PIONEER Submittal Sheet
Ceiling-Concealed Ducted Inverter Heat Pump
Model Numbers: RT018GLSILCFHG / YN018GLSI24RPG
System Full Set Model: RYT018GLSI24RL
AHRI Reference Number: 217048764
Cooling Mode Performance
Rated Cooling | 17,000 BTU/hr |
Ambient Range | 5°F ~ 131°F |
SEER Rating | 21.0 BTU/W·h |
EER Rating | 11.7 BTU/W·h |
Note: 100% Capacity @ Indoor DB 80°F/WB 67°F
Heating Mode Performance
Rated Heating | 18,000 BTU/hr |
Ambient Range | -13°F ~ 86°F |
HSPF2 IV (V) | 8.1 (7.2) BTU/W·h |
COP | 2.9 (W/W) |
Note: High Heat (47°F) = 18,000 BTU / Low Heat (17°F) =11,000 BTU / COP (5°F) = 1.8
Electrical Information
Cooling | Heating | |
---|---|---|
Rated Input (W) | 1,450 | 1,805 |
Rated Current (A) | 6.3 | 7.8 |
Breaker Needed | 20A (Double-Pole) | |
Power Supply | 208~230V, 1Ph, 60Hz |
Piping and Refrigerant
Liquid Line (OD) | 1/4" |
Suction Line (OD) | 1/2" |
Refrigerant Precharge | R454b (Selectable Lineset) |
Max Length/Height Diff. | 65 ft. / 50 ft. |
This combination is Energy-Star certified. ?
Interior Unit (Air Handler) Specifications
Type | Heat Pump |
Sound Level (dBA) | 41 (Hi) / 38 (Med) / 36 (Lo) |
Auto Air Circulation | 2-Way Louver (Up-Down + Left-Right) |
Dimensions (WDH) | 35"-1/2 x 19"-1/4 x 7"-7/8 |
Weight (lbs) | 39.7 |
Exterior Unit (Condenser) Specifications
Sound Level (dBA) | 53 |
Recommended Room Size | 500~750 Sq. ft. |
Minimum Room Size | 51 Sq. ft. |
Compressor | Inverter-Driven Rotary |
Dimensions (WDH) | 36"-1/2 x 15" x 27"-1/2 |
Weight (lbs) | 90.4 |
Dimensional Data - Air Handler
The diagrams illustrate the air handler unit from the Supply Side, Inlet Side, Side View, Above View, and Below View, showing various dimensions labeled A through M. A table provides the specific measurements for these dimensions in both inches and millimeters.
Overall Air Handler Dimensions
Dimension | Value (in) | Value (mm) |
---|---|---|
A | 36-1/4 | 920.8 |
B | 7-7/8 | 200 |
C | 19-3/8 | 492.1 |
D | 17-3/4 | 450.9 |
E | 1-3/4 | 44.5 |
F | 28-3/4 | 730.3 |
G | 1/8 | 3.2 |
H | 5-1/2 | 139.7 |
I | 32-1/4 | 819.2 |
J | 7-3/8 | 187.3 |
K | 1-3/8 | 34.9 |
L | 37-3/4 | 958.9 |
M | 11-3/4 | 298.5 |
Clearance Requirements
Air Inlet requires at least 40 inches (100 cm) clearance. Side View requires at least 10 inches (25 cm) clearance. Front View requires at least 20 inches (50 cm) clearance.
Dimensional Data - Condenser Unit
The diagrams illustrate the condenser unit from the Underside View, Front View, and Side View, showing dimensions labeled A through H. A table provides the specific measurements for these dimensions in both inches and millimeters for the YN018GLSI24RPG model.
Model | A (mm) | A (in) | B (mm) | B (in) | C (mm) | C (in) | D (mm) | D (in) | E (mm) | E (in) | F (mm) | F (in) | G (mm) | G (in) | H (mm) | H (in) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YN018GLSI24RPG | 845 | 33-1/4" | 699 | 27-1/2" | 326 | 12-7/8" | 586 | 23-1/8" | 375 | 14-3/4" | 348 | 13-3/4" | 55 | 2-1/8" | 55.9 | 2-1/4" |
Warranty Information and Length
Complete warranty details are available with the vendor or online at https://www.pdhvac.com/support/warranty/. This high-quality system is eligible for up to a 5-year limited warranty on the compressor, and 5 years on other internal parts. To qualify for this warranty, the system must be installed within 90 days and registered properly. All other installations that are unregistered qualify for only 1-year parts/compressor warranty.
Outstanding Features
- LED Display
- Energy Saving
- Ultra-Thin Design
- Dual Drain Options
- Customizable Timer
- Eco-Friendly Refrigerant
- Whisper-Quiet Operation
- Power Loss Memory Recovery
Available Accessories
Part Number | Description |
---|---|
IKT-LCVR4P-KIT | Decorative PVC Line Cover Kit |
IKT-LNBR-1/4-3/8 | BendAid Flexible Easy Bender Kit |
BRK-FRM-C-2P | Folding Mounting Bracket w/ Leveler |
IKT-UVL32UL-AG | UVC Bacterial Disinfection Kit |
IKT-SURPRK-DV2 | Ultimate Surge and Power Protection |