Mini Digital Clamp-On Multimeter

Operating Instruction

1. SAFETY INFORMATION

This Mini-sized digital clamp multimeter has been designed according to IEC61010 oncoming electronic measuring instruments with an over voltage category (CAT II 600V) and Pollution degree 2.

WARNING

To avoid possible electric shock or personal injury, follow these Guidelines:

2. INTRODUCTION

This manual provides all safety information, operation instruction, specifications and maintenance for the meter, which is compact, handheld, and battery operated.

This instrument performs AC/DC voltage, DC/AC Current, Resistance, Audible Continuity, Diode, Temperature measurements and Non-Contact ACV Detect (NCV) as well as Capacitance, Hz etc.

It is an auto ranging DMM with AC/DC current clamp meter function.

3. CAUTION

To avoid damage to the meter, don't apply input which exceeds the limit shown below:

Function Input Limits
DCV/ACV 600V DC or 600V rms AC
250V DC or rms AC
250V DC or rms AC

4. GENERAL CHARACTERISTICS

5. PANEL DESCRIPTION

1. Transformer jaw

2. Clamp trigger

3. LCD backlight and value hold buttons

4. LCD Display

5. COM Input Terminal

6. NCV LED Indication

7. Manual range switching

8. Function rotated switch

9. Function Select button

10. V, Ω, °C, Hz Input Terminal

6. SPECIFICATIONS

Accuracy is guaranteed for 1 year 23° C+5° C less than 75%RH

6-1. AC VOLTAGE (Auto ranging)

Range Resolution Accuracy
4V 1mV ± (1.5% + 3d)
40V 10mV
400V 100mV
600V 1V

Input Impedance: more than 10MΩ; Frequency Range:40 to 400Hz.

6-2. DC VOLTAGE (Auto ranging)

Range Resolution Accuracy
400MV 0.1MV ± (1.5% + 5d)
4V 1mV ± (1.0% + 3d)
40V 10mV
400V 100mV
600V 1V

Input Impedance: more than 10MΩ

6-3. RESISTANCE (Auto Ranging)

Range Resolution Accuracy
400Ω 0.1Ω ± (1.2% + 3d)
4ΚΩ 8
40ΚΩ 10Ω
400ΚΩ 100Ω
4ΜΩ 1ΚΩ ± (1.5% +5d)
40ΜΩ 10ΚΩ

6-4. AC CURRENT (Auto ranging)

Range Resolution Accuracy
40A 10mA ± (2.5% + 3d)
400A 100mA

Measuring voltage drop: 200mV; Frequency Range: 40 to 400Hz.

6-5. FREQUENCY (Auto ranging)

Range Resolution Accuracy
10Hz~400kHz 1Hz ± (1.0% +5d)
400kHz~4MHz 1kHz (2.0% +5d)

Input Voltage Limit: Max. 250V (<4M Hz).

6-6. CAPACITANCE (Auto ranging)

Range Resolution Accuracy
1nF~4 µF 0.01η~0.01 µF ± (2.5% + 10d)
4 μ F~400uF 0.1uF (4.0% +20d)
4mF 1uF (5.0% +30d)

6-7. TEMPERATURE (only 3269)

Range Resolution Accuracy
0~750°C 1°C ± (2.0% +1°C)
32~1382°F 1°F ± (2.5% + 1°C)

0~400°C, 400~750°C

32~752°F, 752~1382°F

6-8. Non-Contact AC VOLTAGE Detection (NCV)

One Special Front LED Lighting for indication of over AC100V source without directly contact.

7. CONTROL BUTTON DESCRIPTION

7-1. HOLD AND LCD BACKLIT BUTTON (H/

7-2. Manual range selection (REL)

Press this key briefly for manual range selection;

Press and hold for about 2 seconds to deactivate.

7-3. Function select button (SET)

8. OPERATION INSTRUCTION.

8-1. AC/DC VOLATAGE MEASUREMENT

  1. Connect the BLACK test lead to the COM jack and the RED to the V/O jack.
  2. Set the function switch at ACV or DCV position, connect test leads across the source or load under measurement.
  3. Read LCD display. The polarity of RED test lead will be indicated when making a DC measurement.

8-2. RESISTANCE MEASUREMENT

  1. Connect the BLACK test lead to the COM jack and the RED to the V/Ω jack. (NOTE: The polarity of the RED lead is positive "+" and the BLACK is negative "-").
  2. Set the function switch at position, and then Push "SEL" button to select Ω Mode, then the symbol "Ω" is shown on LCD.
  3. Connect test leads across the resistance under measurement, and then get the test readings on LCD.

NOTE:

8-3. AC CURRENT MEASUREMENT

  1. Set Function/Range Switch to the AC range (s).
  2. Press the trigger to open the transformer jaws. And clamp one conductor only it is impossible to make measurements when two or three conductors are clamped at the same time.
  3. Display reading is showing the conductor AC current.

