Goodman FTXNG-A Series Inverter Split Unit Air Conditioner Engineering Data
Brand: Goodman
Product Type: Air Conditioner
Introduction
This document provides engineering data for the Goodman FTXNG-A Series Inverter Split Unit Air Conditioner with Heatpump functionality. The series includes models FTXNG09A, FTXNG12A, and FTXNG18A, designed for wall-mounted installation and operating on a 208/230V, 60Hz power supply.
Model Name and Power Supply
Indoor Unit | Outdoor Unit | Power Supply |
---|---|---|
FTXNG09AXVJU | RXNG09AXVJU | 1 Phase, 208/230V, 60Hz |
FTXNG12AXVJU | RXNG12AXVJU | |
FTXNG18AXVJU | RXNG18A |
Nomenclature
The model numbers for the FTXNG-A series are structured to indicate specific features. Below is a breakdown of the nomenclature for both indoor and outdoor units:
Indoor Unit Nomenclature
Definition | Description |
---|---|
Unit Category | F: Air-Cooled Split Indoor Unit |
Product Type | T: Wall Mounted |
System | X: Inverter, Heatpump |
Grade | N: R410A, Internet Model |
Brand | G: Goodman Brand |
Capacity Indication* | 09: 9,000 Btu/h |
Major Design Category | A: A Series |
Factory Origin | X: Malaysia |
Power Supply | VJ: 208/230V / 1Phase / 60Hz |
Country | U: United States |
*Capacity value under Nomenclature is an indication. Please refer to Specifications Data for exact capacity value.
Outdoor Unit Nomenclature
Definition | Description |
---|---|
Unit Category | R: Air-Cooled Split Outdoor Unit |
System | X: Inverter, Heatpump |
Grade | N: R410A, Internet Model |
Brand | G: Goodman Brand |
Capacity Indication* | 09: 9,000 Btu/h |
Major Design Category | A: A Series |
Factory Origin | X: Malaysia |
Power Supply | VJ: 208/230V / 1Phase / 60Hz |
Country | U: United States |
Functions
The FTXNG-A series offers a range of functions for comfortable and efficient operation:
Category | Functions | FTXNG09/12A RXNG09/12A |
FTXNG18A RXNG18A |
---|---|---|---|
Basic Function | Inverter | • | • |
Operation Limit for Cooling (°CDB)(O/D) | 10-46 | 10-46 | |
Operation Limit for Cooling (°FDB)(O/D) | 50-114.8 | 50-114.8 | |
Operation Limit for Heating (°CWB)(O/D) | -15-18 | -15-18 | |
Compressor | Operation Limit for Heating (°FWB)(O/D) | 5-64.4 | 5-64.4 |
Scroll Compressor | • | • | |
Swing Compressor | • | • | |
Comfortable Airflow | Rotary Compressor | - | - |
Power-airflow Flap | • | • | |
Power-airflow Dual Flaps | • | • | |
Power-airflow Diffuser | - | - | |
Wide Angle Louvers | • | • | |
Vertical Auto-Swing (Up and Down) | • | • | |
Comfort Control | Horizontal Auto-Swing (Right and Left) | • | • |
3D Airflow | - | - | |
Breeze Airflow | • | • | |
Operation | Auto Fan Speed | • | • |
Indoor Unit Quiet Operation | • | • | |
Intelligent Eye Operation | • | • | |
Automatic Defrosting | • | • | |
Automatic Operation | • | • | |
Programme Dry Function | • | • | |
Lifestyle Convenience | Fan Only | • | • |
Powerful Operation (Non Inverter) | • | • | |
Inverter Powerful Operation | • | • | |
Energy Saving Function | • | • | |
Sleep Mode | • | • | |
Lifestyle Convenience | Indoor Unit ON/OFF Button | • | • |
