TRUE1-CG

Diagram: Plug Connector NAC3M-TRUE1-CG

Products are in compliance with:

IEC 60320-1EN IEC 60320-1UL 60320-1CSA C22.2 No. 60320-1
✔️✔️✔️✔️

Ratings:

IEC 60320-1UL 60320-1 CSA C22.2 No. 60320-1
16A 250V AC
Conductor cross section:1.5 - 2.5 mm²14 - 12 AWG
Cable diameter:8 - 13 mm0.31 - 0.51 inches

CABLE LIST

Approved cables:3 x 1.5 mm² ✔️3 x 2.5 mm² ✔️14/3 AWG ✔️12/3 AWG ✔️
H07RN-F
SJOOW

2 ASSEMBLY INFORMATION

A

Diagram: A cable is shown prepared for assembly. A black bushing (1) and a grey chuck (2) are positioned over the cable, ready to be slid onto it. Note: Chuck and Bushing cannot be placed over the cable after the assembly of the insert. For easier assembly, use a cable lubricant.

B

Diagram: Cable preparation for IEC 60320-1 / EN IEC 60320-1 shows 24 mm [0.94"] of outer jacket stripped and 9 mm [0.35"] of insulation stripped from conductors. Cable preparation for UL 60320-1 / CSA C22.2 No. 60320-1 shows similar stripping.

C

Diagram: Wiring for IEC 60320-1 / EN IEC 60320-1 shows L (brown), N (blue), and Ground (green/yellow). Wiring for UL 60320-1 / CSA C22.2 No. 60320-1 shows L (black), N (white), and Ground (green). A detail shows a contact with a screw, indicating Torx size T8 and a torque value of 0.7 Nm (6.2 inch pound / 0.52 lb.ft).

D

Diagram: Assembly sequence: 1. Position chuck (1) on insert (2). 2. Slide insert (2) with chuck (1) together into housing (3). Important note: Align the chuck by positioning the nose into the keyway. 3. Slide bushing (4) over chuck (1).

3 FOR DISASSEMBLY

Instructions: 1. Use the Neutrik tool HTLACB. 2. Position the tool on the surfaces and open the clamping sleeve. Diagram: The Neutrik tool HTLACB is shown engaging with the connector to release a clamping sleeve.

4 SAFETY INFORMATION

CAUTION

To ensure protection category, do not expose the connection to bending forces (e.g., do not attach loads to the cable, no free-dangling cable windings etc.). Diagram: A cable connected to the connector is shown with a label indicating "FORCE" applied to it, highlighting the risk of bending.

SAFETY WARNING

For safety reasons, appliance couplers must be replaced in case of any broken parts or excessive wear and tear.

5 Application and Safety Instructions

A Assembly

  • Use appropriate personal protective equipment.
  • Assemble Neutrik components only with designated and specified components.
  • Replacement parts are suitable only when used with designated components. Product characteristics guaranteed only in intended combination.
  • Protect from UV radiation if stored unassembled.

B Application

  • Exclusively intended for installation in electronic equipment or similar devices.
  • Not for medical applications, potentially explosive or flammable environments, or as climbing aids (Caution: Electrical hazards!).
  • Rated values marked on product and packaging.
  • Protect from oils and coolants.
  • Ensure connectors are plugged in or protected against moisture with a suitable protective cap in humid environments.

C Operation

  • Safety evaluated under standard laboratory conditions.
  • Product safety in intended application is the responsibility of the party involved after mounting or installation.
  • Check contact area for dry surfaces before plugging in.
  • Product surfaces may cause burns at elevated ambient temperatures; use appropriate protective equipment.
  • Customer is responsible for compliant use as an appliance coupler and for the de-energized state of appliance sockets/plugs.
  • Use only Neutrik products and components.
  • Unsuitable for vulnerable consumers.
  • Suitable for normal use at ambient temperatures not normally exceeding +40 °C (average over 24h not exceeding +35 °C), with a lower limit of -5 °C.
  • Protect against mechanical shocks.
  • Check regularly for suitability and observe local maintenance regulations.

D Cleaning

  • Clean only with dry and lint-free materials or compressed air.
  • Do not clean while under load. Clean only when not connected to voltage and without cleaning agents.

E Damages

  • Handle products with care.
  • Check suitability if visible damages occur.
  • Disposal must comply with applicable local laws and regulations.

6 Compatibility Information

Products are suitable for use with listed products. Suitability and safety must be assessed before commissioning when used with other products.

