Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System
Submittal Data Sheet
Job Name: [Not Specified]
Tag#: [Not Specified]
Efficiency
Parameter | Cooling | Heating | ||
---|---|---|---|---|
SEER | EER | HSPF | COP | |
Value | 18 | 12.5 | 9.0 | 3.50 |
Warranty Information
Complete warranty details are available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If the product is installed in a commercial application, the limited warranty period is 5 years.
Performance
Cooling (Btu/hr)
Parameter | Value |
---|---|
Rated (Min/Max) | 21,200 (5,500 / 24,000) |
Sensible @ AHRI | 15,760 |
Moisture Removal gal/h | 1.2 |
Standard Operating Range | 50°F – 115°F |
Extended Operating Range* | -4°F – 115°F |
Rated Cooling Conditions: | Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB |
*With field settings and wind baffle
Heating (Btu/hr)
Parameter | Value |
---|---|
1: @ 47° Rated (Min/Max) | 24,000 (5,800 / 27,600) |
2: @ 17° Rated | 14,400 |
3: @ 5° | 10,720 |
Operating Range | 5°F – 65°F |
1: Rated Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB |
2: Rated Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB |
3: Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB |
Indoor Specifications
Cooling
Airflow Rate (cfm) | H | M | L | SL |
---|---|---|---|---|
Value | 713 | 579 | 512 | 403 |
Sound (dBA) | H | M | L | SL |
---|---|---|---|---|
Value | 53 | 45 | 39 | 34 |
Heating
Airflow Rate (cfm) | H | M | L | SL |
---|---|---|---|---|
Value | 745 | 604 | 470 | 420 |
Sound (dBA) | H | M | L | SL |
---|---|---|---|---|
Value | 53 | 43 | 37 | 34 |
Dimensions (H x W x D) (in)
11-5/8 x 39 x 10-3/8
Weight (Lbs)
27
Outdoor Specifications
Compressor | Hermetically Sealed Swing Type |
---|---|
Refrigerant | R-410A |
Factory Charge (Lbs) | 3.20 |
Refrigerant Oil | PVE (FVC50K) |
Cooling
Airflow Rate (cfm) | H | SL |
---|---|---|
Value | 2,101 | 1,762 |
Heating
Airflow Rate (cfm) | H | SL |
---|---|---|
Value | 1,893 | 1,585 |
Sound Pressure Level (dBA)
55
Dimensions (H x W x D) (in)
28-5/16 x 34-1/4 x 12-5/8
Weight (Lbs)
108
Electrical
Parameter | 208/60/1 | 230/60/1 |
---|---|---|
System MCA | 18.3 | 18.3 |
System MFA | 20 | 20 |
Compressor RLA | 12.0 | 12.0 |
Outdoor fan motor FLA | .38 | .38 |
Outdoor fan motor W | 58 | 58 |
Indoor fan motor FLA | .30 | .30 |
Indoor fan motor W | 46 | 46 |
MFA: Max. fuse amps, MCA: Min. circuit amps (A), FLA: Full load amps (A), RLA: Rated load amps (A), W: Fan motor rated output (W)
Piping
Parameter | Value |
---|---|
Liquid (in) | 1/4 |
Gas (in) | 5/8 |
Drain (in) | 5/8 |
Max. Interunit Piping Length (ft) | 98.4 |
Max. Interunit Height Difference (ft) | 65.625 |
Chargeless (ft) | 32.8 |
Additional Charge of Refrigerant (oz/ft) | .21 |
Dimensional Data - Indoor Unit
The indoor unit is depicted with its wireless remote controller (ARC480A8). Diagrams illustrate the unit's front, side, and bottom views, highlighting features such as the front grille with adjustable flaps for airflow direction (up/down automatic, right/left manual), signal receiver, operation lamp, timer lamp, room temperature thermistor, and indoor ON/OFF switch. The terminal block with earth terminal is shown inside. Piping connections for liquid (1/4 inch) and gas (5/8 inch) are indicated, along with the drain hose connection (I.D. 9/16 inch, O.D. 5/8 inch). Dimensions are provided in inches (mm) for various features and mounting locations, including the wall hole for embedded piping.
Dimensional Data - Outdoor Unit
The outdoor unit is shown with its handles and mounting points. Diagrams detail the unit's dimensions and required clearances. Key features include the brand name plate, ground terminal, service port, stop valve covers, terminal strip cover, electric wire intake, and outdoor air thermistor. Piping connections for liquid (1/4 inch) and gas (5/8 inch) stop valves are illustrated, along with the drain outlet. Minimum space requirements for air passage and maintenance are specified.
Optional Accessories
Indoor Unit Accessories
Included | Part Number | Description |
---|---|---|
BRP072A43 | Wireless Interface Adapter (S21 Adapter Included) | |
BRC944B2-A08 | Wired Remote Controller kit (Adaptor Required) | |
BRCW901A08 | Wired Remote Controller Cable – 25ft (Included in above kit) | |
BRCW901A03 | Wired Remote Controller Cable – 10ft | |
KRP980B2 | Adaptor for wired remote controller (18 & 24) | |
KAF970A45 | Titanium apatite photocatalytic air-purifying filter WITH frame | |
KAF970A46 | Titanium apatite photocatalytic air-purifying filter WITHOUT frame | |
DACA-CP1-1 | Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) | |
DACA-CP4-1 | External Condensate Pump | |
KRP928BB2S + KRP980B2 | Interface adaptor for DIII-NET |
Outdoor Unit Accessories
Included | Part Number | Description |
---|---|---|
DACA-WB-1 | Powder-Coated Wall-Mounted Bracket | |
KPW063B4 | Air direction adjustment grille (18 & 24) | |
KEH063A4E | Daikin BML Drain Pan Heater Large RX18,24 & RXN18,24 | |
KKG063A42 | Back protection wire net (18 & 24) | |
KKP937A4 | Drain Plug for OD Unit |
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)
Submittal Revision Date: December 2019