Goodman GLXS5B High-Efficiency R-32 Split System Air Conditioner
Up to 16.5 SEER2 | 1½ To 5 Tons
Standard Features
- High-Efficiency Scroll Compressor
- Factory-installed filter drier
- Fully charged for 15' of tubing length
- 5mm diameter copper tube/ enhanced aluminum fin coil
- Sweat connection service valves with easy access to gauge ports
- Enclosed contactor
- High-pressure switch
- Ground lug connection
- Capacitors with extended life
- AHRI Certified
- ETL Listed
Cabinet Features
- Removable grille-style top design compliant with UL 60335-2-40
- Venturi for increased velocity of airflow
- Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
- Wire fan discharge grille
- Steel louver coil guard
- Top and side maintenance access
- Single-panel access to controls with space provided for field-installed accessories
- When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available).
Nomenclature
The product nomenclature is broken down as follows:
Position | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8,9 | 10 | 11 | 12 | 13 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Brand | G (Goodman® Brand) | ||||||||||||
Type | L | X | S | 5 | B | A | 36 | 1 | 0 | A | A | ||
Outdoor Type | X (Condenser) | ||||||||||||
Compressor Type | S (Single-Stage) | ||||||||||||
Efficiency (SEER2) Nominal | 5 (14.6-15.9) | 6 (16.0-16.9) | |||||||||||
Region | N (North) | ||||||||||||
Feature/Application | B (Standard) |
Product Specifications
GLXS5B A1810A* | GLXS5B A2410A* | GLXS5B A3010A* | GLXS5B A3610A* | GLXS5B A4210A* | GLXS5B A4810A* | GLXS5B A6010A* | |
---|---|---|---|---|---|---|---|
Nominal Cooling (BTU/h) | 18,000 | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 60,000 |
Decibels (dBA) | 73.0 | 69.0 | 73.0 | 71.0 | 74.0 | 75.0 | 76.0 |
Compressor RLA | 8.3 | 10.2 | 11.5 | 13.4 | 14.4 | 19.4 | 27.1 |
Compressor LRA | 44.3 | 59.3 | 66.3 | 83.3 | 112.2 | 127.7 | 178 |
Compressor Stage | Single | Single | Single | Single | Single | Single | Two |
Compressor Type | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll |
Condenser Fan Motor Type | PSC | PSC | PSC | PSC | PSC | PSC | ECM |
Condenser Fan Motor Horsepower | 1/8 | 1/6 | 1/6 | 1/6 | 1/4 | 1/4 | 1/3 |
Condenser Fan Motor FLA | 0.70 | 0.95 | 0.95 | 0.95 | 1.30 | 1.30 | 2.60 |
Refrigerant Line Size (Suction) | 3/4" | 3/4" | 3/4" | 7/8" | 1 1/8" | 1 1/8" | 1 1/8" |
Refrigerant Line Size (Liquid) | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" |
Refrigerant Charge (oz) | 54 | 65 | 87 | 88 | 141 | 138 | 167 |
Electrical Voltage-Phase | 208/230-1 | 208/230-1 | 208/230-1 | 208/230-1 | 208/230-1 | 208/230-1 | 208/230-1 |
Minimum Circuit Ampacity | 11.1 | 13.8 | 15.4 | 17.8 | 19.3 | 25.5 | 40 |
Max. Overcurrent Protection | 15 | 20 | 25 | 30 | 30 | 60 | 60 |
Min/Max Volts | 197/253 | 197/253 | 197/253 | 197/253 | 197/253 | 197/253 | 197/253 |
Electrical Conduit Size | 1½" or 3/4" | 1½" or 3/4" | 1½" or 3/4" | 1½" or 3/4" | 1½" or 3/4" | 1½" or 3/4" | 1½" or 3/4" |
Equipment Weight (LBS) | 116 | 149 | 192 | 191 | 250 | 249 | 287 |
Ship Weight (LBS) | 134 | 167 | 214 | 213 | 272 | 271 | 309 |
Expanded Cooling Data
The following tables provide detailed cooling performance data for various outdoor and indoor conditions.