Compatibility Table:

NAC3F-TRUE1-CGNAC3M-TRUE1-CG
NAC3FPX-TRUE1Not applicableCertified acc. to: UL 60320-1 EN IEC 60320-1
NAC3FPX-TOPNot applicableCertified acc. to: UL 60320-1 EN IEC 60320-1
NAC3MPX-TRUE1Certified acc. to: UL 60320-1 EN IEC 60320-1Not applicable
NAC3MPX-TOPCertified acc. to: UL 60320-1 EN IEC 60320-1Not applicable
NAC3PX-TOPCertified acc. to: UL 60320-1 EN IEC 60320-1Tested acc. to: UL 60320-1 EN IEC 60320-1

IP Protection Class Table:

NAC3F-TRUE1-CGNAC3M-TRUE1-CG
NAC3FPX-TRUE1IP65/IP66/IP67IP65/IP66/IP67
NAC3MPX-TRUE1Not applicableNot applicable
NAC3PX-TRUE1IP65/IP66/IP67IP65/IP66/IP67
NAC3FPX-TOPIP65/IP66/IP67IP65/IP66/IP67
NAC3MPX-TOPNot applicableNot applicable
NAC3PX-TOPIP65/IP66/IP67IP65/IP66/IP67

Diagram: Mated Connector SCF-TRUE1-01 has IP65/IP67 rating. Diagram: Mated Connector SCNAC-FX has IP65 rating and is shown connected to a DEVICE.

7 More Information on the website

Visit: https://www.neutrik.com/en/products/audio/powercon

Document No.: BDA 697 V5

Date: 2025-08-27

Manufacturer: Neutrik AG, LI-9494 Schaan

Website: www.neutrik.com

Data subject to change without prior notice. © 2025 NEUTRIK®. NEUTRIK®, powerCON are registered trademarks of Neutrik AG. ALL RIGHTS RESERVED.

Models: BDA 728 V1, NAC3F-TRUE1-CG, NAC3M-TRUE1-CG, NAC3F-TRUE1-CG PowerCON TRUE1 Cable Connector, NAC3F-TRUE1-CG, PowerCON TRUE1 Cable Connector, Cable Connector, Connector

File Info : application/pdf, 5 Pages, 6.24MB

PDF preview unavailable. Download the PDF instead.

BDA 728 V1 - powerCON TRUE1 Cable Connector NAC3F-TRUE1-CG & NAC3M-TRUE1-CG

References

Acrobat Distiller 25.0 (Windows)

Related Documents

Preview Neutrik powerCON TRUE1 NAC3F-TRUE1-S & NAC3F-TRUE1-L Product Manual
Comprehensive product manual for Neutrik powerCON TRUE1 NAC3F-TRUE1-S and NAC3F-TRUE1-L appliance couplers, detailing application, safety instructions, assembly, disassembly, and operation.
Preview Neutrik powerCON TRUE1 NAC3FPX-TRUE1 Chassis Appliance Outlet Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 NAC3FPX-TRUE1 chassis appliance outlet, detailing application, safety instructions, assembly, compatibility, and specifications.
Preview Neutrik powerCON TRUE1 NAC3M-TRUE1-S/L Product Manual and Safety Guide
Comprehensive product manual for Neutrik powerCON TRUE1 connectors (NAC3M-TRUE1-S, NAC3M-TRUE1-L), covering application, safety instructions, assembly, disassembly, compatibility, and technical specifications.
Preview Neutrik powerCON TRUE1 NAC3FPX-TRUE1 Chassis Connector Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 NAC3FPX-TRUE1 chassis connector. Details application, safety instructions, assembly procedures, compatibility information, and technical specifications, emphasizing IP65 and IP67 ratings.
Preview Neutrik powerCON TRUE1 Chassis Appliance Outlet NAC3FPX-TRUE1 Product Manual
Comprehensive product manual for the Neutrik powerCON TRUE1 chassis appliance outlet (NAC3FPX-TRUE1), detailing application, safety instructions, assembly, compatibility, and specifications. Features IP65/IP67 rating for robust power connections.
Preview Neutrik powerCON TRUE1 NAC3MPX-TRUE1 Chassis Appliance Inlet - Product Manual
Official product manual for the Neutrik powerCON TRUE1 NAC3MPX-TRUE1 chassis appliance inlet connector, detailing application, safety instructions, assembly, compatibility, and technical specifications.
Preview Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L Cable Connector Product Manual
Detailed product manual for the Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L appliance coupler, covering application instructions, assembly, disassembly, safety guidelines, and technical specifications.
Preview Neutrik powerCON TRUE1 NAC3F-TRUE1-S & NAC3F-TRUE1-L Product Manual
Comprehensive product manual for Neutrik powerCON TRUE1 connectors (NAC3F-TRUE1-S, NAC3F-TRUE1-L), detailing application, safety instructions, assembly, disassembly, operation, cleaning, damages, and compatibility. Features IP65/IP67 rating and compliance with IEC, UL, and CSA standards.