MAUL Scale Operating Instructions
Battery
The scale comes with a standard CR2032 battery. The battery compartment is on the base of the scales. Please note polarity marking. Before using the scales remove the plastic protection.
Positioning the scales
Please ensure that the scales is in a horizontal position.
Weighing (ON)
After switching on the scales with the ,,ON/OFF/TARE" key, ,,88888" appears in the display. Please wait until zero appears. Then place the weight on to the scales and read off the weight.
Net weighing (TARE)
Place an empty container (i.e. first weight) on to the scales and then subtract this weight by pressing the key until zero appears. Fill the container (i.e. add second weight to the scales). Only the additional weight is indicated in the display.
Switch off (OFF)
Press the key ,,ON/OFF/TARE" until the display disappears. Automatic switch-off will occur after approx. 2 minutes, if no change of weight occurs in this time.
Switching the weight units g or oz
The scales can show the weight value in g or oz. Press the ,,UNIT" key when the scales is turned on. Press the key again to change the weighing unit.
User calibration
If needed, the scales can be recalibrated by the user. Switch the scales on and set the measurement to "g". Press the key "ON/OFF/TARE" rapidly four times in a row and hold. A number appears with or without a sign. Press the "ON/OFF/TARE" key again. "ZERO" appears, followed by "2000". Now place a 2kg calibrated weight on the scales and press the "ON/OFF/TARE" key. "CAL" first appears on the display, then "PASS" and finally "2000g". The scales has been recalibrated. Important: the scales must not be exposed to any vibration or draft during the calibration.
Explanation of the special symbols
- 1. Switching on: After pressing the ,,ON/OFF/TARE"- key all symbols appear. You can check whether all segments are clearly shown on the display. Zero indicates that the scales is ready for operation.
- 2. Negative value: Press the ,,ON/OFF/TARE"- key once again.
- 3. Overload: If the weight exceeds the total weighing capacity of the scales, ,,O-Ld" appears in the display.
- 4. Energy Supply: If appears on the display, the battery need to be changed.
Precision
This device corresponds to requirements stipulated in 2014/31/EU. Every scale has been carefully calibrated and controlled during the production process. The tolerance is ± 0,5% ± 1 digit (at Temperatures between +5° and +35° C). Incorrect display values due to damage attributable to improper handling, mechanical damage or malfunction is exempt from liability. Damages due to faults are also exempt from the guarantee. No liability is accepted for consequential damages or losses by the buyer or the user.
Compliance
This device complies with the requirements of EC Directive 2014/31/EU. Note: Unusual electro-magnetic influences (jammers in the immediate vicinity) may affect the display value. After the end of the interference period, the product can be used again as intended. These scales cannot be used for official metrology.