Pioneer Inverter Air Conditioner Indoor/Outdoor Unit Disassembly Manual

Inverter Air Conditioner Indoor/Outdoor Units Disassembly Manual

Models: RYT009GLSI24RL | RYT012GLSI24RL | RYT018GLSI24RL | RYT024GLSI24RL

Duct (IDU) Disassembly

Indoor Unit Model Numbers: RT009GLSILCFHG | RT012GLSILCFHG | RT018GLSILCFHG | RT024GLSILSFHG

  1. Before disassembly

    Prepare for disassembly.

  2. Disassemble the filter assembly

    A. Disassemble the filter assembly.

    B. Remove the filter.

  3. Disassemble the base part and air return plate

    A. Remove the base part by unfixing the screws on the left and right side panels, as well as the center partition.

    B. Remove the screws between the air return plate, left side plate, and electric control box. Then, remove the air return plate.

    C. Remove the Wi-Fi fixing cover and take the USB connection cable out.

  4. Disassemble the front panel assembly

    Unfix the screws on the front panel and remove the assembly.

  5. Remove the electrical box cover and hooks

    A. Unfix the screws on the electrical box cover and remove the cover.

    B. Unfix the screws on the hooks, then remove the hooks.

  6. Remove the electric control box assembly

    Unfix the screws on the electric control box, then remove the electric control box.

  7. Remove the water tray assembly

    A. Remove the base plate.

    B. Lift the drain nozzles up on both sides to take the water tray out.

  8. Disassemble the right side plate and drainage mounting assembly

    A. Unfix the screws between the right side plate, evaporator end plate, top plate, and drain mounting assembly. Then, remove the right side plate.

    B. Remove the drain nozzle on the drain mounting assembly, then take the assembly out.

  9. Remove the water pump assembly, evaporator module, and left side panel parts

    A. Unfix the screws on the water pump assembly and center divider. Then, remove the water pump assembly.

    B. Unfix the screws on the evaporator module and left side panel assembly. Then, take the left side panel out.

    C. Unfix the screws on the left side panel part, top panel, and center partition. Remove the left side panel part.

  10. Remove the centrifugal fan volute assembly and DC motor

    Remove the motor limit clasp, then take the volute assembly and DC motor out in the direction shown in the reference photo.

  11. Remove the center divider assembly

    Unfix the screws on the center divider assembly and top cover. Remove the center divider.

ODU Disassembly

Outdoor Unit Model Numbers: YN009GLSI24RPG | YN012GLSI24RPG | YN018GLSI24RPG | YN024GLSI24RPG

  1. Before disassembly

    Prepare for disassembly.

  2. Remove the PCB cover, valve cover, and top cover

    A. 1). Unfix 1 screw on the PCB cover, then you can remove the cover from the unit. 2). Unfix 1 screw on the valve cover, and then you can take it out.

    B. Unfix the screws on the top/left/right plates, and then you can take the top cover off.

  3. Disassemble the fan guard and front panel

    A. Remove the grille screws from the front panel, then take out the grille.

    B. 1). Unfix the screws on the front panel of the fan guard. 2). Separate the ODU middle plate and base plate. Lift the front panel so you can take it out from the unit.

  4. Disassemble the left and right plate

    A. Unfix the screws on the right plate, electric box assembly, valve plate, and base plate. You can then remove the right plate.

    B. Unfix the screws on the left plate, base plate, and condenser plate. You can then take the left plate out.

  5. Disassemble the axis fan blade

    A. Unscrew the fan blade nut. Remove the blade.

  6. Disassemble the electric box

    A. Unfix the screws on the electric box and motor supporter. Loosen the wiring clamp, then you can take the control box out.

  7. Remove the noise cotton

    A. Take the cotton out, as shown in the picture.

  8. Disassemble the separate plate

    A. Unfix the screw on the separate plate and unit, then take it out.

  9. Disassemble the 2-way and 3-way valve

    A. Unfix the screws on the valve plate and base. You can take the 2-way and 3-way valve out by welding.

    Note: 1). Welding can only occur while there is no gas in the unit. 2). Pay attention to the fire to prevent any injury.

