Elitech LogEt 5i User Manual
Single-Use IoT Data Logger
Product Presentation
The Elitech single-use IoT data logger LogEt 5i integrates multiple factors monitoring, including temperature, humidity, light, shock, and 4G networking, to provide a comprehensive environmental data solution. The device is equipped with world-famous high-precision sensors, capable of collecting and monitoring temperature and humidity data in various environments. Rapid start can be set via physical button, platforms, or timer, ensuring the efficiency and quality of logistics. The LogEt 5i inherits the advantages of traditional temperature and humidity data loggers while innovating and upgrading its functions, offering a comprehensive and convenient environment data monitoring solution.
Device Components:
- ① Backmounted hanging hole
- ② Liquid crystal display
- ③ LED pilot lamp
- ④ Start-stop button
- ⑤ Serial number
- ⑥ Light sensor
- ⑦ Power supply + data interface
- ⑧ Built-in sensor
- ⑨ Activation / Flight mode button
- ⑩ External sensor
LCD Display Indicators:
- ① Operative mode
- ② Function declaration
- ③ Airplane mode
- ④ Signal condition
- ⑤ Battery capacity
- ⑥ Light and vibration alarm signs
- ⑦ Time and the number of record notes
- ⑧ Temperature and humidity value
Note: To ensure data reliability, do not open the record if the battery power is less than 10% to 20%.
Selection Table (Standard Light and Vibration Sensors)
Model | Probe Type | Measuring Range | Accuracy |
---|---|---|---|
LogEt 5i T | Built-in temperature | -30°C~70°C | ±0.5°C |
LogEt 5i TH | Built-in temperature & humidity | -30°C~70°C 0%RH~100%RH |
±0.5°C ±5%RH |
LogEt 5i TLE | External temperature & built-in temperature | Outlay: -200°C~150°C Built-in: -30°C~70°C |
±0.5°C (-40°C~85°C) ±1°C (-100°C~150°C) ±2°C (others) |
Technical Parameters
- Shock range: 0g~16g
- Light intensity range: 0~52000Lux
- Resolution ratio: 0.1°C/0.1%RH/0.1g/1Lux
- Button: Double button design
- LED light: Red and green, red and blue LED indicator lights
- Display screen: Broken code display
- Location mode: LBS + GPS (optional)
- Memory point: 32000
- Shadow data: Prestant +Afterstop
- Interrecord gap: 1min~24h; default: 5min
- Upload interval: 5min~24h; default: 60min
- Data upload method: 4G+2G
- Mode of starting freight: Button pressing, platform, and timing
- Freight stop mode: Button, platform, and fill up
- Repeat the start: 3 times (not off shelf life)
- Airplane mode: Key button, timing, electronic fence
- Alarm mode: Overlimit, low power
- Battery type: 3.0V disposable lithium manganese battery 4800 mAh
- OTA upgrade: Upgrade is available through the data management software and the platform
- Classification of waterproof: IP65 (built-in)
- Work environment: -30°C~70°C, 0% RH ~ 100% RH (no condensation)
- Storage environment: 15~30°C, 20~75%RH
- Specification and dimension: 103 x 61.3 x 30 (mm)
Operating Instructions
1. Add Equipment
Log on to the platform website: http://new.i-elitech.com, or scan the QR code to download and install the APP. Register, sign in, and add devices as prompted.
[QR code for Android APP] [QR code for iOS APP]
2. Activation
Long press the button for 5 seconds, and the screen appears normally, indicating that the device is activated. [✔️] indicates successful activation.
Note: Clicking the button screen to display normally also indicates activation.
3. Airplane Mode
Open: Long press the button for 5 seconds. The screen displays a [✈️] logo, indicating that the flight mode is successfully started.
Close: Long press the button for 5 seconds. The screen displays a [?✈️] sign, indicating that the flight mode is closed.
Note: For other flight modes, please operate through the platform or APP.
4. Start the Record
Press the [START/STOP] button for 5 seconds. The screen displays a [▶️] sign, indicating the startup record. If the sign is flashing, the delay countdown state is entered. After the delay, the record starts automatically.
5. Stop Recording
Long press the [START/STOP] button for 5 seconds. The screen displays a [■] sign, indicating that recording has stopped successfully.
