Goodman GSX13 Split System Air Conditioner
Model Series: GSX13
Efficiency: 13 SEER / 11½ to 5 Tons
Cooling Capacity: 18,000 - 60,000 BTU/H
Product Overview
The Goodman GSX13 is a split system air conditioner designed for efficient and reliable cooling. It features a heavy-gauge galvanized-steel cabinet with an Architectural Gray powder-paint finish, Goodman® brand louvered sound control top design, and a steel louver coil guard.
Standard Features
- R-410A chlorine-free refrigerant
- Energy-efficient compressor
- Factory-installed filter drier
- Copper tube/aluminum fin coil
- Service valves with sweat connections and easy-access gauge ports
- Contactor with lug connection
- Ground lug connection
- AHRI Certified
- ETL Listed
Cabinet Features
- Goodman® brand louvered sound control top design
- Steel louver coil guard
- Heavy-gauge galvanized-steel cabinet
- Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
- Top and side maintenance access
- Single-panel access to controls with space provided for field-installed accessories
- Meets 2001 Florida Building Code unit integrity requirements for hurricane-type winds when properly anchored (Anchor bracket kits available).
Warranty: 10 Parts Limited Warranty (online registration required within 60 days of installation, except in California or Quebec).
Nomenclature Breakdown
The model number provides detailed information about the unit's specifications:
Code | Description |
---|---|
G | Brand: Goodman® Brand or Amana® Distinctions® Brand |
S | Product Category: Split System |
X | Unit Type: Condenser R-410A |
13 | Efficiency: 13 SEER |
036 | Nominal Capacity: 3 Tons (Example for 036 model) |
1 | Electrical: 208-230 V, 1 Phase, 60 Hz |
* (9, 10, 11) | Engineering/Revision/Optional: Used for order entry or inventory management. |
Product Specifications
Detailed specifications are provided for various models, including:
- Capacities: Nominal Cooling (BTU/h), SEER/EER, Decibels
- Compressor: RLA, LRA
- Condenser Fan Motor: Horsepower, FLA
- Refrigeration System: Refrigerant Line Size, Liquid/Suction Line Size, Valve Type, Refrigerant Charge, Orifice Size
- Electrical Data: Voltage, Minimum Circuit Ampacity, Max. Overcurrent Protection, Min/Max Volts, Electrical Conduit Size
- Equipment Weight & Ship Weight
Note: Specific values vary by model number.
Expanded Cooling Data
Extensive tables provide detailed cooling performance data for each model under various outdoor ambient temperatures (65°F to 115°F) and indoor wet bulb temperatures (59°F to 71°F). This data includes MBh (Thousands of BTU/hr), S/T (Sensible/Total), ΔT (Temperature Difference), kW (Kilowatts), Amps, High Pressure (Hi PR), and Low Pressure (Lo PR). These tables are crucial for system design and performance analysis.
AHRI Ratings
The AHRI (Air-Conditioning, Heating, and Refrigeration Institute) ratings section lists certified performance data for various outdoor unit and indoor unit combinations. Key metrics include Total Cooling Capacity, Sensible Cooling Capacity, SEER (Seasonal Energy Efficiency Ratio), EER (Energy Efficiency Ratio), CFM (Cubic Feet per Minute) airflow, and the unique AHRI # for each configuration.
Wiring Diagrams
Wiring diagrams are provided for specific models (e.g., GSX130181E, GSX130(30-60)1B/C/E, GSX130(18-24)1D, GSX130611). These diagrams illustrate the factory wiring, field wiring, component codes (Contactor, Compressor, Fan Motor, etc.), color codes, and high/low voltage connections. A warning regarding high voltage is prominently displayed.
Dimensions
Physical dimensions (Width, Depth, Height) are provided in inches for each GSX13 model in a table format.
Model | W" | D" | H" |
---|---|---|---|
GSX130181E* | 23 | 23 | 25¾ |
GSX130241D* | 23 | 23 | 25¾ |
GSX130301B* | 26 | 26 | 27½ |
GSX130361C* | 29 | 29 | 28¾ |
GSX130361E* | 26 | 26 | 27½ |
GSX130421B* | 29 | 29 | 36¼ |
GSX130481B* | 29 | 29 | 36¼ |
GSX130601B* | 29 | 29 | 40 |
GSX130611A* | 35% | 35% | 38% |
Available Accessories
A table lists various optional accessories available for different GSX13 models, including Anchor Bracket Kits, Anti-Short Cycle Kits, Hard-start Kits, Freeze Protection Kits, Liquid Line Solenoid Kits, and TXV Kits.
Model | Description | GSX13 018D* | GSX13 018E* | GSX13 024C* | GSX13 024D* | GSX13 030B* | GSX13 036** | GSX13 042B* | GSX13 048B* | GSX13 060B* | GSX13 061A* |
---|---|---|---|---|---|---|---|---|---|---|---|
ABK-20 | Anchor Bracket Kit ^ | X | X | X | X | X | X | X | X | X | X |
ABK-21 | Anchor Bracket Kit ^ | X | X | ||||||||
ASC-01 | Anti-Short Cycle Kit | X | X | X | X | X | X | X | X | X | X |
CSR-U-1 | Hard-start Kit | X | X | X | X | X | X | X | X | ||
CSR-U-2 | Hard-start Kit | X | |||||||||
CSR-U-3 | Hard-start Kit | ||||||||||
FSK01A¹ | Freeze Protection Kit | X | X | X | X | X | X | X | X | X | X |
LSK02A² | Liquid Line Solenoid Kit | X | X | X | X | X | X | X | X | X | X |
TX2N4² | TXV Kit | X | X | ||||||||
TX2N4A² | TXV Kit | X | X | X | X | ||||||
TX3N4² | TXV Kit | X | |||||||||
TX5N4² | TXV Kit | X | X | X | X | X |
^ Contains 20 brackets; four brackets needed to anchor unit to pad
¹ Installed on indoor coil
² Field-installed, non-bleed, expansion valve kit. Condensing units and heat pumps with reciprocating compressors require the use of start-assist com-ponents when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.