8-4. AUDIBLE CONTINUITY/DIODE TEST

  1. Connect the BLACK test lead to the COM jack and the RED to the V/ jack.
  2. Set the function switch at position and push the button "SEL" to select continuity or diode test mode. Then the symbol " or " is shown on LCD.
  3. In continuity test, if the circuit resistance under test is lower than 50Ω, built-in buzzer will sound.
  4. If diode test mode is selected, connect the RED and BLACK test leads to anode and cathodes of the diode under test separately. The forward voltage drop of diode will be displayed.

8-5. FREQUENCY TEST

  1. Connect the BLACK test lead to the COM jack and the RED test lead to the V/ Hz jack.
  2. Put the range selector at "Hz" position, and connect the test leads across the resistance under measurement.
  3. Take the reading from LCD.

Note: When test the high Frequency > 1MHz, the input Voltage must be less than 10V for getting the accurate value.

8-6. CAPACITANCE MEASUREMENT

  1. Connect the BLACK test lead to the COM jack and the RED test lead to the V/Ω jack. (Note: The polarity of the RED test lead is "+")
  2. Put the range selector at position, and connect the test leads across the Capacitor under measurement. Disconnect the capacitor with the outer power source.
  3. Check if the "F" mark on the LCD. If not, push the "SET" button one or more times until shown.
  4. Take the reading from LCD. When test the large capacitor, it's normal to take more time for getting the values on LCD.

NOTE: Make sure of discharging all the capacitor's electricity completely before measurements.

8-7. TEMPERATURE MEASUREMENT(only 3269)

  1. Set the function range switch at the °C position.
  2. Make sure the polarity of the thermocouple correct, put the Black pin terminal of the K-type thermocouple sensor into the COM jack and the RED pin terminal into the V/Ω/°C jack.
  3. Set the working end (testing end) on or inside the object under test.
  4. The value of the temperature is shown on the display in degree centigrade (°C).

NOTE:

8-8. Non-Contact AC VOLTAGE Detection (NCV)

  1. Set the function range switch at the NCV position. Then the NCV indicating LED light is flashing.
  2. Take the clamp jaw close to the AC signal.
  3. Then the NCV indicating LED is constantly flash and the Beeper sounding at the same time.once ACV> 100V.

NOTE: Don't try to contact the testing place with this tester. No display on LCD at this range.

9. BATTERY REPLACEMENT

If the sign "" appears on the display, it indicates battery should be replaced. Remove screws and open the back case, replace the exhausted batteries with new ones (AAA 1.5V *2pc or equivalent).

PDF preview unavailable. Download the PDF instead.

Saf2b5554c11e494a894cfbe9e07fb922H

Related Documents

Preview ANENG ST181 Mini Digital Clamp-On Multimeter Operation Manual
Operation manual for the ANENG ST181 Mini Digital Clamp-On Multimeter, covering safety, panel description, specifications, and detailed instructions for various electrical measurements including voltage, current, resistance, capacitance, frequency, and temperature.
Preview ANENG PN200 Multifunctional Clamp Ammeter: Features, Specifications, and Usage
Explore the ANENG PN200, a versatile AC/DC clamp ammeter for electrical testing. Learn about its functions including current, voltage, resistance, capacitance, frequency, NCV detection, and its key specifications and accessories.
Preview ANENG ST180 4000 Counts Digital AC Current Clamp Multimeter Specifications and Features
Detailed specifications and features of the ANENG ST180, a 4000 counts digital AC current clamp multimeter. Includes measurements for AC/DC voltage, AC current, resistance, capacitance, frequency, and temperature.
Preview Intelligent Digital Clamp Multimeter User Manual
User manual for the Intelligent Digital Clamp Multimeter, covering safety information, specifications, operation guide, maintenance, and accessories. Learn how to safely and effectively use the device for various electrical measurements.
Preview ANENG M127/M128 Multimeter User Manual
Comprehensive user manual for the ANENG M127 and M128 portable smart multimeters, detailing features, functions, and operating instructions.
Preview ANENG 621A Intelligent Digital Multimeter User Manual
User manual for the ANENG 621A intelligent digital multimeter, detailing its features, technical specifications, operating instructions, and maintenance.
Preview ANENG ST181 Clamp Multimeter Specifications and Features
Detailed specifications and features of the ANENG ST181 clamp multimeter, a digital AC/DC current meter suitable for electrical equipment testing and maintenance.
Preview Aneng A3008 Pro: Smart Pen Digital Multimeter with TrueRMS and NCV
Discover the Aneng A3008 Pro, a compact and intelligent pen-style digital multimeter. Featuring TrueRMS, NCV detection, and a wide range of measurement capabilities including voltage, resistance, capacitance, and frequency. Ideal for professionals and hobbyists.