R/C with Backlight | • | • | |
Signal Receiving Sign (R/C) | • | • | |
Set Temperature Display (R/C) | • | • | |
Saranet Filter | • | • | |
Health & Clean | Anti-virus Filter / Gin-ION Filter | • | • |
Catechin Filter / Green Tea Filter | - | - | |
Titanium Apatite Air-Purifying Filter | • | • | |
PM 2.5 Filter | • | • | |
Streamer | • | • | |
Timer | Plasma | • | • |
Wipe Clean Flat Panel | • | • | |
Weekly Timer Operation (Wired R/C) | • | • | |
Worry Free (Reliability & Durability) | 24-hour ON/OFF Timer (R/C) | • | • |
Countdown ON/OFF Timer (R/C) | • | • | |
Auto Restart (after Power Failure) | • | • | |
Flexibility | Self-diagnosis | • | • |
Anti-corrosion Treatment of Outdoor Heat Exchanger | Blue Fin | Blue Fin | |
Pre-charged Piping Length | 32-13/16 ft | 32-13/16 ft | |
Remote Control Controller | Either Side Drain (Right or Left) | • | • |
WIFI Connectivity | • | • | |
BAG Connectivity | • | • | |
Remote Controller | DIII-NET Connectivity | • | • |
Wireless | BRC52B67 | BRC52B67 | |
Wired |
Note: •: Available, -: Not Available, •*: Optional
Specifications
The following tables detail the technical specifications for the Goodman FTXNG-A series air conditioners, covering cooling and heating performance, dimensions, electrical characteristics, and more. The specifications are provided for the FTXNG09A/RXNG09A, FTXNG12A/RXNG12A, and FTXNG18A/RXNG18A models.
General Specifications
Model | Rated Capacity (Min. ~ Max.) | Moisture Removal (gal/h) | Rated Running Current (A) | Rated Power Consumption (W) | EER2 | SEER2 | COP | HSPF2 | Power Factor (Rated) | |
---|---|---|---|---|---|---|---|---|---|---|
Cooling (kW) | Heating (kW) | |||||||||
FTXNG09A / RXNG09A | 2.57 (1.30 - 3.00) | 2.75 (1.30 - 3.80) | 0.09 | 3.82 | 800 | 11.0 | 18.0 | 3.56 | 9.0 | N/A |
FTXNG12A / RXNG12A | 3.22 (1.30 - 3.90) | 3.31 (1.30 - 4.81) | 0.18 | 4.55 | 1004 | 8.5 | 18.0 | 3.30 | 9.0 | N/A |
FTXNG18A / RXNG18A | 5.27 (1.96 - 5.86) | 5.24 (1.70 - 6.60) | 0.41 | 7.53 | 1714 | 10.5 | 18.0 | 3.30 | 8.5 | N/A |
Indoor Unit Specifications (Example: FTXNG09A)
Parameter | Value |
---|---|
Front Panel Colour | WHITE |
Airflow Rate (Turbo/High/Medium/Low/Quiet) | 466/431/322/249/142 CFM |
Sound Pressure Level (H/M/L/Q) | 43/36/29/19 dBA |
Fan Type | CROSS FLOW |
Fan Drive | DIRECT CURRENT |
Fan Speed | 3 STEPS, QUIET, AUTO, TURBO |
Fan Motor Output | 29 W |
Dimensions (H x W x D) | 11-1/3 x 30-5/16 x 9-3/16 inches (288 x 770 x 234 mm) |
Weight | 20.3 lbs (9.2 kg) |
Outdoor Unit Specifications (Example: RXNG09A)
Parameter | Value |
---|---|
Casing Colour | IVORY WHITE |
Airflow Rate (High) | 1083 CFM |
Sound Pressure Level | 46 dBA |
Fan Type | PROPELLER |
Fan Drive | DIRECT CURRENT |
Index of protection (IP) | 24 |
Insulation Grade | E |
Fan Motor Output | 32 W |
Compressor Type | HERMETIC SWING |
Dimensions (H x W x D) | 21-11/16 x 26-1/2 x 11-3/16 inches (550 x 675 x 284 mm) |
Weight | 55 lbs (25 kg) |
Note: Capacities are based on specific test conditions (e.g., Indoor 80°FDB/67°FWB for cooling, 70°FDB for heating; Outdoor 95°FDB for cooling, 47°FDB/43°FWB for heating).
