Elitech LogEt 6 Multilingual Specification
Document Version: V1.0
Safety Instructions and Precautions
To ensure that you install and use this product correctly, please read and strictly comply with the following terms:
Battery
- ⚠️ Please use original or technically compatible batteries. Do not use batteries that do not meet product specifications to prevent damage to equipment or other malfunctions.
- ⚠️ Do not disassemble, squeeze, hit, or heat batteries privately, and do not place batteries in fire, as this may cause battery explosions and fires.
External Power Supply
- When external power supply is required, please use the power adapter configured for this device.
- Do not use other power adapters that do not meet the external connection technical specifications, otherwise it may damage the instrument and equipment, and even cause a fire.
Equipment
- In flammable and explosive gas environments, please use this equipment in accordance with compliance requirements, otherwise it may cause explosions and fires.
- During the use of the device, if the device emits a burnt or other odor, the power supply should be immediately cut off and the manufacturer or supplier should be contacted in a timely manner.
Attention
- If the equipment is not used for a long time, it should be removed and stored in the packaging box in a dry and cool environment.
- Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may affect the accuracy of the device and even damage it.
- Do not use the device in harsh environments to avoid instrument short circuits, burns, and other malfunctions caused by adverse weather conditions such as rain and lightning.
- When the recorder is offline (no data upload), please confirm the networking status of the device.
- Please use within the measurement range of the recorder.
- Please do not place the external probe directly in a liquid environment to avoid equipment damage.
- Please do not forcefully impact this recorder.
The measured values of the recorder may be affected by the following factors:
Temperature error:
- Placed in the measurement environment for too short a stable time.
- Close to heat sources, cold sources, or directly in a water soaked state.
Humidity error:
- Placed in the measurement environment for too short a stable time.
- Long term exposure to steam, water mist, water curtains, or condensation environments.
Pollution:
- Being in a dusty or other polluted environment.
Product Overview and Appearance
The LogEt 6 is a disposable dry ice recorder with a built-in probe. Equipped with ultra-low temperature sensors as standard, the entire machine can directly record temperature in an environment of -85°C. It can export reports or automatically generate PDF files through data center software, with 16000 sets of storage, 30 days of battery life, 2 years of shelf life, and support for shadow data function before and after. It is widely used in freezers, medical insulation boxes, laboratories, and other scenarios.
Device Diagram
The device is labeled LogEt 6 PT. Key components are:
- ① USB interface: For connecting to a computer.
- ② LED: Status indicator light.
- ③ LCD screen: Displays readings and status.
- ④ Stop button: Long press for 5 seconds to stop recording.
- ⑤ Start button: Press to cycle through display modes; long press for 5 seconds to start recording.
- ⑥ External probe interface (reserved): For an optional external probe.
- ⑦ Battery holder: Houses the battery.
LCD Display Information
The LCD screen displays various information, indicated by icons or labels:
- ① max/min/avr/MTK/log quantity: Displays maximum, minimum, average, MKT (Mean Kinetic Temperature), or the number of recorded data points.
- ② upper limit: Indicates the upper alarm limit.
- ③ lower limit: Indicates the lower alarm limit.
- ④ working condition: Shows the operational status.
- ⑤ battery level: Displays the remaining battery power.
- ⑥ Temperature/humidity values: Shows the current temperature or humidity readings.
- ⑦ date: Displays the current date.
- ⑧ time: Displays the current time.
Model List and Specifications
Model List | LogEt 6 PT | |
---|---|---|
Configuration | Built-in ultra-low temperature (dry ice) temperature sensor | |
Main sensor parameters | Temperature sensor | |
Temperature measurement range | -85°C ~ 50°C | |
Temperature measurement accuracy | ±0.5°C (-20°C ~ 40°C); ±1°C (other) | |
Temperature resolution | 0.1°C | |
Specifications | ||
Storage capacity | 16000 | |
Data interface | USB A | |
Battery | LS14250 lithium battery | |
Shelf-life | 2 Years | |
Battery life | 30 Days (log interval 5min) | |
Communication module/mode | USB interface | |
Protection grade | IP65 | |
Product dimensions (height*length*width) | 100*46*19mm | |
Weight | 60g | |
Work environment | -85°C ~ 50°C | |
Physical buttons | Start/Stop | |
Alarm method | LED | |
Adaptation software | Elitechlog |
Operating Instructions
Key functions:
- Start button: In normal display mode, press the start button to display the current temperature, and continue pressing to switch temperature data, date and time, number of records, maximum value, and minimum value; Press and hold for 5 seconds to start recording.