IDB Airflow | Outdoor Ambient Temperature (°F) | 65 | 75 | 85 | 95 | 105 | 115 | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 63 | 67 | 71 | 59 | 63 | 67 | 71 | 59 | 63 | 67 | 71 | 59 | 63 | 67 | 71 | 59 | 63 | 67 | 71 | 59 | 63 | 67 | 71 | ||
525 | MBh | 18.1 | 18.4 | 18.9 | 19.8 | 18.0 | 18.2 | 18.8 | 19.7 | 17.5 | 17.8 | 18.3 | 19.2 | 16.8 | 17.1 | 17.6 | 18.4 | 15.8 | 16.1 | 16.6 | 17.4 | 14.9 | 15.2 | 15.7 | 16.5 |
S/T | 0.62 | 0.55 | 0.42 | 0.35 | 0.63 | 0.56 | 0.43 | 0.36 | 0.65 | 0.58 | 0.45 | 0.38 | 0.69 | 0.61 | 0.49 | 0.40 | 0.71 | 0.64 | 0.51 | 0.42 | 0.76 | 0.69 | 0.56 | 0.45 | |
ΔT | 21 | 19 | 15 | 12 | 21 | 19 | 15 | 12 | 20 | 18 | 14 | 12 | 20 | 18 | 14 | 12 | 20 | 18 | 14 | 12 | 21 | 19 | 15 | 12 | |
kW | 1.12 | 1.11 | 1.11 | 1.11 | 1.24 | 1.24 | 1.23 | 1.23 | 1.37 | 1.37 | 1.37 | 1.37 | 1.52 | 1.52 | 1.52 | 1.52 | 1.68 | 1.68 | 1.68 | 1.68 | 1.87 | 1.87 | 1.87 | 1.87 | |
Amps | 4.0 | 4.0 | 4.0 | 4.0 | 4.6 | 4.6 | 4.6 | 4.6 | 5.2 | 5.2 | 5.2 | 5.2 | 5.9 | 5.9 | 5.9 | 5.9 | 6.6 | 6.6 | 6.6 | 6.7 | 7.5 | 7.5 | 7.5 | 7.5 | |
600 | MBh | 18.5 | 18.7 | 19.3 | 20.1 | 17.8 | 18.1 | 18.6 | 19.5 | 17.0 | 17.3 | 17.8 | 18.6 | 16.1 | 16.4 | 16.9 | 17.7 | 15.2 | 15.5 | 16.0 | 16.8 | 14.3 | 14.6 | 15.1 | 15.9 |
S/T | 0.66 | 0.58 | 0.46 | 0.39 | 0.69 | 0.61 | 0.49 | 0.41 | 0.70 | 0.63 | 0.51 | 0.42 | 0.72 | 0.65 | 0.53 | 0.43 | 0.74 | 0.67 | 0.55 | 0.44 | 0.79 | 0.71 | 0.58 | 0.46 | |
ΔT | 19 | 17 | 14 | 11 | 19 | 17 | 14 | 11 | 19 | 17 | 13 | 11 | 18 | 16 | 13 | 11 | 18 | 16 | 13 | 11 | 19 | 17 | 14 | 11 | |
kW | 1.12 | 1.12 | 1.12 | 1.12 | 1.24 | 1.24 | 1.24 | 1.24 | 1.38 | 1.38 | 1.38 | 1.38 | 1.52 | 1.52 | 1.52 | 1.52 | 1.69 | 1.69 | 1.69 | 1.69 | 1.88 | 1.88 | 1.88 | 1.88 | |
Amps | 4.1 | 4.1 | 4.1 | 4.1 | 4.6 | 4.6 | 4.6 | 4.6 | 5.2 | 5.2 | 5.2 | 5.3 | 5.9 | 5.9 | 5.9 | 5.9 | 6.7 | 6.7 | 6.7 | 6.7 | 7.6 | 7.6 | 7.6 | 7.6 | |
675 | MBh | 18.9 | 19.1 | 19.7 | 20.5 | 18.3 | 18.6 | 19.1 | 20.0 | 17.4 | 17.7 | 18.2 | 19.0 | 16.5 | 16.8 | 17.3 | 18.1 | 15.6 | 15.9 | 16.4 | 17.2 | 14.7 | 15.0 | 15.5 | 16.3 |
S/T | 0.66 | 0.59 | 0.47 | 0.40 | 0.67 | 0.60 | 0.47 | 0.41 | 0.69 | 0.62 | 0.49 | 0.42 | 0.71 | 0.64 | 0.51 | 0.43 | 0.73 | 0.66 | 0.54 | 0.44 | 0.78 | 0.71 | 0.58 | 0.46 | |
ΔT | 18 | 16 | 13 | 11 | 18 | 16 | 13 | 11 | 18 | 16 | 13 | 11 | 17 | 15 | 13 | 11 | 17 | 15 | 13 | 11 | 18 | 16 | 13 | 11 | |
kW | 1.13 | 1.13 | 1.12 | 1.12 | 1.25 | 1.25 | 1.24 | 1.24 | 1.38 | 1.38 | 1.38 | 1.38 | 1.53 | 1.53 | 1.53 | 1.53 | 1.69 | 1.69 | 1.69 | 1.69 | 1.89 | 1.88 | 1.88 | 1.88 | |