  10. Disassemble the 4-way valve assembly

    A. Remove the 4-way valve from the system by welding. Ensure there is no damage to the compressor, nameplate, etc.

  11. Disassemble the compressor

    A. Unscrew the nuts and remove the compressor.

  12. Remove the fan motor and fan supporter

    A. Unfix the screws on the fan motor and supporter, then remove the supporter of the base plate.

    Note: Pay attention to the motor wiring. It can't be taken out by force.

Company Information

The design and specifications of this product are subject to change without prior notice as development continues. Consult with the sales agency or manufacturer for details. Refer to the equipment nameplate for all other applicable specifications.

PIONEER is a registered trademark of Parker Davis HVAC International, LLC.

Parker Davis HVAC International
7290 NW 77 Court, Miami, FL 33166 - USA
Tel: (305) 513-4488
Fax: (305) 513-4499
E-mail: info@pdhvac.com
Website: www.pdhvac.com

Pioneer product line, parts, and supplies are available online for convenient ordering at:

Scan the below code to visit our support page where you can find more installation materials:

[QR Code Placeholder - QR codes are excluded]

Copyright © Parker Davis HVAC International, LLC. All rights reserved.

Models: RYT009GLSI24RL, RYT018GLSI24RL, RYT012GLSI24RL, RYT024GLSI24RL, RYT009GLSI24RL Inverter Air Conditioner, RYT009GLSI24RL, Inverter Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 10 Pages, 2.68MB

PDF preview unavailable. Download the PDF instead.

RYT24-DISM-2501

References

macOS 版本13.5(版号22G74) Quartz PDFContext

Related Documents

Preview Pioneer RYT-24 Inverter Series Air Conditioner Parts Diagrams and Lists
Comprehensive parts diagrams and lists for Pioneer RYT-24 Inverter Series Ductable Mini Split System Air Conditioners and Heat Pumps, including models RYT009, RYT012, RYT018, and RYT024.
Preview Pioneer Inverter Air Conditioner Indoor/Outdoor Unit Disassembly Manual
Detailed disassembly instructions for Pioneer Inverter Air Conditioner Indoor (Cassette) and Outdoor (ODU) units, covering models CYT, CT, and YN series.
Preview Pioneer Inverter Air Conditioner Indoor/Outdoor Unit Disassembly Manual
Comprehensive disassembly guide for Pioneer Inverter Air Conditioner Indoor (IDU) and Outdoor (ODU) units, covering models UYT018GLSI24RL, UYT024GLSI24RL, UT018GLSILCFHG, UT024GLSILSFHG, YN018GLSI24RPG, and YN024GLSI24RPG. Provides step-by-step instructions with textual descriptions of visual aids for safe and effective disassembly.
Preview PIONEER RT018GLSI24RPG Ceiling-Concealed Ducted Inverter Heat Pump - Technical Specifications and Features
Detailed submittal sheet for the PIONEER RT018GLSI24RPG Ceiling-Concealed Ducted Inverter Heat Pump, including cooling and heating performance, electrical specifications, dimensions, outstanding features, and available accessories.
Preview PIONEER Quint (5) Circuit Ducted Inverter Heat Pump System Submittal Sheet & Specifications
Detailed submittal sheet and specifications for the PIONEER Quint (5) Circuit Ducted Inverter Heat Pump System, including cooling/heating performance, electrical data, dimensional information, and compatible indoor units.
Preview Parker Davis Pioneer YN030GLSI24M3G Triple Circuit Ducted Inverter Heat Pump Submittal Sheet
Technical submittal sheet for the Parker Davis Pioneer YN030GLSI24M3G multi-zone ducted inverter heat pump system. Details cooling/heating performance, electrical specs, piping, dimensions for condenser and indoor units (RT009, RT012, RT018), features, and warranty.
Preview Pioneer Inverter Air Conditioner Service Manual - WYT Series
Service manual for Pioneer Inverter Air Conditioners (WYT009GLSI25RH, WYT012GLSI25RH, WYT018GLSI25RH, WYT024GLSI25RH). Covers technical specifications, installation, maintenance, and troubleshooting.
Preview Pioneer YN020GLSI24M2G Dual Circuit Ducted Inverter Heat Pump System Submittal Sheet
Detailed submittal sheet for the Pioneer YN020GLSI24M2G Dual Circuit Ducted Inverter Heat Pump Set, including performance specifications, dimensions, electrical data, and compatible indoor units (RT009GLSILCFHG, RT012GLSILCFHG).