- Stop button: Long press for 5 seconds to stop recording.
Legend status indication:
Indicator | Description | Example/Icon |
---|---|---|
1. Timed start/Delay start | Indicates a scheduled start or delayed start is set. | ⏳ |
2. Not start | Indicates recording has not started. | ❌ |
3. Started | Indicates recording is active. | ▶️ |
4. Recorded points | Shows the number of data points recorded. | ? (e.g., 16000) |
5. Maximum temperature | Displays the highest recorded temperature. | ?️⬆️ (e.g., 58.8°C) |
6. Minimum temperature | Displays the lowest recorded temperature. | ?️⬇️ (e.g., -20.8°C) |
7. MKT value | Displays the Mean Kinetic Temperature. | MKT (e.g., 8.0°C) |
8. Average temperature | Displays the average recorded temperature. | ?️AVG (e.g., 8.0°C) |
9. High temperature limit 3 | Upper alarm limit 3. | ?️H3 (e.g., 60.0°C) |
10. High temperature limit 2 | Upper alarm limit 2. | ?️H2 (e.g., 50.0°C) |
11. High temperature limit 1 | Upper alarm limit 1. | ?️H1 (e.g., 40.0°C) |
12. Low temperature limit 1 | Lower alarm limit 1. | ?️L1 (e.g., 10.0°C) |
13. Low temperature limit 2 | Lower alarm limit 2. | ?️L2 (e.g., -2.0°C) |
14. High humidity limit | Upper humidity alarm limit. | ?⬆️ (e.g., 88.0%) |
15. Low humidity limit | Lower humidity alarm limit. | ?⬇️ (e.g., 28.8%) |
16. Maximum humidity | Displays the highest recorded humidity. | ?MAX (e.g., 63.8%) |
17. Minimum humidity | Displays the lowest recorded humidity. | ?MIN (e.g., 3.8%) |
18. Average humidity | Displays the average recorded humidity. | ?AVG (e.g., 53.8%) |
19. Current date/time | Displays the current date and time. | ?⏰ (e.g., 180606 10:50:28) |
20. Sensor error | Indicates a sensor malfunction. | ⚠️ (e.g., Err) |
21. PDF generation progress | Shows the progress of PDF report generation. | ? (e.g., PdF 88%) |
22. No alarm | Indicates no active alarms. | ✔️ |
23. Alarmed | Indicates an alarm condition is active. | ? |
24. Marked | Indicates a marked data point. | ? |
25. USB communicating | Indicates the device is communicating via USB. | ? (e.g., CUS6) |
Software Operation
1. Download software:
Download and install the "Jingchuang Data Center" software from www.e-elitech.com/xiazaizhongxin (China) or www.elitechlog.com/software (other countries).
2. Read data:
- Connect the computer using a USB interface.
- Open the "Jingchuang Data Center" and wait for the link to complete.
- Open the PDF file directly on your computer or open the summary/historical data within "Jingchuang Data Center" to view the data.
Notes:
- Data can be directly read without the need for the "Jingchuang Data Center" software.
- After the device is taken out of a low-temperature environment, it needs to be left to stand for a period of time and wait for it to return to room temperature before the LCD screen displays data.
3. Export data:
Click on Summary/Historical Data, select Export Data, and choose the format to export.
Accessories List
- Host * 1
- Instruction manual (electronic version)
- Calibration certificate (electronic version)
Warranty and After-Sales Service
Product warranty: 1 year
This product can be returned, replaced, or repaired within 7 days from the date of purchase due to performance failure. The warranty period is one year from the date of purchase (based on valid purchase receipts). During the warranty period, any malfunctions caused by quality problems of the product under normal use will be repaired free of charge. The shipping cost for repairing the product shall be borne unilaterally by the sender.
Exclusions from Warranty:
If any of the following situations are met, it is not within the scope of after-sales guarantee:
- Damage caused by force majeure, such as earthquakes, fires, floods, typhoons, etc.
- Damage caused by human factors such as improper use, maintenance, and storage by consumers.
- Damage caused by maintenance, disassembly, etc. by non-Elitech service personnel or authorized service providers.
- Exceeding the warranty period and scope.
- Natural wear and tear, consumption, and aging of products (such as shells, cables, etc.).