Amps | 4.1 | 4.1 | 4.1 | 4.1 | 4.6 | 4.6 | 4.6 | 4.7 | 5.3 | 5.3 | 5.3 | 5.3 | 5.9 | 5.9 | 5.9 | 6.0 | 6.7 | 6.7 | 6.7 | 6.7 | 7.6 | 7.6 | 7.6 | 7.6 |
IDB: Entering Indoor Dry Bulb Temperature. Shaded area reflects ACCA (TVA) conditions. kW = Total system power. Amps = outdoor unit amps (comp.+fan). High and low pressures are measured at the liquid and suction service valves.
Dimensions
Model | W" | D" | H" |
---|---|---|---|
GLXS5BA1810A* | 26 | 26 | 27 |
GLXS5BA2410A* | 29 | 29 | 32 |
GLXS5BA3010A* | 35% | 35% | 39% |
GLXS5BA3610A* | 35% | 35% | 39% |
GLXS5BA4210A* | 35% | 35% | 36% |
GLXS5BA4810A* | 35% | 35% | 36% |
GLXS5BA6010A* | 35% | 35% | 41% |
*Note: All Dimensions (W, D, H) are for reference only.
Wiring Diagram
The wiring diagram illustrates the electrical connections for the GLXS5B series, detailing component codes, color codes, and wiring types (factory, high voltage, low voltage, optional high voltage, field wiring). Key components include the control box, contactor, compressor, fan motor, various switches (high pressure, crankcase heater), and capacitors. The diagram also includes important notes regarding power supply, conductor types, and control box connections, emphasizing safety precautions for high voltage.
Accessories
Model | Description | GLXS5B A1810A* | GLXS5B A2410A* | GLXS5B A3010A* | GLXS5B A3610A* | GLXS5B A4210A* | GLXS5B A4810A* | GLXS5B A6010A* |
---|---|---|---|---|---|---|---|---|
016R00128 | Neutral Circular Cap | X | X | X | X | X | X | X |
ABK-20 | Anchor Bracket Kit ^ | X | X | X | X | X | X | X |
ASC01A | Anti-Short Cycle Kit | X | X | X | X | X | X | X |
CSR-U-1 | Hard-start Kit | X | X | X | X | |||
CSR-U-2 | Hard-start Kit | X | X | X | X | |||
CSR-U-3 | Hard-start Kit | X | X | X | ||||
Factory Installed Crank Case Heater | X | X | X | |||||
0163R00006 | Crank Case Heater | X | X | X | X | |||
0130M00106 | CCH Temp Switch | X | X | X | X | |||
FSK01A¹ | Freeze Protection Kit | X | X | X | X | X | X | X |
LSK02A² | Liquid Line Solenoid Kit | X | X | X | X | X | X | X |
LAKT01 | Low-Ambient Kit | X | X | X | X | X | X | |
0130R00000S | Low-Pressure Switch Kit | X | X | X | X | X | X | X |
^ Contains 20 brackets; four brackets needed to anchor unit to pad. ¹ Installed on indoor coil. ² Condensing units and heat pumps with reciprocating or rotary compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. The TXV should always be sized based on the tonnage of the outdoor unit.
All AHRI system ratings are accessible in the System Configurator tool via PartnerLink.