Dimensions
Detailed dimensional drawings are provided for both indoor and outdoor units to aid in installation planning.
Indoor Unit Dimensions
Diagrams show the front, rear, left, right, and bottom views of the indoor units FTXNG09/12A and FTXNG18A, with key dimensions indicated in inches and millimeters. These diagrams are for illustrative purposes only.
Diagram illustrating dimensions for FTXNG09/12A Indoor Unit. Diagram illustrating dimensions for FTXNG18A Indoor Unit.Outdoor Unit Dimensions
Diagrams show the front, rear, left, right, and bottom views of the outdoor units RXNG09/12A and RXNG18A, including details on mounting holes, service valves, and clearance requirements for installation. Key dimensions are provided in inches and millimeters. These diagrams are for illustrative purposes only.
Diagram illustrating dimensions and installation clearances for RXNG09/12A Outdoor Unit. Diagram illustrating dimensions and installation clearances for RXNG18A Outdoor Unit.Wiring Diagrams
Electrical wiring diagrams are provided for the indoor and outdoor units, illustrating the connections for power supply, motors, sensors, and control boards.
Indoor Unit Wiring Diagram (Model: FTXNG-A)
This diagram shows the internal wiring of the indoor unit, including connections for the fan motor (MF), air swing motor (MS), thermistors (TH1, TH2), display board, and optional Wi-Fi adapter or wired accessories.
Diagram showing the internal wiring of the FTXNG-A indoor unit.Outdoor Unit Wiring Diagrams
Separate diagrams are provided for the outdoor units RXNG09/12A and RXNG18A. These illustrate the connections for the compressor motor (MC), fan motor (MF), electronic expansion valve (EXV), four-way valve (4WV), fuses, terminal blocks, and sensors (outdoor air, heat exchanger, discharge). Field wiring connections are also indicated.
Diagram showing the wiring of the RXNG09/12A outdoor unit. Diagram showing the wiring of the RXNG18A outdoor unit.Piping Diagrams
Refrigerant piping diagrams illustrate the flow of refrigerant for cooling and heating modes for both indoor and outdoor units.
Indoor Unit Piping Diagrams
Diagrams for FTXNG09A, FTXNG12A, and FTXNG18A show the indoor heat exchanger, distributor, fan motor, and thermistor connections, along with field piping connections (1/4" and 3/8" copper tubing).
Diagram showing the refrigerant piping for the FTXNG09A indoor unit. Diagram showing the refrigerant piping for the FTXNG12A indoor unit. Diagram showing the refrigerant piping for the FTXNG18A indoor unit.Outdoor Unit Piping Diagrams
Diagrams for RXNG09A, RXNG12A, and RXNG18A illustrate the outdoor heat exchanger, propeller fan, compressor, four-way valve, electronic expansion valve, accumulator, strainers, mufflers, and thermistors. Field piping connections are also indicated.
Diagram showing the refrigerant piping for the RXNG09A outdoor unit. Diagram showing the refrigerant piping for the RXNG12A outdoor unit. Diagram showing the refrigerant piping for the RXNG18A outdoor unit.Capacity Tables
Extensive tables provide detailed cooling and heating capacity data for the FTXNG-A series models under various operating conditions. These tables list Total Capacity (TC), Sensible Heat Capacity (SHC), and Power Input (PI) in kW (or kBtu/h) for different combinations of indoor and outdoor temperatures (both Celsius and Fahrenheit). Interpolation is required to determine values for conditions not explicitly listed.