6. Data Export
The device connects to a computer via USB interface using the data cable, automatically generating data reports in PDF + CSV format. You can copy the generated report to your computer for saving.
[Screen showing 'Report generation'] [Screen showing 'Device is connected to the computer']
Operating Instructions for Freight Management
- After logging in to the platform or APP, click the 'Freight Management' menu of the main menu.
- Click the "Configure" menu on the home page to create and add "user management", "Carrier", "location", "alarm preset", and "freight template" successively.
- Click the "Freight Management" menu on the home page to create and manage the freight transport.
Note: For detailed operation manuals, see the operation instructions in the platform or APP.
The LED Indicator Light Instructions
Device Status/Operation | LED Indicator Display | Triggering Method |
---|---|---|
Malfunction/Low Battery (below 5%) | No Flashing | Short Press Button |
No Calibration | Green & Red Flashing x 2 | Short Press Button |
No Activation | Red & Red Flashing x 2 | Short Press Button |
No Start | Green & Red Flashing x 1 | Short Press Button |
Start Recording | Green Flashing x 5 | Short Press Button x 5s |
Delayed/Scheduled Start | Green to Red Flashing x 1 | Short Press Button x 10s or Auto Flashing |
Recording | Green Flashing x 1 (OK) | [No specific trigger method listed, implies automatic] |
Stop Recording | Red Flashing x 1 (Alarming) | Long Press Right Button x 5s |
Recording Stopped | Green Flashing x 2 (OK) | Short Press Button |
Report Generating | Red Flashing x 2 (Alarming) | [No specific trigger method listed] |
USB Connecting | Green to Red Flashing x 1 | Connect USB |
Clear Report Label | Green & Red On | Long Press Left Button x 5s |
Communication Normal | Green & Red Flashing | Flashing When Connecting to Network |
Communication Error | Blue Flashing x 3 | Flashing When Connecting to Network |
Start Airplane Mode | Red & Blue Flashing x 3 | Long Press Left Button x 5s |
Stop Airplane Mode | Blue Flashing x 5 | Long Press Left Button x 5s |
Clear the report logo | At the same time flashing | Long Press Left Button x 5s (USB connected) |
LCD Explicit Declaration
- Log: Number of points recorded (Display shows a number, e.g., 1888)
- Log: Number of points not uploaded (Display shows a number, e.g., 10008)
- Lo-Po: Low power (Display shows "Lo-Po")
- FULL: The number of uses has been used (Display shows "FULL")
- UP-Ld: Data not uploaded, probe fault (Display shows "UP-Ld")
- Data not uploaded, probe fault (Display shows a symbol like X ▶️ followed by dashes and E)
Safety Instructions
Battery
- Please use the original battery rather than any other ones to avoid possible damage or error to the device.
- Do not disassemble the battery without permission. No squeezing, hitting, heating, or burning the battery, otherwise, the battery may explode and lead to a fire.
Device
- This device is prohibited from being used in environments with flammable or explosive gas, otherwise, an explosion/fire may be caused.
- If peculiar smell emits from the device during use, please cut off power supply immediately and contact the manufacturer or supplier.
Precautions
- If the device will not be in use for a long period of time, it should be removed and stored in the package box in a dry and cool environment.
- Any unauthorized change to the device by the user is not allowed, which may affect accuracy or even damage the device.
- Do not use the device outdoors to avoid short circuits, burns, and other malfunctions caused by bad weather such as raining and thunder-lightings.
- If the data logger is offline (no data uploading) for a long period of time, please check its networking status.
- Use the data logger within its measurement range.
- Do not impact the data logger with force.
Factors Affecting Measurement Values:
- Temperature deviation: Stabilizing time too short for placing the device in the measurement environment. Near or even exposed to a heat/cold source.
- Humidity deviation: Stabilizing time too short for placing the device in the measurement environment. Long time exposed in steam, fog, waterfall, or condensation environment.
- Pollution: Exposed to dust or other polluted environment.
Document Version: V1.2
Company Information
Company Name: Elitech Technology Inc
Address: 2528 Qume Dr, Ste 2 San Jose, CA 95131 USA
Tel: 408-898-2866 (office)
Official Website: www.elitechlog.com
Email: coldchain@e-elitech.com