Elitech LogEt 5i User Manual

Single-Use IoT Data Logger

Product Presentation

The Elitech single-use IoT data logger LogEt 5i integrates multiple factors monitoring, including temperature, humidity, light, shock, and 4G networking, to provide a comprehensive environmental data solution. The device is equipped with world-famous high-precision sensors, capable of collecting and monitoring temperature and humidity data in various environments. Rapid start can be set via physical button, platforms, or timer, ensuring the efficiency and quality of logistics. The LogEt 5i inherits the advantages of traditional temperature and humidity data loggers while innovating and upgrading its functions, offering a comprehensive and convenient environment data monitoring solution.

Device Components:

LCD Display Indicators:

Note: To ensure data reliability, do not open the record if the battery power is less than 10% to 20%.

Selection Table (Standard Light and Vibration Sensors)

Model Probe Type Measuring Range Accuracy
LogEt 5i T Built-in temperature -30°C~70°C ±0.5°C
LogEt 5i TH Built-in temperature & humidity -30°C~70°C
0%RH~100%RH
±0.5°C ±5%RH
LogEt 5i TLE External temperature & built-in temperature Outlay: -200°C~150°C
Built-in: -30°C~70°C
±0.5°C (-40°C~85°C)
±1°C (-100°C~150°C)
±2°C (others)

Technical Parameters

Operating Instructions

1. Add Equipment

Log on to the platform website: http://new.i-elitech.com, or scan the QR code to download and install the APP. Register, sign in, and add devices as prompted.

[QR code for Android APP] [QR code for iOS APP]

2. Activation

Long press the button for 5 seconds, and the screen appears normally, indicating that the device is activated. [✔️] indicates successful activation.

Note: Clicking the button screen to display normally also indicates activation.

3. Airplane Mode

Open: Long press the button for 5 seconds. The screen displays a [✈️] logo, indicating that the flight mode is successfully started.

Close: Long press the button for 5 seconds. The screen displays a [?✈️] sign, indicating that the flight mode is closed.

Note: For other flight modes, please operate through the platform or APP.

4. Start the Record

Press the [START/STOP] button for 5 seconds. The screen displays a [▶️] sign, indicating the startup record. If the sign is flashing, the delay countdown state is entered. After the delay, the record starts automatically.

5. Stop Recording

Long press the [START/STOP] button for 5 seconds. The screen displays a [■] sign, indicating that recording has stopped successfully.

6. Data Export

The device connects to a computer via USB interface using the data cable, automatically generating data reports in PDF + CSV format. You can copy the generated report to your computer for saving.

[Screen showing 'Report generation'] [Screen showing 'Device is connected to the computer']

Operating Instructions for Freight Management

  1. After logging in to the platform or APP, click the 'Freight Management' menu of the main menu.
  2. Click the "Configure" menu on the home page to create and add "user management", "Carrier", "location", "alarm preset", and "freight template" successively.
  3. Click the "Freight Management" menu on the home page to create and manage the freight transport.

Note: For detailed operation manuals, see the operation instructions in the platform or APP.

The LED Indicator Light Instructions

Device Status/Operation LED Indicator Display Triggering Method
Malfunction/Low Battery (below 5%) No Flashing Short Press Button
No Calibration Green & Red Flashing x 2 Short Press Button
No Activation Red & Red Flashing x 2 Short Press Button
No Start Green & Red Flashing x 1 Short Press Button
Start Recording Green Flashing x 5 Short Press Button x 5s
Delayed/Scheduled Start Green to Red Flashing x 1 Short Press Button x 10s or Auto Flashing
Recording Green Flashing x 1 (OK) [No specific trigger method listed, implies automatic]
Stop Recording Red Flashing x 1 (Alarming) Long Press Right Button x 5s
Recording Stopped Green Flashing x 2 (OK) Short Press Button
Report Generating Red Flashing x 2 (Alarming) [No specific trigger method listed]
USB Connecting Green to Red Flashing x 1 Connect USB
Clear Report Label Green & Red On Long Press Left Button x 5s
Communication Normal Green & Red Flashing Flashing When Connecting to Network
Communication Error Blue Flashing x 3 Flashing When Connecting to Network
Start Airplane Mode Red & Blue Flashing x 3 Long Press Left Button x 5s
Stop Airplane Mode Blue Flashing x 5 Long Press Left Button x 5s
Clear the report logo At the same time flashing Long Press Left Button x 5s (USB connected)

LCD Explicit Declaration

Safety Instructions

Battery

Device

Precautions

Factors Affecting Measurement Values:

Document Version: V1.2

Company Information

Company Name: Elitech Technology Inc

Address: 2528 Qume Dr, Ste 2 San Jose, CA 95131 USA

Tel: 408-898-2866 (office)

Official Website: www.elitechlog.com

Email: coldchain@e-elitech.com

PDF preview unavailable. Download the PDF instead.

LogEt-5-instructions Adobe PDF library 17.00

Related Documents

Preview Elitech RCW-5i Single-Use IoT Data Logger User Manual
User manual for the Elitech RCW-5i single-use IoT data logger, detailing its product presentation, technical specifications, selection table, operation instructions, data export, LED indicator meanings, LCD display declarations, and safety precautions.
Preview Elitech RCW-400A User Manual: Temperature and Humidity Data Logger
Comprehensive user manual for the Elitech RCW-400A 4-channel temperature and humidity data logger. Covers features, specifications, operation, sensor installation, and Elitech cloud/app integration for remote monitoring.
Preview Elitech LogEt 1 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 1 series of single-use data loggers, covering LogEt 1 (temperature), LogEt 1TH (temperature-humidity), and LogEt 1 Bio (high accuracy temperature). Includes specifications, operation, status indication, and warnings.
Preview Elitech LogEt 8 Series Data Logger User Manual - Temperature and Humidity Monitoring
Comprehensive user manual for the Elitech LogEt 8 Series data loggers, detailing specifications, operation, installation, and troubleshooting for temperature and humidity monitoring in cold chain logistics.
Preview Elitech RCW-800W Wi-Fi IoT Temperature and Humidity Data Logger User Manual
Comprehensive guide to the Elitech RCW-800W Wi-Fi IoT data logger, covering features, specifications, operation, and app configuration for real-time temperature and humidity monitoring.
Preview Elitech IoT & Cold Chain Data Loggers | Comprehensive Product Catalog
Explore Elitech's extensive range of IoT and cold chain data loggers, including temperature, humidity, and multi-use devices. Discover features, technical specifications, and software solutions for reliable monitoring and compliance.
Preview Elitech RCW-400A User Manual: Temperature and Humidity Data Logger
Comprehensive user manual for the Elitech RCW-400A, a 4-channel temperature and humidity data logger with GSM and cloud connectivity. Learn about features, specifications, installation, and operation.
Preview Elitech RC-61/GSP-6 Temperature and Humidity Data Logger User Manual
Comprehensive user manual for the Elitech RC-61/GSP-6 temperature and humidity data logger. Learn about its features, specifications, operation, status indications, battery replacement, and default parameters.