Key Information Presented in Capacity Tables:
- Cooling Capacities: Provided for indoor temperatures ranging from 14°C to 32°C (57.2°F to 89.6°F) and outdoor temperatures from 10°C to 46°C (50°F to 115°F).
- Heating Capacities: Provided for indoor temperatures ranging from 15°C to 27°C (59°F to 80.6°F) and outdoor temperatures from -15°C to 18°C (5°F to 64.4°F).
- Units: Capacity in kW or kBtu/h, Power Input in kW.
- Conditions: Capacities are based on a standard refrigerant piping length of 25 ft and a level difference of 0 ft.
Due to the extensive nature of these tables, specific values are not reproduced here but are available in the original document.
Capacity Correction Factor by Refrigerant Piping Length
Graphs illustrate the capacity correction factor based on the length of the refrigerant piping. These factors are applied to the nominal capacities to account for variations in piping length and refrigerant charge. The graphs show separate curves for cooling and heating, indicating how the correction factor decreases as piping length increases.
Graph showing capacity correction factor vs. piping length for FTXNG09A/RXNG09A and FTXNG12A/RXNG12A models. Graph showing capacity correction factor vs. piping length for FTXNG18A/RXNG18A models.Notes:
- The correction ratio is the same regardless of whether the outdoor unit is installed above or below the indoor unit.
- Capacity = Engineering data capacity x capacity correction factor.
- Actual unit piping length should not exceed the maximum specified length.
Operation Limit
The operation limit graphs define the permissible operating temperature ranges for the units in cooling and heating modes. These graphs plot outdoor temperature against indoor temperature to show the continuous operation zone and pull-down period.
Graph showing the cooling operation limits for the RXNG-A outdoor unit, plotting outdoor temperature (°FDB) against indoor temperature (°FWB). Graph showing the heating operation limits for the RXNG-A outdoor unit, plotting outdoor temperature (°FWB) against indoor temperature (°FDB).Sound Level
Sound level data is provided for the indoor units, measured in an anechoic chamber. This includes sound pressure levels across various octave bands and overall noise criteria.
Sound Pressure Level (Cooling)
Model | Speed | 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) | Overall (dBA) | Noise Criteria | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | ||||
FTXNG09A | High | 54 | 43 | 41 | 39 | 39 | 35 | 26 | 15 | 43 | 38 |
FTXNG09A | Med | 45 | 35 | 36 | 33 | 32 | 26 | 17 | 12 | 36 | 31 |
FTXNG09A | Low | 37 | 28 | 30 | 27 | 25 | 19 | 12 | 10 | 29 | 23 |
FTXNG09A | Quiet | 25 | 19 | 20 | 16 | 13 | 10 | 8 | 9 | 19 | 0 |
Model | Speed | 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) | Overall (dBA) | Noise Criteria | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | ||||
FTXNG12A | High | 44 | 36 | 42 | 40 | 43 | 37 | 29 | 19 | 45 | 42 |
FTXNG12A | Med | 34 | 29 | 35 | 33 | 34 | 28 | 19 | 12 | 37 | 33 |
FTXNG12A | Low | 26 | 24 | 30 | 29 | 27 | 21 | 14 | 11 | 31 | 25 |
FTXNG12A | Quiet | 17 | 19 | 18 | 16 | 13 | 11 | 10 | 9 | 19 | 0 |
Model | Speed | 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) | Overall (dBA) | Noise Criteria | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | ||||
FTXNG18A | High | 51 | 41 | 45 | 43 | 44 | 42 | 35 | 25 | 48 | 43 |
FTXNG18A | Med | 41 | 35 | 41 | 39 | 39 | 37 | 29 | 18 | 43 | 38 |
FTXNG18A | Low | 34 | 30 | 37 | 34 | 33 | 30 | 21 | 13 | 37 | 32 |
FTXNG18A | Quiet | 30 | 28 | 34 | 31 | 28 | 23 | 13 | 10 | 33 | 26 |
Sound Pressure Level (Heating)
Model | Speed | 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) | Overall (dBA) | Noise Criteria | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | ||||
FTXNG09A | High | 49 | 37 | 39 | 37 | 40 | 34 | 26 | 15 | 42 | 39 |
FTXNG09A | Med | 36 | 29 | 37 | 33 | 31 | 24 | 13 | 11 | 35 | 30 |
FTXNG09A | Low | 30 | 23 | 32 | 26 | 24 | 16 | 12 | 10 | 29 | 22 |
FTXNG09A | Quiet | 23 | 21 | 29 | 23 | 19 | 11 | 11 | 9 | 25 | 17 |
Model | Speed | 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) | Overall (dBA) | Noise Criteria | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | ||||
FTXNG12A | High | 47 | 36 | 40 | 38 | 41 | 34 | 23 | 12 | 43 | 40 |
FTXNG12A | Med | 39 | 29 | 37 | 33 | 32 | 24 | 14 | 11 | 36 | 31 |
FTXNG12A | Low | 29 | 25 | 32 | 28 | 26 | 17 | 12 | 11 | 30 | 24 |
FTXNG12A | Quiet | 28 | 24 | 29 | 25 | 20 | 12 | 10 | 10 | 26 | 19 |
Model | Speed | 1/1 Octave A-weighted Sound Pressure Level (dB, ref 20µPa) | Overall (dBA) | Noise Criteria | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|
63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | ||||
FTXNG18A | High | 52 | 40 | 43 | 42 | 42 | 39 | 30 | 16 | 46 | 41 |
FTXNG18A | Med | 45 | 35 | 39 | 38 | 37 | 34 | 24 | 12 | 41 | 36 |
FTXNG18A | Low | 38 | 31 | 38 | 34 | 32 | 25 | 14 | 11 | 36 | 31 |
FTXNG18A | Quiet | 37 | 29 | 35 | 31 | 29 | 23 | 12 | 10 | 33 | 28 |
NC Curve: A graph is provided showing Noise Criteria (NC) curves for different sound levels (Silent, Low, Medium, High, Turbo) across various octave band frequencies. This helps in assessing the perceived loudness of the unit in different environments.
NC Curve graph illustrating sound pressure levels across octave bands for different operating speeds.Electric Characteristic
This table details the electrical characteristics of the unit combinations, including Maximum Circuit Amps (MCA), Maximum Overcurrent Protection (MOP), Compressor Input Current (A), Rated Operating Frequency (RHz), Outdoor Fan Motor (OFM) and Indoor Fan Motor (IFM) power, and Maximum Operating Current (MOC).
Indoor Unit | Outdoor Unit | Hz-Volts | Voltage Range | MCA | MOP | COMP | OFM | IFM | |||
---|---|---|---|---|---|---|---|---|---|---|---|
A | kW | A | kW | A | kW | ||||||
FTXNG09A | RXNG09A | 60Hz-208V / 60Hz-230V | MAX. 60Hz 253V MIN. 60Hz 187V | 12.35 | 15 | 88 | 4.34 | 0.026 | 0.60 | 0.022 | 0.35 |
FTXNG12A | RXNG12A | 60Hz-208V / 60Hz-230V | MAX. 60Hz 253V MIN. 60Hz 187V | 12.40 | 15 | 96 | 5.57 | 0.026 | 0.61 | 0.022 | 0.40 |
FTXNG18A | RXNG18A | 60Hz-208V / 60Hz-230V | MAX. 60Hz 253V MIN. 60Hz 187V | 16.55 | 20 | 90 | 8.17 | 0.055 | 1.30 | 0.039 | 0.55 |
Notes:
- RHz indicates the maximum frequency for cooling and heating operation.
- RLA (not shown in table, but implied by 'A' under COMP) is the maximum current during operation.
- Maximum allowable voltage unbalance between phases is 2%.
- Wire size should be selected based on the larger value of MCA.
- Use a circuit breaker instead of a fuse.